ELE20-02532
| Final | 8/4/2020 | 8/5/2020 | 8/5/2020 2:37:34 PM | P | CANC |
|
|
Electrician: Chris ###-#### Homeowner: Nick ###-#### Phone #: ###-#### Inspection requested via web by Same Electric Asked contractor to reschedule due to covid restrictions. Occupied house.
|
ELE20-02716
| Rough-In Permanent Service | 8/5/2020 | 8/5/2020 | 8/5/2020 2:22:00 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Andrea Creek 250.24(A)(5)- On load side of service disconnecting means the grounded conductors shall not be connected to non-current carrying metal parts. Sub panel all equipment grounding conductors shall terminate in a ground bar seperate from the grounded conductors. Remove main bond screw. 408.41- In the panel board all grounded conductors shall terminate in an individual termimal that is not also use for another conductor.
|
ELE20-02716
| Electrical Rough-In | 8/5/2020 | 8/5/2020 | 8/5/2020 2:18:29 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Andrea Creek House rough in ok cover.
|
ELE20-02637
| Rough-In Permanent Service | 8/4/2020 | 8/5/2020 | 8/5/2020 11:45:38 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rodney Monroe Rough in ok cover p/s u/g n ok
|
ELE20-02638
| Rough-In Permanent Service | 8/4/2020 | 8/5/2020 | 8/5/2020 11:44:55 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rodney Monroe Rough in ok cover p/s u/g n ok
|
ELE20-02760
| Electrical Rough-In | 8/4/2020 | 8/5/2020 | 8/5/2020 10:41:25 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Don Conley Existing knob and tube to be confirmed abandoned by contractor. Enter between house and garage around back down exterior stairs to basement door. ADU rough in ok cover
|
ELE19-03829
| Electrical Rough-In | 8/4/2020 | 8/5/2020 | 8/5/2020 9:25:23 AM | A | CANC |
|
|
3rd floor ceiling in the restrooms Contact electrician onsite Shawn Evins. Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek Wanted request for Thursday, will recall when ready.
|
ELE19-00601
| Electrical Rough-In | 8/4/2020 | 8/5/2020 | 8/5/2020 9:14:36 AM | A | PASS |
|
|
4th floor corridor cover and UG for pool. Tyson is the contact. Phone #: ###-#### Inspection requested via web by Buster Bowen Level 4 corridor grid and pool wall lights underground rough in ok cover.
|
ELE20-02757
| Electrical Rough-In | 8/4/2020 | 8/5/2020 | 8/5/2020 8:52:23 AM | A | PASS |
|
|
Uffer inspection Contact electrician onsite Chris Gardner Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek City approved set of prints on site. Concrete encased electrode rough in ok cover
|