Inspections for the day of: Monday, August 7, 2017.
Number of inspections: 6
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC17-03317 Rough-in8/4/20178/7/20178/7/2017 10:25:18 AMAPASS
CLINT ###-#### Phone #: ###-#### Inspection requested via web by Jason Robinson
MEC17-02247 Final8/4/20178/7/20178/7/2017 10:23:41 AMAPASS
CLINT ###-#### Phone #: ###-#### Inspection requested via web by Jason Robinson
MEC17-03255 Rough-in8/4/20178/7/20178/7/2017 10:11:20 AMAFAIL
Phone #: ###-#### Inspection requested via web by Debbie Marino- outside air needs metal ducting insulated- dryer vent ovaled out in ceiling, needs to maintain 4" round- insulation shield on B vent needs 1" clearance and no gaps in shield 2nd floor fitting and pipe- need insulation shield on B vent in garage- lineset needs ran- B vent 2nd floor chase needs plumber strap secured- left correction notice front entry window
MEC17-03255 Pressure Test8/4/20178/7/20178/7/2017 9:59:59 AMAFAIL
Phone #: ###-#### Inspection requested via web by Debbie Marino- flue guage at zero- gas guage wont zero out
MEC17-03008 Final8/4/20178/7/20178/7/2017 9:12:50 AMAFAIL
Call Jamie 30 mins prior to arrival. she must be gone by noon. ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby- supply plenum needs sealed and insulated- R/A plenum needs insulated- b vent needs 1" clearance and trim ring installed- need to run weather tight whip from outdoor unit to disconnect not to metal box mounted on wall needs to be weather tight- need to provide CO detectors
MEC16-03145 Mec-Aging Inspection8/7/20178/7/20178/7/2017 8:43:20 AM CANC
no calls