ELE09-00773
| ELE-Aging Inspection | 8/5/2009 | 8/5/2009 | 8/11/2009 4:42:15 PM | | DONE |
|
|
no activity, suc
|
ELE09-00694
| Final | 8/5/2009 | 8/5/2009 | 8/5/2009 4:09:33 PM | P | PART |
|
|
This inspection will be for a final please. Contact is Rey. Thank you and have a great day! Phone #: ###-#### Internet Inspection Request from: Laura Longshaw working on corrections, need to change wiring at north light poles for green or bare grounds, repair connections- to be tight, add bell ends to u/g conduit in electrical rooms, strap emt, finish signs at panels for voltage identification, will schedule inspection for ammonia area later, told contractor owner can move in, have not signed t/o card yet, no esc this project,
|
ELE08-03233
| Final | 8/5/2009 | 8/5/2009 | 8/5/2009 4:07:15 PM | P | PART |
|
|
This inspection will be a reinspection for TCO. Contact is Rey. Thank you and have a great day! Phone #: ###-#### Internet Inspection Request from: Laura Longshaw still working on list of items, need to schedule inspection for ammonia area, told contractor owner can move things in, did not sign t/o card yet
|
ELE09-00829
| Electrical Rough-In | 8/5/2009 | 8/5/2009 | 8/5/2009 3:33:45 PM | P | PASS |
|
|
This inspection is for a in-wall rough-in. Contact is Rey. Thank you and have a great day! Phone #: ###-#### Internet Inspection Request from: Laura Longshaw office area walls only ok to cover, no esc this project
|
ELE09-00694
| Final | 8/5/2009 | 8/5/2009 | 8/5/2009 11:27:04 AM | A | PART |
|
|
look at dry goods for part final walked job with 412 and contractor, needs to add box support at outside fire valve,check listing for a/c in fire riser room, re-fuse disc for a/c, cover lb, bond piping system, in office, bond hw heater tighten all receptacles, strap mc, add fixture clip, add gfci by sink, ok to cover ceiling, add 8x8 box cover, fix dead receptacle, strap conduit, move bollards, provide work space about transformer disconnect, left correction notice NEC 110.26(A)(1),(2), (3) shall provide work space about electrical equipment- bollards and transformer disconnect
|
ELE09-01167
| Electrical Rough-In | 8/4/2009 | 8/5/2009 | 8/5/2009 8:18:36 AM | A | CANC |
|
|
stu - underground Phone #: ###-#### see conference
|
ELE09-01167
| Conference | 8/5/2009 | 8/5/2009 | 8/5/2009 8:09:43 AM | A | DONE |
|
|
stu - underground Phone #: ###-#### met contractor, reviewed inspection process, marking set of prints, crossings ok for u/g, told we need to see completed u/g conduit runs, watch depth and number of bends
|