BLD19-04518
| BLD-Ceiling Grid Inspection | 8/4/2020 | 8/4/2020 | 8/4/2020 4:10:48 PM | P | PASS |
|
|
Requesting a ceiling grid inspection in the vestibule, lobby and room 106. Please contact Markus Schlegel if you have any questions. Thank you. Phone #: ###-#### Inspection requested via web by Markus Schlegel
|
BLD20-00308
| BLD-Final | 8/3/2020 | 8/4/2020 | 8/4/2020 3:12:27 PM | A | NR |
|
|
Kyle */Screened*/ Phone #: ###-####
|
BLD20-00725
| BLD-Final | 8/3/2020 | 8/4/2020 | 8/4/2020 3:12:14 PM | A | NR |
|
|
Kyle */Screened*/ Phone #: ###-####
|
BLD20-00468
| BLD-Final | 8/4/2020 | 8/4/2020 | 8/4/2020 2:18:40 PM | P | PASS |
|
|
Plumbing issues address, requesting a permanent Certificate of Occupancy. Can be on Wednesday if no available times slots for Tuesday. Building opens at 10:00AM Phone #: ###-#### Inspection requested via web by Brady Hutchins. Plumbing issues have been resolved. Ok for perm occ.
|
BLD20-02525
| BLD-Final | 8/3/2020 | 8/4/2020 | 8/4/2020 2:15:32 PM | P | PASS |
|
|
Screened- Mike Phone #: ###-####. Ok for perm. occ.
|
BLD20-01770
| BLD-Footing | 8/3/2020 | 8/4/2020 | 8/4/2020 1:44:43 PM | P | PASS |
|
|
Ryan *screened* Phone #: ###-####
|
BLD20-00514
| BLD-Framing/Rough-in | 8/3/2020 | 8/4/2020 | 8/4/2020 11:51:44 AM | A | FAIL |
|
|
Phone #: 2088703262 >> Inspection requested via mobile web by Lucas Eells. Fireblock at ceiling level 1st. an d2nd. floors between staggered stud 2hr. wall. Provide putty pads on back to back electrical boxes. Provide letter from engineer deleting straps. Remove all foam from top plates and firecaulk, also firecaulk penetrations. C/N posted.
|
BLD20-00516
| BLD-Framing/Rough-in | 8/3/2020 | 8/4/2020 | 8/4/2020 11:48:45 AM | A | FAIL |
|
|
Phone #: 2088703262 >> Inspection requested via mobile web by Lucas Eells. No penetrations allowed in laydown parapets. Remove all plumbing from rated walls. Fireblock at ceiling level at 2hr. rated walls and firecaulk all penetrations. Remove all foam from top plates and firecaulk. Provide letter from engineer of record deleting straps. C/N posted.
|
BLD20-00517
| BLD-Framing/Rough-in | 8/3/2020 | 8/4/2020 | 8/4/2020 11:45:56 AM | A | FAIL |
|
|
Phone #: 2088703262 >> Inspection requested via mobile web by Lucas Eells. Remove all plumbing from 2hr. rated walls.fireblock fur downs in downstairs bathroom. No penetrations allowed in laydown parapet. C/N posted.
|
BLD20-01861
| BLD-Final | 8/3/2020 | 8/4/2020 | 8/4/2020 10:04:00 AM | A | PASS |
|
|
Screened- Ron Phone #: ###-####
|
BLD20-01861
| DOC - Permit Finaled | 8/4/2020 | 8/4/2020 | 8/4/2020 10:03:53 AM | P | PASS |
|
|
|
BLD20-02557
| BLD-Final | 8/3/2020 | 8/4/2020 | 8/4/2020 9:44:41 AM | A | DONE |
|
|
Inspection on a completed asphalt roofing project. Phone #: ###-#### Inspection requested via web by Michael La Pointe
|
BLD20-02557
| DOC - Permit Finaled | 8/4/2020 | 8/4/2020 | 8/4/2020 9:44:32 AM | P | PASS |
|
|
All work appeared to be done in accordance with local codes and ordinances.
|
BLD20-02550
| BLD-Other | 8/3/2020 | 8/4/2020 | 8/4/2020 9:34:00 AM | A | PASS |
|
|
Manufactured home block ; tie inspection Phone #: ###-#### Inspection requested via web by Ashleigh Meligan
|
BLD19-04421
| BLD-Footing | 8/3/2020 | 8/4/2020 | 8/4/2020 9:24:53 AM | A | FAIL |
|
|
Victor *screened* Phone #: ###-####. Needs to provide updated site plan approved by planning.
|
BLD20-01520
| BLD-Wall Bracing | 8/3/2020 | 8/4/2020 | 8/4/2020 8:43:32 AM | A | PASS |
|
|
Owen Phone #: ###-####
|