ELE16-01732
| Final | 8/4/2016 | 8/4/2016 | 8/4/2016 3:18:20 PM | P | FAIL |
|
|
If you have any questions, please call Jared ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan 314.20 recessed boxes in combustable material shall have a listed extender(back west room) 406.6 faceplates missing (master bath&west back room) 406.6(d)(2) GFCI protection for non grounded outlets(west back room , can not locate the GFCI)
|
ELE15-02964
| Electrical Rough-In | 8/4/2016 | 8/4/2016 | 8/4/2016 2:56:14 PM | P | PASS |
|
|
call first, ###-#### Phone #: ###-#### Inspection requested via web by PAT MILLER upstairs only ok cover
|
ELE16-02161
| Permanent Service | 8/4/2016 | 8/4/2016 | 8/4/2016 2:36:35 PM | P | PASS |
|
|
If you have any questions, please call Jared ###-####. Thank you!! Phone #: ###-#### Inspection requested via web by Clay Morgan correction fixed, proper labels will be in place for final p/s o/h rec ok
|
ELE16-02160
| Permanent Service | 8/4/2016 | 8/4/2016 | 8/4/2016 2:35:54 PM | P | PASS |
|
|
If you have any questions, please call Jared ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan correction fixed, proper labels will be installed for final p/s o/h rec ok
|
ELE16-02159
| Permanent Service | 8/4/2016 | 8/4/2016 | 8/4/2016 2:35:10 PM | P | PASS |
|
|
If you have any questions, please call Jared ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan correction fixed, proper labels will be installed for final p/s o/h rec ok
|
ELE16-01823
| Permanent Service | 8/4/2016 | 8/4/2016 | 8/4/2016 2:34:10 PM | P | PASS |
|
|
If you have any questions, please call Jared ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan correction fixed final ok proper labels will be in place for final p/s o/h rec ok
|
ELE16-02522
| Final | 8/4/2016 | 8/4/2016 | 8/4/2016 1:54:57 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Randy Fletcher Final for dryer circuit and two branch circuits added in the basement ok
|
ELE15-02740
| Electrical Rough-In | 8/4/2016 | 8/4/2016 | 8/4/2016 1:40:11 PM | P | PASS |
|
|
Seth Phone #: ###-#### laundry/office/work area /server room suspended cielings only ok cover(u/f cable was still in place in front entry. Seth said he would make sure to havee it looked at) Discussed lobby area for a temp occ. No devices trimmed out and some missing lights.
|
ELE16-02283
| Rough-In Permanent Service | 8/4/2016 | 8/4/2016 | 8/4/2016 12:59:37 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Derek Newton need to check for bushings in meter and panel on final/ Rough-in ok cover p/s o/h rec ok
|
ELE15-01578
| Final | 8/4/2016 | 8/4/2016 | 8/4/2016 12:28:07 PM | P | PASS |
|
|
final for service ok
|
ELE16-02496
| Final | 8/4/2016 | 8/4/2016 | 8/4/2016 12:25:28 PM | P | PASS |
|
|
200 amp mobile service Phone #: ###-#### Inspection requested via web by jamie berg final for mobile home ok
|
ELE16-02528
| Final | 8/4/2016 | 8/4/2016 | 8/4/2016 11:17:00 AM | P | CANC |
|
|
Please call Dave ###-#### when you are on your way. If you have any questions, please call Jared ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan no final needed at this time
|
ELE16-02528
| Electrical Rough-In | 8/4/2016 | 8/4/2016 | 8/4/2016 11:16:30 AM | P | PASS |
|
|
Please call Dave ###-####, when you are on your way. If you have any questions, please call Jared ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan master closet only ok cover
|
ELE16-02479
| Electrical Rough-In | 8/3/2016 | 8/4/2016 | 8/4/2016 10:17:56 AM | A | PASS |
|
|
Cheryl Phone #: ###-#### out buildings ok cover
|
ELE16-01893
| Final | 8/3/2016 | 8/4/2016 | 8/4/2016 10:03:39 AM | A | PASS |
|
|
BOB ###-#### GARAGE CODE 4200 Phone #: ###-#### Inspection requested via web by Bob Glenn final ok
|
ELE16-02529
| Temporary Service | 8/3/2016 | 8/4/2016 | 8/4/2016 9:19:46 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn t/s u/g n ok
|
ELE16-01571
| Electrical Rough-In | 8/3/2016 | 8/4/2016 | 8/4/2016 9:19:09 AM | A | PASS |
|
|
Justin Hamby Phone #: ###-#### Inspection requested via web by Laurie Hoelscher verified disconnecting means and listing
|
ELE16-01571
| Final | 8/4/2016 | 8/4/2016 | 8/4/2016 9:18:50 AM | P | PASS |
|
|
Justin Hamby Phone #: ###-#### Inspection requested via web by Laurie Hoelscher final for AAA sign ok
|
ESC16-00303
| Site Final | 8/4/2016 | 8/4/2016 | 8/4/2016 9:16:01 AM | P | PASS |
|
|
site final ok
|
ESC16-00533
| Site Final | 8/4/2016 | 8/4/2016 | 8/4/2016 9:12:11 AM | P | PASS |
|
|
site final ok
|
ESC16-00205
| Site Final | 8/4/2016 | 8/4/2016 | 8/4/2016 9:06:39 AM | P | PASS |
|
|
site final ok
|
ELE16-02493
| Electrical Rough-In | 8/3/2016 | 8/4/2016 | 8/4/2016 8:46:39 AM | A | PASS |
|
|
walls, hard ceilings, ug Phone #: ###-#### Inspection requested via web by Lee VanSchoiack underground for drive thru menu boards, wall between eating area and playroom, dining area hard kids and bath hard lids ok cover
|
ELE16-02477
| Final | 8/4/2016 | 8/4/2016 | 8/4/2016 8:20:04 AM | P | CANC |
|
|
final inspection now that idaho power has been out to hook up Phone #: ###-#### >> Inspection requested via web by Randy Fletcher Inspection cancelled from web by: Randy Fletcher
|
ELE12-01934
| ELE-Aging Inspection | 8/4/2016 | 8/4/2016 | 8/4/2016 7:50:02 AM | | CANC |
|
|
too busy
|
ELE12-02132
| ELE-Aging Inspection | 8/4/2016 | 8/4/2016 | 8/4/2016 7:49:46 AM | | CANC |
|
|
too busy
|
ELE13-01961
| ELE-Aging Inspection | 8/4/2016 | 8/4/2016 | 8/4/2016 7:49:34 AM | | CANC |
|
|
too busy
|