Inspections for the day of: Tuesday, August 4, 2015.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-01367 ELE-Aging Inspection8/4/20158/4/20158/6/2015 7:40:05 AM CANC
too busy
ELE12-01653 ELE-Aging Inspection8/4/20158/4/20158/4/2015 3:39:28 PM DONE
Waiting for contractor to schedule
ELE15-02407 Rough-In Permanent Service8/3/20158/4/20158/4/2015 3:31:34 PMPPASS
turn north on Charlotte off of victory. take next left and then the next right is Kylee pl. Phone #: ###-#### Inspection requested via web by Brian Hughes Rough in ok cover p/s u/g n ok
ELE15-00262 Final8/4/20158/4/20158/4/2015 2:48:29 PMPPASS
Adam Wright Contact
Final Phone #: ###-#### Inspection requested via web by April Brown Final ok
ELE15-01203 Final8/4/20158/4/20158/4/2015 2:06:09 PMPPASS
Mike Phone #: ###-#### Corrections made. Final ok
ELE14-03151 Final8/4/20158/4/20158/4/2015 1:52:36 PMPNH
Adam Wright Contact
Final Phone #: ###-#### Inspection requested via web by April Brown Gates locked contact to schedule with city employee with key.
ELE14-01066 Electrical Rough-In8/4/20158/4/20158/4/2015 1:44:32 PMPPASS
hard lid ceiling H307 thru H313 H370 thru H372 corridor H368 grid ceiling HL01 thru HL24 HL33 HL34 Phone #: ###-#### Inspection requested via web by Fabian Luna Corridor 368 soffit cans also did 260 and 268 corrdor hard lid rough in ok cover as requested
ELE15-02074 Final7/30/20158/4/20158/4/2015 12:32:34 PMAFAIL
Final inspection for this property please. Contact will be Justin Metcalf ###-####. Please call ahead of arrival as he will not be on site. Thank you so much and have a wonderful day! Phone #: ###-#### Inspection requested via web by Laura Longshaw Finished work from permit ELE15-00532. 210.8- GFCI shall be located in a readily accessible location. Island GFCI. 210.52(C)(5)- Kitchen counter top receptacle outlets shall not be located more than 20" above counter top. 210.52(C)(5)ex.- Island counter top receptacle outlet shall not be located more than 6" under over hang. 680.22(A)(2)2- Pool circulating pump shall have GFCI protection. 680.22(B)- Pool luminaire shall have GFCI protection. 680.26(B)(7)- Pool equipment shall be bonded with a #8 solid conductor. pump motor.
ELE15-02385 Temporary Service8/4/20158/4/20158/4/2015 11:25:24 AMPCANC
Rough-in inspection as well
Phone #: ###-#### Inspection requested via web by Thaniel Bishop Needed permanent service inspection.
ELE15-02385 Permanent Service8/4/20158/4/20158/4/2015 11:24:56 AMPPASS
Rough-in inspection as well
Phone #: ###-#### Inspection requested via web by Thaniel Bishop p/s o/h rec ok
ELE15-02392 Final8/3/20158/4/20158/4/2015 10:59:12 AMAPASS
Call Meco Myers for access ###-#### Phone #: ###-#### Inspection requested via web by jamie berg Final ok
ELE15-02392 Electrical Rough-In8/4/20158/4/20158/4/2015 10:58:49 AMPPASS
Call Meco Myers for access ###-#### Phone #: ###-#### Inspection requested via web by jamie berg Split system rough in ok cover
ELE15-02207 Final8/3/20158/4/20158/4/2015 10:46:09 AMAPASS
Shane is the contact his cell no. is ###-####. Phone #: ###-#### Inspection requested via web by Shawna Gates Final ok
ELE15-02405 Final8/3/20158/4/20158/4/2015 10:36:00 AMAPASS
Please call when done so I can fill in the trench Phone #: ###-#### Inspection requested via web by Thomas wilson Final ok
ELE15-02405 Electrical Rough-In8/4/20158/4/20158/4/2015 10:35:40 AMPPASS
Please call when done so I can fill in the trench Phone #: ###-#### Inspection requested via web by Thomas wilson Underground and detached garage rough in ok cover
ELE15-02387 Temporary Service8/3/20158/4/20158/4/2015 10:22:04 AMAPASS
Phone #: ###-#### Inspection requested via web by Richard Gratiot t/s u/g n ok
ELE15-01706 Final8/3/20158/4/20158/4/2015 10:03:34 AMAPASS
Homeowner there all day Phone #: ###-#### Inspection requested via web by Greg Idsinga Final ok
ELE15-01196 Final8/3/20158/4/20158/4/2015 9:35:17 AMAFAIL
Please contact James ###-#### with any questions. Phone #: ###-#### Inspection requested via web by Tracy Robertson 250.140- Frames of ranges and dryer shall connect to an equipment grounding conductor. Straps shall be removed.
ELE15-01545 Final8/3/20158/4/20158/4/2015 9:33:58 AMAFAIL
Please contact James ###-#### with any questions. Phone #: ###-#### Inspection requested via web by Tracy Robertson 250.140- Frames of ranges and dryers shall connect to an equipment grounding conductor. Straps shall be removed.
AC shall be set or whip shall be removed.
ELE15-02404 Electrical Rough-In8/3/20158/4/20158/4/2015 9:11:50 AMAFAIL
Phone #: ###-#### Inspection requested via web by Darryn Coburn 210.52(B)(1)- Dining room receptacle outlets shall be wired with a 20 amp small appliance circuit.