ELE08-02135
| Permanent Service | 8/5/2008 | 8/5/2008 | 8/5/2008 3:47:55 PM | P | PASS |
|
|
Originally inspected as temp service and should have been Perm service p/s u/g new ok
|
ELE08-02135
| Final | 8/5/2008 | 8/5/2008 | 8/5/2008 3:47:29 PM | P | PASS |
|
|
Originally inspected as temp service and should have been Perm service
|
ELE08-01616
| Final | 8/4/2008 | 8/5/2008 | 8/5/2008 3:39:36 PM | P | PART |
|
|
Final For Childrens Store Phone #: ###-#### Internet Inspection Request from: Jenni partail only needs show window recepts
|
ELE08-01615
| Electrical Rough-In | 8/4/2008 | 8/5/2008 | 8/5/2008 3:38:45 PM | P | PART |
|
|
rough-in for snake river pool & spa Phone #: ###-#### Internet Inspection Request from: Jenni Keller walls storage area ok
|
ELE08-01313
| Final | 8/5/2008 | 8/5/2008 | 8/5/2008 2:57:36 PM | P | FAIL |
|
|
Changed upstairs area to a wet bar. Removed 240 volt circuit from panel and upstairs. Check with Perry at the city office if necessary. Phone #: ###-#### Internet Inspection Request from: Rick Beckman note still need plans to match also need wet bar installed called let contr know again what ever they want to do I have to have approved plans tthat match what is done
|
ESC08-00435
| General Inspection | 8/5/2008 | 8/5/2008 | 8/5/2008 2:37:11 PM | P | PART |
|
|
ok
|
ELE08-02168
| Electrical Rough-In | 8/5/2008 | 8/5/2008 | 8/5/2008 2:28:53 PM | P | PART |
|
|
request trench inspection as early as possible, thank you Phone #: ###-#### Internet Inspection Request from: gary batten ok
|
ESC08-00231
| General Inspection | 8/5/2008 | 8/5/2008 | 8/5/2008 1:31:54 PM | P | PART |
|
|
ok
|
ELE08-02174
| Rough-In Permanent Service | 8/5/2008 | 8/5/2008 | 8/5/2008 1:30:31 PM | P | FAIL |
|
|
Tom Phone #: ###-#### corr, called box fill switch bed rm outlet spacing M bed rm 300.4 nail plates and 11/4", 314.43 nails in outside boxes, 334.30 staples cables 8" of boxes, 300.14 short grd wires at boxes, 334.23 protect cables within 6ft of attic accesses
|
ELE08-02172
| Electrical Rough-In | 8/5/2008 | 8/5/2008 | 8/5/2008 1:24:46 PM | P | FAIL |
|
|
Please call when on way out, Lyubov ###-####//already started work w/out conference too many violations too note also stop work on job needs permits for MEC, BLD, plumbing
|
ELE08-01820
| Final | 8/4/2008 | 8/5/2008 | 8/5/2008 10:42:24 AM | A | FAIL |
|
|
Internet Inspection Request from: Jari Rivers corr 352.10(F) shall use schedule 80 all exposed RNC, 250.119 shall not ID #6 equip grd shall be green, 110.14(A) equip grd bus loose, 680.22(A)(3) needs gfci recept 10 ft 20 ft for spa
|
ELE08-01544
| Final | 8/4/2008 | 8/5/2008 | 8/5/2008 10:39:03 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Jari Rivers corr called see per.# 1820 for details
|
ELE08-01883
| Final | 8/4/2008 | 8/5/2008 | 8/5/2008 9:47:03 AM | A | PASS |
|
|
Alan Phone #: ###-####
|
ELE08-01884
| Final | 8/4/2008 | 8/5/2008 | 8/5/2008 9:46:50 AM | A | PASS |
|
|
Alan Phone #: ###-####
|
ELE08-01886
| Final | 8/4/2008 | 8/5/2008 | 8/5/2008 9:46:39 AM | A | PASS |
|
|
Alan Phone #: ###-####
|
ELE08-01887
| Final | 8/4/2008 | 8/5/2008 | 8/5/2008 9:46:27 AM | A | PASS |
|
|
Alan Phone #: ###-#### ok
|
ELE08-01885
| Final | 8/4/2008 | 8/5/2008 | 8/5/2008 9:46:09 AM | A | PASS |
|
|
Alan Phone #: ###-#### ok
|
ELE08-02158
| Electrical Rough-In | 8/4/2008 | 8/5/2008 | 8/5/2008 8:42:27 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Brandon Blackham ok
|
ELE08-02158
| Final | 8/5/2008 | 8/5/2008 | 8/5/2008 8:42:13 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Brandon Blackham
|
ELE08-02158
| Conference | 8/4/2008 | 8/5/2008 | 8/5/2008 8:41:41 AM | A | DONE |
|
|
brandon Note: relocate outlets Phone #: ###-####
|
ELE08-00711
| ELE-Aging Inspection | 8/5/2008 | 8/5/2008 | 8/5/2008 7:37:49 AM | | PART |
|
|
wsuc
|
ELE08-00528
| ELE-Aging Inspection | 8/5/2008 | 8/5/2008 | 8/5/2008 7:37:23 AM | | PART |
|
|
wsuc
|
ELE08-00778
| ELE-Aging Inspection | 8/5/2008 | 8/5/2008 | 8/5/2008 7:36:58 AM | | PART |
|
|
wsuc
|