Inspections for the day of: Tuesday, August 5, 2008.
Number of inspections: 23
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-02135 Permanent Service8/5/20088/5/20088/5/2008 3:47:55 PMPPASS
Originally inspected as temp service and should have been Perm service
p/s u/g new ok
ELE08-02135 Final8/5/20088/5/20088/5/2008 3:47:29 PMPPASS
Originally inspected as temp service and should have been Perm service
ELE08-01616 Final8/4/20088/5/20088/5/2008 3:39:36 PMPPART
Final For Childrens Store Phone #: ###-#### Internet Inspection Request from: Jenni partail only needs show window recepts
ELE08-01615 Electrical Rough-In8/4/20088/5/20088/5/2008 3:38:45 PMPPART
rough-in for snake river pool & spa Phone #: ###-#### Internet Inspection Request from: Jenni Keller walls storage area ok
ELE08-01313 Final8/5/20088/5/20088/5/2008 2:57:36 PMPFAIL
Changed upstairs area to a wet bar. Removed 240 volt circuit from panel and upstairs. Check with Perry at the city office if necessary. Phone #: ###-#### Internet Inspection Request from: Rick Beckman
note still need plans to match also need wet bar installed called let contr know again what ever they want to do I have to have approved plans tthat match what is done
ESC08-00435 General Inspection8/5/20088/5/20088/5/2008 2:37:11 PMPPART
ok
ELE08-02168 Electrical Rough-In8/5/20088/5/20088/5/2008 2:28:53 PMPPART
request trench inspection as early as possible, thank you Phone #: ###-#### Internet Inspection Request from: gary batten ok
ESC08-00231 General Inspection8/5/20088/5/20088/5/2008 1:31:54 PMPPART
ok
ELE08-02174 Rough-In Permanent Service8/5/20088/5/20088/5/2008 1:30:31 PMPFAIL
Tom Phone #: ###-#### corr, called box fill switch bed rm outlet spacing M bed rm
300.4 nail plates and 11/4", 314.43 nails in outside boxes, 334.30 staples cables 8" of boxes, 300.14 short grd wires at boxes, 334.23 protect cables within 6ft of attic accesses
ELE08-02172 Electrical Rough-In8/5/20088/5/20088/5/2008 1:24:46 PMPFAIL
Please call when on way out, Lyubov ###-####//already started work w/out conference too many violations too note also stop work on job needs permits for MEC, BLD, plumbing
ELE08-01820 Final8/4/20088/5/20088/5/2008 10:42:24 AMAFAIL
Internet Inspection Request from: Jari Rivers corr 352.10(F) shall use schedule 80 all exposed RNC, 250.119 shall not ID #6 equip grd shall be green, 110.14(A) equip grd bus loose, 680.22(A)(3) needs gfci recept 10 ft 20 ft for spa
ELE08-01544 Final8/4/20088/5/20088/5/2008 10:39:03 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Jari Rivers corr called see per.# 1820 for details
ELE08-01883 Final8/4/20088/5/20088/5/2008 9:47:03 AMAPASS
Alan Phone #: ###-####
ELE08-01884 Final8/4/20088/5/20088/5/2008 9:46:50 AMAPASS
Alan Phone #: ###-####
ELE08-01886 Final8/4/20088/5/20088/5/2008 9:46:39 AMAPASS
Alan Phone #: ###-####
ELE08-01887 Final8/4/20088/5/20088/5/2008 9:46:27 AMAPASS
Alan Phone #: ###-#### ok
ELE08-01885 Final8/4/20088/5/20088/5/2008 9:46:09 AMAPASS
Alan Phone #: ###-#### ok
ELE08-02158 Electrical Rough-In8/4/20088/5/20088/5/2008 8:42:27 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Brandon Blackham ok
ELE08-02158 Final8/5/20088/5/20088/5/2008 8:42:13 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Brandon Blackham
ELE08-02158 Conference8/4/20088/5/20088/5/2008 8:41:41 AMADONE
brandon Note: relocate outlets Phone #: ###-####
ELE08-00711 ELE-Aging Inspection8/5/20088/5/20088/5/2008 7:37:49 AM PART
wsuc
ELE08-00528 ELE-Aging Inspection8/5/20088/5/20088/5/2008 7:37:23 AM PART
wsuc
ELE08-00778 ELE-Aging Inspection8/5/20088/5/20088/5/2008 7:36:58 AM PART
wsuc