Inspections for the day of: Friday, August 8, 2008.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD08-00630 BLD-Final8/8/20088/8/20088/8/2008 5:33:35 PMPNR
Michelle ###-####. No approved plans.
BLD06-02489 BLD-Final8/5/20088/8/20088/8/2008 3:05:28 PMPPART
mike Phone #: ###-####. ok for temp. occ. Will need plumbing and elec to go perm, provide letterfrom special insp. agency, have front counter installed and exterior landing in back.
ESC08-00113 Random Inspection8/8/20088/8/20088/8/2008 1:57:01 PMPPART
Neess to clean debri from const. site. Landscaper to start on Monday 8/11 as per contractor. Remainder of BMP's left in place due to empty lots still in sub.
BLD08-00310 BLD-Final8/7/20088/8/20088/8/2008 1:54:50 PMPPASS
spencer Phone #: ###-####
BLD08-00310 DOC - Permit Finaled8/8/20088/8/20088/8/2008 1:54:41 PMPPASS
Cert of occ. issued. Fine grading completed.
BLD08-00523 BLD-Framing/Rough-in8/7/20088/8/20088/8/2008 11:16:05 AMAPART
Terry Phone #: ###-####. Visually inspected nailing, blocking and straps for roof diaphragm over drive thru area only. ok to cover.
ESC08-00193 Random Inspection8/8/20088/8/20088/8/2008 11:12:45 AMAPASS
ESC permit sign posted at controlled enterance point. All BMP's ok. track out is being swept as needed.
ESC08-00234 Site Preparation8/8/20088/8/20088/8/2008 11:11:09 AMAPASS
ESC permit sighn posted, limited excavation work, all excavation is in interior portion of bldg. site was clean.
BLD08-00622 BLD-Foundation8/7/20088/8/20088/8/2008 11:09:59 AMAPART
Ian Phone #: ###-####wip. Special insp. to verify reinforcement for interior column pad footings, also will do epoxy insp.
BLD08-00391 BLD-Final8/8/20088/8/20088/8/2008 10:13:40 AMAPASS
BLD08-00523 DOC - Permit Finaled8/8/20088/8/20088/8/2008 10:12:36 AMPPASS
Demo has been completed.
BLD08-00620 BLD-Framing/Rough-in8/7/20088/8/20088/8/2008 9:23:45 AMAPASS
Eric- ceiling Phone #: ###-####. 2nd. layer 5/8 type x at floor ceiling assembly ok. 1hr. bearing wall ok. ok to cover.
ESC08-00279 Random Inspection8/8/20088/8/20088/8/2008 9:22:48 AMAPART
Needs to sweep sidewalk and driveway. Also needs to clean up construction debri from jobsite. c/n posted.
BLD08-01602 BLD-Other8/7/20088/8/20088/8/2008 9:08:38 AMAPASS
gay or robert - block and tie - please call 1/2 hr prior to inspection Phone #: ###-####
BLD08-01602 DOC - Permit Finaled8/8/20088/8/20088/8/2008 9:08:27 AMPPASS
block and tie ok. Skirting in place.
ESC08-00631 General Inspection8/8/20088/8/20088/8/2008 8:56:14 AMAPASS
ESC permit sign posted. Very limited excavation work, non exterior, all interior for plumbing. site clean. ok.
BLD08-01594 BLD-Framing/Rough-in8/7/20088/8/20088/8/2008 8:54:51 AMAPASS
grant Phone #: ###-#### Note:please call 1/2 hr prior to inspection. Interior wood framed walls.