ELE13-01367
| ELE-Aging Inspection | 8/4/2015 | 8/4/2015 | 8/6/2015 7:40:05 AM | | CANC |
|
|
too busy
|
ELE12-01653
| ELE-Aging Inspection | 8/4/2015 | 8/4/2015 | 8/4/2015 3:39:28 PM | | DONE |
|
|
Waiting for contractor to schedule
|
ELE15-02407
| Rough-In Permanent Service | 8/3/2015 | 8/4/2015 | 8/4/2015 3:31:34 PM | P | PASS |
|
|
turn north on Charlotte off of victory. take next left and then the next right is Kylee pl. Phone #: ###-#### Inspection requested via web by Brian Hughes Rough in ok cover p/s u/g n ok
|
ELE15-00262
| Final | 8/4/2015 | 8/4/2015 | 8/4/2015 2:48:29 PM | P | PASS |
|
|
Adam Wright Contact Final Phone #: ###-#### Inspection requested via web by April Brown Final ok
|
ELE15-01203
| Final | 8/4/2015 | 8/4/2015 | 8/4/2015 2:06:09 PM | P | PASS |
|
|
Mike Phone #: ###-#### Corrections made. Final ok
|
ELE14-03151
| Final | 8/4/2015 | 8/4/2015 | 8/4/2015 1:52:36 PM | P | NH |
|
|
Adam Wright Contact Final Phone #: ###-#### Inspection requested via web by April Brown Gates locked contact to schedule with city employee with key.
|
ELE14-01066
| Electrical Rough-In | 8/4/2015 | 8/4/2015 | 8/4/2015 1:44:32 PM | P | PASS |
|
|
hard lid ceiling H307 thru H313 H370 thru H372 corridor H368 grid ceiling HL01 thru HL24 HL33 HL34 Phone #: ###-#### Inspection requested via web by Fabian Luna Corridor 368 soffit cans also did 260 and 268 corrdor hard lid rough in ok cover as requested
|
ELE15-02074
| Final | 7/30/2015 | 8/4/2015 | 8/4/2015 12:32:34 PM | A | FAIL |
|
|
Final inspection for this property please. Contact will be Justin Metcalf ###-####. Please call ahead of arrival as he will not be on site. Thank you so much and have a wonderful day! Phone #: ###-#### Inspection requested via web by Laura Longshaw Finished work from permit ELE15-00532. 210.8- GFCI shall be located in a readily accessible location. Island GFCI. 210.52(C)(5)- Kitchen counter top receptacle outlets shall not be located more than 20" above counter top. 210.52(C)(5)ex.- Island counter top receptacle outlet shall not be located more than 6" under over hang. 680.22(A)(2)2- Pool circulating pump shall have GFCI protection. 680.22(B)- Pool luminaire shall have GFCI protection. 680.26(B)(7)- Pool equipment shall be bonded with a #8 solid conductor. pump motor.
|
ELE15-02385
| Temporary Service | 8/4/2015 | 8/4/2015 | 8/4/2015 11:25:24 AM | P | CANC |
|
|
Rough-in inspection as well Phone #: ###-#### Inspection requested via web by Thaniel Bishop Needed permanent service inspection.
|
ELE15-02385
| Permanent Service | 8/4/2015 | 8/4/2015 | 8/4/2015 11:24:56 AM | P | PASS |
|
|
Rough-in inspection as well Phone #: ###-#### Inspection requested via web by Thaniel Bishop p/s o/h rec ok
|
ELE15-02392
| Final | 8/3/2015 | 8/4/2015 | 8/4/2015 10:59:12 AM | A | PASS |
|
|
Call Meco Myers for access ###-#### Phone #: ###-#### Inspection requested via web by jamie berg Final ok
|
ELE15-02392
| Electrical Rough-In | 8/4/2015 | 8/4/2015 | 8/4/2015 10:58:49 AM | P | PASS |
|
|
Call Meco Myers for access ###-#### Phone #: ###-#### Inspection requested via web by jamie berg Split system rough in ok cover
|
ELE15-02207
| Final | 8/3/2015 | 8/4/2015 | 8/4/2015 10:46:09 AM | A | PASS |
|
|
Shane is the contact his cell no. is ###-####. Phone #: ###-#### Inspection requested via web by Shawna Gates Final ok
|
ELE15-02405
| Final | 8/3/2015 | 8/4/2015 | 8/4/2015 10:36:00 AM | A | PASS |
|
|
Please call when done so I can fill in the trench Phone #: ###-#### Inspection requested via web by Thomas wilson Final ok
|
ELE15-02405
| Electrical Rough-In | 8/4/2015 | 8/4/2015 | 8/4/2015 10:35:40 AM | P | PASS |
|
|
Please call when done so I can fill in the trench Phone #: ###-#### Inspection requested via web by Thomas wilson Underground and detached garage rough in ok cover
|
ELE15-02387
| Temporary Service | 8/3/2015 | 8/4/2015 | 8/4/2015 10:22:04 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Richard Gratiot t/s u/g n ok
|
ELE15-01706
| Final | 8/3/2015 | 8/4/2015 | 8/4/2015 10:03:34 AM | A | PASS |
|
|
Homeowner there all day Phone #: ###-#### Inspection requested via web by Greg Idsinga Final ok
|
ELE15-01196
| Final | 8/3/2015 | 8/4/2015 | 8/4/2015 9:35:17 AM | A | FAIL |
|
|
Please contact James ###-#### with any questions. Phone #: ###-#### Inspection requested via web by Tracy Robertson 250.140- Frames of ranges and dryer shall connect to an equipment grounding conductor. Straps shall be removed.
|
ELE15-01545
| Final | 8/3/2015 | 8/4/2015 | 8/4/2015 9:33:58 AM | A | FAIL |
|
|
Please contact James ###-#### with any questions. Phone #: ###-#### Inspection requested via web by Tracy Robertson 250.140- Frames of ranges and dryers shall connect to an equipment grounding conductor. Straps shall be removed. AC shall be set or whip shall be removed.
|
ELE15-02404
| Electrical Rough-In | 8/3/2015 | 8/4/2015 | 8/4/2015 9:11:50 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn 210.52(B)(1)- Dining room receptacle outlets shall be wired with a 20 amp small appliance circuit.
|