Inspections for the day of: Monday, August 5, 2002.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE02-02344 Temporary Service8/1/20028/5/20028/5/2002 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 08/01/2002 at 13:19:51. Contact: ###-####.

t/s u/g new ok 8/5/2002 11:10:00 AM
ELE02-01576 Final8/2/20028/5/20028/5/2002 12:00:00 AMAPASS
tim ###-#### ok 8/5/2002 10:51:38 AM
ELE02-02403 Final8/2/20028/5/20028/5/2002 12:00:00 AMAFAIL
CALL MARV ###-#### IF INSPECTION WILL NOT BE IN THE AM; Phone #: ###-####
cor. posted called $45.00 reinspection fee due 250.119(A) shall not ID #6 or smaller equip grd, 110,3(B) shall use manufactures means to bond p/s (bond screw) 8/5/2002 12:06:53 PM
ELE02-02442 Rough-In Permanent Service8/2/20028/5/20028/5/2002 12:00:00 AMPFAIL
###-#### mike or selena cor. posted met with owner 110.26 needs required clearence for service, 250 shall provide all required grounding and bonding for service, 230.24 clearence above roof with less than 4in12 pitch 230.72 all service disconnects shall be grouped inside or outside no violations to be retained a/c wiring, dryer, washer, subpanel, and owner to do work,not friend or general ? 8/5/2002 5:47:46 PM
ELE02-02429 Final8/2/20028/5/20028/5/2002 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 08/02/2002 at 16:56:47. Contact: ###-####. ok owner will remove low voltage attached to conduit elect. contractor installed 8/5/2002 6:22:58 PM
ELE02-02228 Rough-In Permanent Service8/5/20028/5/20028/5/2002 12:00:00 AMPPART
loren ###-#### walls ok 8/5/2002 4:17:51 PM
ELE02-02371 Electrical Rough-In8/5/20028/5/20028/5/2002 12:00:00 AMPPASS
mitch ###-#### u/g and green house ok 8/5/2002 3:50:59 PM
ELE02-02034 Rough-In Permanent Service8/5/20028/5/20028/5/2002 12:00:00 AMPFAIL
###-#### steve cor. posted called 300.4 nail plates and 11/4 inches 110.3(B) need papers from square D if 2 pole breaker can be use as single pole , remove foam from ceiling boxes 8/5/2002 3:34:31 PM
ELE02-01950 Final8/5/20028/5/20028/5/2002 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 08/05/2002 at 10:29:16. Contact: ###-####. ok 8/5/2002 5:48:38 PM