Inspections for the day of: Thursday, August 6, 2020.
Number of inspections: 25
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-03282 Final8/4/20208/6/20208/6/2020 3:39:06 PMPPASS
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil co locking caps ok- virtual video onsite- 5lb flue pass
MEC20-01236 Rough-in8/5/20208/6/20208/6/2020 3:11:10 PMPPASS
please call Shawn prior to arrival for access.
thanks,
Phone #: ###-#### Inspection requested via web by Nicholas Paige- phase 2 all rooms flex registers and seal ok- ok for ceiling tiles all areas- call in final when ready
MEC20-03315 Final8/6/20208/6/20208/6/2020 2:28:04 PMPPASS
Gas package unit in backyard. Homeowner Jerri Adams ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- outdoor package unit co ok
MEC20-03065 Rough-in8/6/20208/6/20208/6/2020 1:58:16 PMPFAIL
Phone #: ###-#### Inspection requested via web by Oleg Chervak
1- firecaulk range duct thru floor and extend below framing in kitchen
2- seal all boots 3rd floor
3- access platform 24" wide and 30x30 in front of unit and unobstructed
4- 1st floor bath fan needs to be 3 feet from property line and relocated

left notice
MEC20-03066 Rough-in8/6/20208/6/20208/6/2020 1:56:06 PMPFAIL
Phone #: ###-#### Inspection requested via web by Oleg Chervak
1- seal all boots 3rd floor
2- access platform 24" wide and 30x30 in front of unit and unobstructed
3- firecaulk range duct thru floor and route below framing in kitchen
4- exhaust fan 1st floor needs to be 3' from property line needs relocated

left notice
MEC20-03064 Rough-in8/6/20208/6/20208/6/2020 1:54:08 PMPFAIL
Phone #: ###-#### Inspection requested via web by Oleg Chervak-
1- seal all boots 3rd floor
2- extend access platform in attice to all the way accross front of unit

left notice
MEC20-03064 Pressure Test8/6/20208/6/20208/6/2020 1:53:10 PMPPASS
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass tagged meter location
MEC20-03066 Pressure Test8/6/20208/6/20208/6/2020 1:52:51 PMPPASS
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass tagged meter location
MEC20-03065 Pressure Test8/6/20208/6/20208/6/2020 1:52:06 PMPPASS
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass tagged meter location
MEC20-03067 Rough-in8/6/20208/6/20208/6/2020 1:51:24 PMPPASS
Phone #: ###-#### Inspection requested via web by Oleg Chervak- R/I ok
MEC20-03067 Pressure Test8/6/20208/6/20208/6/2020 1:50:56 PMPPASS
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass tagged meter
MEC20-03322 Final8/5/20208/6/20208/6/2020 12:23:06 PMPCANC
Please contact Curtis Benton prior to arriving Phone #: ###-#### Inspection requested via web by Rick Borg- due to COVID 19 city of Boise has suspended inspections in occupied homes at this time and no date set to at this time- virtual video acceptable with contractor meeting with me onsite- talked with Kyle about this by phone said they will reschedule
MEC20-00302 Card not on site to sign8/6/20208/6/20208/6/2020 12:02:01 PMPPASS
no card onsite to sign
MEC20-00302 Final8/6/20208/6/20208/6/2020 12:01:18 PMPPASS
Final inspection Building 11 tower 3 - any questions contact Shawn @ ###-#### Phone #: ###-#### Inspection requested via web by Amanda Casper- Tower 3 all units ok
MEC20-02758 Final8/5/20208/6/20208/6/2020 11:19:55 AMAFAIL
ready for final. Emailing balance report to Brian scores. Phone #: ###-#### Inspection requested via web by Drew Tverdy- M0.0 hood equipment shows a 7 foot hood- need to install hood shown or revise drawings with hood installed and submit to city of Boise for review-
MEC20-01456 Rough-in8/6/20208/6/20208/6/2020 10:18:40 AMPPASS
ok with video/photo // Leslie Phone #: ###-####- R/i ok 2 bath fans and dryer duct- call in final when ready
MEC20-02832 Final8/4/20208/6/20208/6/2020 9:50:07 AMAFAIL
Call Maria in route to inspection -- ###-####--equipment in garage Phone #: ###-#### Inspection requested via web by Justin Osterhout- furnace a/c coil co ok- need locking caps on a/c service ports- send pic for reinspect
MEC20-03147 Rough-in8/5/20208/6/20208/6/2020 9:17:44 AMAPART
Linset inspection for cover Phone #: ###-#### Inspection requested via web by GREGORY ANDERSEN- pre rock 4th floor units 401 402 403 404 405 406 407 408 and 410 dryer in wall and linsets ok-
MEC20-02890 Rough-in8/5/20208/6/20208/6/2020 8:50:33 AMAPASS
Phone #: ###-#### Inspection requested via web by Konrad Swartz
MEC20-02894 Rough-in8/5/20208/6/20208/6/2020 8:50:23 AMAPASS
Phone #: ###-#### Inspection requested via web by Konrad Swartz
MEC20-02410 Final7/31/20208/6/20208/6/2020 8:40:05 AMAPASS
2468 Phone #: ###-#### Inspection requested via web by Randy Hart
MEC20-02411 Final7/31/20208/6/20208/6/2020 8:39:55 AMAPASS
2468 Phone #: ###-#### Inspection requested via web by Randy Hart
MEC20-03112 Rough-in8/4/20208/6/20208/6/2020 8:22:36 AMAPART
Please call Rich ###-#### Phone #: ###-#### Inspection requested via web by Beka Hereau- R/I on ducting and seal ok- ok for ceiling tiles- need to call in anoth R/I inspection when new fan coil installed- 1st floor exhaust will need to be inspected also
MEC19-04579 Mec-Aging Inspection8/6/20208/6/20208/6/2020 7:47:45 AM FAIL
contractor needs to schedule inspection if a/c has been set- extension granted on 5-7-20 to 11-7-20 permit will expire at this date or next aging if no activity
MIS20-00241 MEC-Conference8/3/20208/6/20208/5/2020 1:19:55 PMADONE
check for permit- permit pulled under 6708 Fairview