Inspections for the day of: Wednesday, August 5, 2015.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE10-01304 ELE-Aging Inspection8/5/20158/5/20158/6/2015 7:41:01 AM CANC
too busy
ELE12-00179 ELE-Aging Inspection8/5/20158/5/20158/6/2015 7:40:45 AM CANC
too busy
ELE13-01474 ELE-Aging Inspection8/5/20158/5/20158/6/2015 7:40:29 AM CANC
too busy
ELE15-02437 Final8/5/20158/5/20158/5/2015 4:01:50 PMPPASS
convert existing 240v to 120v gas range. FINAL needed also. Phone #: ###-#### Inspection requested via web by Stuart Welton Final ok
ELE11-01094 Final8/4/20158/5/20158/5/2015 3:39:39 PMPCANC
Kevin Phone #: ###-#### Needed permanent service inspection
ELE11-01094 Permanent Service8/5/20158/5/20158/5/2015 3:39:32 PMPPASS
Kevin Phone #: ###-#### p/s u/g rec ok
ELE15-02361 Conference8/4/20158/5/20158/5/2015 3:01:32 PMPDONE
would like late as possible; Clif Phone #: ###-#### Discussed wiring associated with covered patio. GFCI protection, clearance for fans and outlets and fixtures from hot tub, bonding of metal parts with in 5' of hot tub "gutter"
ELE15-01288 Permanent Service8/5/20158/5/20158/5/2015 1:59:01 PMPFAIL
Phone #: ###-#### Inspection requested via web by Karl Paige 110.24- Available fault current shall be posted prior to permenant service. 230.2(E)- Breaker shall be identified as to their purpose.
ELE15-01287 Permanent Service8/5/20158/5/20158/5/2015 1:53:07 PMPFAIL
Phone #: ###-#### Inspection requested via web by Karl Paige 110.24- Available fault current shall be posted prior to permanent service. 230.2(E)- Breaker shall be identified as to their purpose.
ELE15-01289 Permanent Service8/5/20158/5/20158/5/2015 1:51:20 PMPFAIL
Phone #: ###-#### Inspection requested via web by Karl Paige 110.24- Available fault current and date calculated shall be posted on service prior to permenant service. 230.2(E)- Breaker shall be identified as to their purpose.
ELE15-01288 Electrical Rough-In8/5/20158/5/20158/5/2015 1:49:21 PMPPASS
wall cover Phone #: ###-#### Inspection requested via web by Karl Paige Wall rough in ok cover
ELE15-01604 Electrical Rough-In8/4/20158/5/20158/5/2015 1:25:54 PMPPASS
detached shop power and lighting.
Call General Contractor / John Binfet for access ###-#### Phone #: ###-#### Inspection requested via web by jamie berg Check on final ufer access. Rough in ok cover
ELE15-02428 Conference8/4/20158/5/20158/5/2015 10:48:16 AMADONE
Alan Phone #: ###-#### Discussed minimum size service to detached green house, only planning 2 circuits neede but want option for future so 60 amp needed. Depth of underground, number of bends between pull points, size of conductor for service, GFCI protection, tamper resistant receptacles and cover needed for wet location.
ELE15-02411 Electrical Rough-In8/5/20158/5/20158/5/2015 10:14:59 AMAPASS
lighting retrofit rough in Phone #: ###-#### Inspection requested via web by Tim Dunlop High bays changing to flourescent with motion sensor and 8' existing getting retro fit kits. UL listing confirmed. Rough in ok
ELE15-02429 Electrical Rough-In8/4/20158/5/20158/5/2015 9:52:09 AMAPASS
Underground: (1) pool light
Bonding: (4) Equipotential plane, (1) ladder, (1) handrail,
(1) pool light, (1) Steel/equipment Phone #: ###-#### Inspection requested via web by Lars Johnson Shell, light, 4 corners, rails bonded, and underground rough in ok cover
ELE15-01196 Final8/4/20158/5/20158/5/2015 9:17:54 AMAPASS
Phone #: ###-#### Inspection requested via web by Tracy Robertson Final ok
ELE15-01545 Final8/4/20158/5/20158/5/2015 9:17:21 AMAPASS
Phone #: ###-#### Inspection requested via web by Tracy Robertson Final ok
ELE15-02404 Rough-In Permanent Service8/4/20158/5/20158/5/2015 8:50:46 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn Rough in ok cover p/s u/g n ok
ELE15-02432 Permanent Service8/4/20158/5/20158/5/2015 7:43:51 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Jarod Murray Inspection cancelled from web by: Jarod Murray