ELE05-00732
| Final | 8/4/2005 | 8/4/2005 | 8/4/2005 4:26:51 PM | P | CANC |
|
|
richard; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called electrical contractor he is ok but general needs to get his building permits squared away so I can sign the right card for the job
|
ELE05-02821
| Permanent Service | 8/3/2005 | 8/4/2005 | 8/4/2005 3:38:28 PM | A | FAIL |
|
|
ROWDY ###-####///ASAP PLEASE cor. posted met contractor, told him on 08-03-05 what was required for working space,, 110.26 (A)thur(F) dedicated space
|
ELE05-02832
| Rough-In Permanent Service | 8/4/2005 | 8/4/2005 | 8/4/2005 3:06:08 PM | P | PASS |
|
|
rick ###-#### r/i ok called rick about outlet for fixed panel of back slider p/s u/g new ok
|
ELE05-02819
| Conference | 8/3/2005 | 8/4/2005 | 8/4/2005 2:09:56 PM | P | DONE |
|
|
james ###-#### ok
|
ELE05-01404
| Permanent Service | 8/4/2005 | 8/4/2005 | 8/4/2005 1:23:16 PM | P | PASS |
|
|
eric; Phone #: ###-#### Internet Inspection Request from: Barbara Moore p/s u/g new ok
|
ELE05-02686
| Final | 8/4/2005 | 8/4/2005 | 8/4/2005 12:43:10 PM | P | NR |
|
|
yanke energy//please call with results at ###-#### kevin; Phone #: ###-#### Internet Inspection Request from: Barbara Moore no power yet could not final called
|
ELE05-01763
| Final | 8/3/2005 | 8/4/2005 | 8/4/2005 10:44:55 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 8/3/2005 at 4:33:54 PM. Contact: ###-####. cor. posted called 210.52(C) outlet spacing right of range, check for box fill cutin boxes island
|
ELE05-02829
| Temporary Service | 8/3/2005 | 8/4/2005 | 8/4/2005 10:12:28 AM | A | PASS |
|
|
###-#### JEFF OR CHRIS t/s u/g new ok
|
ELE05-02358
| Final | 8/3/2005 | 8/4/2005 | 8/4/2005 9:48:47 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Tyler Bowen ok card signed
|
ELE05-02597
| Final | 8/3/2005 | 8/4/2005 | 8/4/2005 9:08:41 AM | A | PASS |
|
|
heath; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa ok card signed
|
ELE05-02816
| Electrical Rough-In | 8/3/2005 | 8/4/2005 | 8/4/2005 8:33:02 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: steven sewell cor. do not cover posted called 300.4 nail plates and 11/4", 210.52(A) outlet spacing new part, old where walls are changed, acces to j tub, 250.102(C) needs #4 bond to nipple, 314.16 box fill, make sure of clearence by upstairs window service drop
|
ELE05-02790
| Temporary Service | 8/3/2005 | 8/4/2005 | 8/4/2005 7:41:43 AM | A | PASS |
|
|
JUSTIN; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles t/s o/h new ok
|