Inspections for the day of: Tuesday, August 4, 2020.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-01970 Conference7/28/20208/4/20208/4/2020 3:37:51 PMPDONE
owner occupied building - screened // Julio Phone #: ###-#### Discussed option feeding ADU. ADU has a seperate address so a service is required. Individual performing work is a electrical contractor. informed if an electrical permit is pulled by elec contractor covering work done walls would not need opened. Marcello ###-####. If contractor not willing to permit work one side of all walls and ceiling will need opened up for inspection. Issues exist. 250.32- Seperate structures shall have grounding electrodes installed. 210.4- Ampacity for 14 ga. wire shall not exceed 15 amps. 30 amp installed. 422.30- A disconnecting means shall be installed for water heater when hooked up. Rest of list will be complete when energized.
ELE19-04799 Electrical Rough-In8/4/20208/4/20208/4/2020 2:12:17 PMPPASS
2 pole light bases on 5th floor amenity deck Phone #: ###-#### Inspection requested via web by Jason Parke Pole bases noted rough in ok cover.
ELE20-02419 Final8/4/20208/4/20208/4/2020 2:11:38 PMPPASS
Disconnect and conduit on ACHD traffic signal light pole at N.W. corner of Orchard and Irving St. Thanks! Phone #: ###-#### Inspection requested via web by Troy Hughes Final ok
ELE20-02419 Permanent Service8/4/20208/4/20208/4/2020 2:11:18 PMPPASS
Disconnect and conduit on ACHD traffic signal light pole at N.W. corner of Orchard and Irving St. Thanks! Phone #: ###-#### Inspection requested via web by Troy Hughes Grounding electrode of single ground rod verified thru photos, tested 1.81 ohms to ground. p/s u/g n ok
ELE20-02393 Final8/3/20208/4/20208/4/2020 11:07:27 AMAPASS
The contact is John Busnardo (electrician. Phone #: ###-#### Inspection requested via web by A.M.E. Office Final ok
ELE20-02636 Rough-In Permanent Service8/3/20208/4/20208/4/2020 10:14:30 AMAPASS
Phone #: ###-#### Inspection requested via web by Rodney Monroe Rough in ok cover p/s u/g n ok
ELE20-02363 Final8/3/20208/4/20208/4/2020 9:25:40 AMAPASS
Phone #: ###-#### Inspection requested via web by Steve Craig Final ok
ELE18-02642 Final7/31/20208/4/20208/4/2020 9:14:31 AMACANC
Please call 30 mins prior as Bob is not on site Phone #: ###-#### Inspection requested via web by Kerri Hamilton Called contact who informed me they need to reschedule due to some items were not completed.