BLD19-01303
| BLD-Aging Inspection | 8/5/2020 | 8/5/2020 | 8/6/2020 9:35:48 AM | | PEND |
|
|
no final inspections requested//
|
BLD19-04669
| BLD-Final | 8/5/2020 | 8/5/2020 | 8/6/2020 7:09:08 AM | P | NR |
|
|
Vince -*/Screened*/ Phone #: ###-####
|
BLD20-01397
| BLD-Final | 8/5/2020 | 8/5/2020 | 8/5/2020 3:45:46 PM | P | PASS |
|
|
Call 15 minutes.... ok with video/photo // Gabe Phone #: ###-####
|
BLD20-01397
| DOC - Permit Finaled | 8/5/2020 | 8/5/2020 | 8/5/2020 3:45:37 PM | P | PASS |
|
|
|
BLD20-02250
| BLD-Footing | 8/4/2020 | 8/5/2020 | 8/5/2020 3:18:05 PM | P | NR |
|
|
Requesting early afternoon inspection. Concrete will be poured on site at 1:30pm Phone #: ###-#### Inspection requested via web by Preston Reynolds//need to provide easment information for irrigation company//plate dimensions are vague, and building may be encroaching on setback//advised to get approval form irrigation company in writing//if concrete is poured and posts set for building it is at the builders own risk//
|
BLD20-02265
| BLD-Footing | 8/5/2020 | 8/5/2020 | 8/5/2020 1:57:56 PM | P | PASS |
|
|
Footing inspection can be done in the PM today, if possible. Thanks. Phone #: ###-#### Inspection requested via web by rich prasch//setbacks will maintain existing//
|
BLD20-00344
| BLD-Ceiling Grid Inspection | 8/4/2020 | 8/5/2020 | 8/5/2020 1:40:14 PM | P | PART |
|
|
Miles- */Screened*/ Phone #: ###-####//grids phase 2 ok pending mechanical rough in//do not cover until mechanical has passed//
|
BLD20-01694
| BLD-Footing | 8/4/2020 | 8/5/2020 | 8/5/2020 12:25:29 PM | P | PART |
|
|
lunchtime inspection for 1pm concrete pour Phone #: ###-#### Inspection requested via web by Jennifer Anderson//WIP//need to maintain 13' 4" setbacks from building--will be measured at final--north east most carport will need to be exact at final//footing depths ok when loose material is removed//per plans//
|
BLD19-04799
| BLD-Framing/Rough-in | 8/5/2020 | 8/5/2020 | 8/5/2020 11:29:10 AM | A | PART |
|
|
truss Phone #: ###-#### Inspection requested via web by Shane Shade//see shane for truss bracing corrections and hager nailing//
|
BLD19-04797
| BLD-Framing/Rough-in | 8/5/2020 | 8/5/2020 | 8/5/2020 11:29:10 AM | A | PART |
|
|
Truss Phone #: ###-#### Inspection requested via web by Shane Shade//see shane for truss bracing corrections and hager nailing//
|
BLD19-04798
| BLD-Framing/Rough-in | 8/5/2020 | 8/5/2020 | 8/5/2020 11:29:09 AM | A | PART |
|
|
truss Phone #: ###-#### Inspection requested via web by Shane Shade////see shane for truss bracing corrections and hager nailing//
|
BLD19-04792
| BLD-Framing/Rough-in | 8/5/2020 | 8/5/2020 | 8/5/2020 11:29:09 AM | A | PART |
|
|
Truss Phone #: ###-#### Inspection requested via web by Shane Shade//see shane for truss bracing corrections and hager nailing//
|
BLD20-00089
| BLD-Foundation | 8/4/2020 | 8/5/2020 | 8/5/2020 9:59:25 AM | A | PART |
|
|
Stem Wall ispection. Tell, we have mud at 10:30, I will push it back if you can make it but please try to come before then. Thank you. Phone #: ###-#### Inspection requested via web by Shawn Plimmer//rebar ok per plans//vents will need vent wells due to elevations//contractor will submit updated site plan, changes due to meet rear setbacks//WIP//
|
BLD20-01972
| BLD-Foundation | 8/4/2020 | 8/5/2020 | 8/5/2020 9:35:43 AM | A | FAIL |
|
|
screened // Jeff Phone #: ###-####//footings poured without inspection//wall appears to meet plans//rear setbacks appear to only be 14' 8" from property line--asked contractor to run an offset line parallel to property line to get an acurate measurement//will need to meet 15' rear setback//
|
BLD20-02185
| BLD-Wall cover | 8/4/2020 | 8/5/2020 | 8/5/2020 9:33:45 AM | A | PASS |
|
|
screened // Justin Phone #: ###-####//per the contractor--plumbing will be completed when cabinets are installed//other trades have passed//will need code compliant smoke and smoke/co combos installed for final//other areas ok//
|
BLD20-01698
| BLD-Foundation | 8/4/2020 | 8/5/2020 | 8/5/2020 9:10:12 AM | A | PASS |
|
|
screened // Jeff Phone #: ###-####//setbacks ok measured off set survey pins on corners of property//wall ok per plans when hold downs added//
|
BLD19-03516
| BLD-Aging Inspection | 8/5/2020 | 8/5/2020 | 8/5/2020 8:27:44 AM | | PEND |
|
|
no inspections requested//
|