Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-02203 Final8/5/20158/6/20158/7/2015 8:51:17 AMPPASS
Roger Phone #: ###-#### final ok
ELE15-02452 Final8/6/20158/6/20158/7/2015 8:38:50 AMPPASS
temp power pole inspection Phone #: ###-#### Inspection requested via web by Andrea Creek t/s u/g n ok
ELE15-02433 Electrical Rough-In8/5/20158/6/20158/6/2015 5:13:29 PMPPASS
Part 2 of ceiling cover in dining. Von is the on site contact Phone #: ###-#### Inspection requested via web by Buster Bowen r/i t bar ceiling dining rm 100% ok to cover
ELE15-02352 Temporary Service8/6/20158/6/20158/6/2015 4:24:22 PMPPASS
Richard Phone #: ###-#### t/s o/h n ok
ELE15-02132 Electrical Rough-In8/6/20158/6/20158/6/2015 4:11:25 PMPNR
4th floor corridor grid ceiling inspection. Phone #: ###-#### Inspection requested via web by Rafael Castillo not ready
ELE14-01963 Electrical Rough-In8/6/20158/6/20158/6/2015 4:07:38 PMPPASS
Parking garage grid ceiling inspection west. Phone #: ###-#### Inspection requested via web by Rafael Castillo partial r/i west side t bar ceiling see e sheets
ELE15-02410 Rough-In Permanent Service8/6/20158/6/20158/6/2015 3:44:07 PMPPASS
IPCO on 3-4 day wait time. Dig line on Friday. Phone #: ###-#### Inspection requested via web by Cindie Swaim r/i ok p/s o/h rec ok NOTES: Must maintain 18 foot to service drop conductors, will look for fault current amount at final, will look for second ground rod at final. Additional work not associated with service will need separate permit.
ELE15-02447 Electrical Rough-In8/5/20158/6/20158/6/2015 2:47:37 PMAPASS
Cover inspection for Exterior porches and soffit cans. Also homeowner talked to Rex about looking at possible panel locations Phone #: ###-#### Inspection requested via web by Lynn Cable r/i soffits ok to cover NOTE:clearance issues above and in front of desired loadcenter location in mechanical room as per 2014 NEC 110.26(A)(2) and (3) and 110.26(E)(1)(a)-no piping or ductwork shall be located in this zone(dedicated equipment space)
ELE14-03316 Conference8/5/20158/6/20158/6/2015 1:47:10 PMADONE
Contact Tom Hartung for quetion on motor controller disconnecting means. Phone #: ###-#### Inspection requested via web by Tom Betty OK to install sump pump motor controller disconnects and motor controllers at locations shown, all capable of being locked out at disconnect and controllers as per NEC 430.102 (B)(b) for sump pump motors not directly in sight of controllers and disconnects.All controllers and disconnects and sump pump motors shall be labeled.
ELE15-01348 Conference8/5/20158/6/20158/6/2015 1:36:13 PMADONE
Contact Tom Hartung for question on acceptable dry in classification for project. Phone #: ###-#### Inspection requested via web by Tom Betty discuss installing mc cable in annex building metal stud walls prior to exterior wall installation. 2014 NEC 330.10(11) In wet locations where a corrosion resistant jacket is provided over the metallic covering AND any of the following conditions are met (a)the metallic covering is impervious to moisture (b) a jacket resistant to moisture is provided under the metal covering (c)The insulated conductors under the metallic covering are listed for use in wet locations
ELE15-01348 Electrical Rough-In8/5/20158/6/20158/6/2015 1:17:56 PMAPASS
Contact Tom Hartung for level 4 area 2 rough in slab location Phone #: ###-#### Inspection requested via web by Tom Betty r/i slab on deck conduits and floor boxes ok
ELE15-02131 Electrical Rough-In8/6/20158/6/20158/6/2015 12:13:03 PMAPASS
4th floor corridor grid ceilings. Phone #: ###-#### Inspection requested via web by Rafael Castillo east wing ceilingsok to cover
ELE14-03336 Permanent Service8/5/20158/6/20158/6/2015 11:48:33 AMAPASS
Contact: Jeremy Thornock. Phone #: ###-#### Inspection requested via web by Deb Gooden p/s u/g n ok (public works pedestal)
ELE14-03336 Final8/6/20158/6/20158/6/2015 11:45:57 AMPPASS
Contact: Jeremy Thornock. Phone #: ###-#### Inspection requested via web by Deb Gooden final ok
ELE14-03333 Final8/6/20158/6/20158/6/2015 11:41:39 AMPCANC
Contact: Jeremy Thornock Phone #: ###-#### Inspection requested via web by Deb Gooden city to busy, Jeremy says ok he will re schedule for tommarow am insp
ELE14-03333 Permanent Service8/5/20158/6/20158/6/2015 11:37:34 AMAPASS
Contact: Jeremy Thornock Phone #: ###-#### Inspection requested via web by Deb Gooden p/s u/g n ok (public works pedestal)
ELE14-03333 Final8/6/20158/6/20158/6/2015 11:32:34 AMPPASS
Contact: Jeremy Thornock Phone #: ###-#### Inspection requested via web by Deb Gooden final ok
ELE14-03333 Final8/5/20158/6/20158/6/2015 11:26:08 AMAPART
Contact: Jeremy Thornock Phone #: ###-#### Inspection requested via web by Deb Gooden final ok rms. 422,423,425, 427 thru 434, 436,437 and 438. Tanning bed has UL listing ok
ELE15-02145 Final8/6/20158/6/20158/6/2015 9:54:13 AMPCANC
rough in for lighting retrofit Phone #: ###-#### Inspection requested via web by Tim Dunlop needed r/i
ELE15-02145 Electrical Rough-In8/6/20158/6/20158/6/2015 9:53:43 AMPPASS
rough in for lighting retrofit Phone #: ###-#### Inspection requested via web by Tim Dunlop r/i ok all ul listed products
ELE15-02433 Electrical Rough-In8/5/20158/6/20158/6/2015 9:34:11 AMAPASS
Ceiling cover in kitchen and part 1 of dining. Von is the on site contact Phone #: ###-#### Inspection requested via web by Buster Bowen r/i t bar ceiling ok in kitchen and east dining rm ok to cover
ELE15-01908 Final8/5/20158/6/20158/6/2015 8:57:19 AMAFAIL
Phone #: ###-#### Inspection requested via web by Mark M need ul listing for new Seimens x ray equipment
ELE15-01603 Electrical Rough-In8/5/20158/6/20158/6/2015 8:29:32 AMAPASS
Phone #: ###-#### Inspection requested via web by Mark M r/i ceiling grid ok to cover E.D. x ray room 1
ELE13-01503 ELE-Aging Inspection8/6/20158/6/20158/6/2015 7:08:47 AM DONE
too busy