Inspections for the day of: Thursday, August 6, 2015.
Number of inspections: 22
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Story
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-01654 ELE-Aging Inspection8/6/20158/6/20158/10/2015 10:58:28 AM CANC
too busy
ELE15-01125 Final8/6/20158/6/20158/6/2015 4:09:57 PMPPASS
Call for access code - Ron Phone #: ###-#### final ok
ELE15-02431 Rough-In Permanent Service8/4/20158/6/20158/6/2015 4:09:25 PMPCANC
will not be ready till afternoon----call ron ###-#### Phone #: ###-#### Inspection requested via web by ron spen cer rough-in ok cover p/s u/g n ok
MIS15-00196 ELE-Conference7/31/20158/6/20158/6/2015 3:14:57 PMPDONE
Meet at 2PM, Per Tony discussed finishing exterior of building and third floor cover. electrician will assume permits for exterior
ELE15-02011 Final8/5/20158/6/20158/6/2015 1:29:22 PMACANC
Phone #: ###-#### Inspection requested via web by Emmet Bushman could not get in due to hardwood floors had just been finished
ELE15-00511 Final8/6/20158/6/20158/6/2015 1:05:17 PMPFAIL
Please call Bill ahead for entry info. Phone #: ###-#### Inspection requested via web by Rhonda Yoast 210.8 all kitchen receptacles shall be GFCI protected. Counter top GFCI does not trip
ELE15-02450 Electrical Rough-In8/6/20158/6/20158/6/2015 12:31:16 PMPFAIL
Phase 1 ceiling cover inspection for new LED recessed cans in grid ceiling Phone #: ###-#### Inspection requested via web by Steve Craig incomplete work 4-s covers missing/ fixtures whips not attached to any fixtures
ELE15-02442 Final8/6/20158/6/20158/6/2015 12:11:02 PMPPASS
Contact is Carl Pettek Phone #: ###-#### Inspection requested via web by Scott Campbell final ok
ELE15-00822 Final8/6/20158/6/20158/6/2015 12:10:21 PMPPASS
Contact is Carl Pettek Phone #: ###-#### Inspection requested via web by Scott Campbell final ok
ELE15-00822 Permanent Service8/5/20158/6/20158/6/2015 12:09:34 PMAPASS
Carl Phone #: ###-#### already completed
ELE15-02442 Permanent Service8/6/20158/6/20158/6/2015 12:08:31 PMPPASS
Contact is Carl Pettek Phone #: ###-#### Inspection requested via web by Scott Campbell ps u/g rec ok
ELE15-02360 Electrical Rough-In8/6/20158/6/20158/6/2015 11:57:20 AMPPASS
Contact is Alan Krishnek Phone #: ###-#### Inspection requested via web by Scott Campbell walls ok cover
ELE15-02399 Electrical Rough-In8/6/20158/6/20158/6/2015 11:38:50 AMPPASS
Mike Phone #: ###-#### rough-in ok cover
ELE15-02079 Electrical Rough-In8/5/20158/6/20158/6/2015 10:54:21 AMAPASS
Please call for access. Thanks. ###-####* Phone #: ###-#### Inspection requested via web by Clay Morgan kitchen and basement rough-in ok cover
ELE15-01970 Final7/31/20158/6/20158/6/2015 10:33:19 AMAPASS
Someone will be there. Thanks Phone #: ###-#### Inspection requested via web by Clay Morgan final ok
ELE15-02304 Electrical Rough-In8/5/20158/6/20158/6/2015 10:33:15 AMAPASS
Phone #: ###-#### Inspection requested via web by Krista Ratterree rough-in ok cover
ELE15-01985 Electrical Rough-In8/6/20158/6/20158/6/2015 10:04:20 AMACANC
Phone #: ###-#### Inspection requested via web by Jim Williams addition rough-in ok cover
ELE15-02446 Temporary Service8/5/20158/6/20158/6/2015 9:39:39 AMAPASS
Inspect existing temp pole for new meter set Phone #: ###-#### Inspection requested via web by Emmet Bushman t/s o/h rec ok
ELE15-02403 Rough-In Permanent Service8/5/20158/6/20158/6/2015 9:38:50 AMAPASS
Phone #: ###-#### Inspection requested via web by Emmet Bushman rough-in ok cover p/s u/g n ok
ELE15-02365 Temporary Service8/6/20158/6/20158/6/2015 9:13:57 AMAPASS
Phone #: ###-#### Inspection requested via web by Greg Traudt t/s u/g n ok
ELE15-02436 Electrical Rough-In8/5/20158/6/20158/6/2015 8:48:33 AMAPASS
Phone #: ###-#### Inspection requested via web by Dan Surerus kitchen remodel ok cover
ELE14-03453 Final8/5/20158/6/20158/5/2015 1:32:10 PMAPASS
Mike Phone #: ###-#### final ok