Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-00850 ELE-Aging Inspection8/8/20148/8/20148/8/2014 1:45:44 PM DONE
Waiting for contractor to schedule
ELE14-02046 Electrical Rough-In8/7/20148/8/20148/8/2014 1:42:55 PMPPASS
need approval to cover walls. Phone #: ###-#### Inspection requested via web by Alan Lusk When job started with service change listed this address with unit A and B. Wall rough in unit B or 2774. Wall rough in ok cover
ELE14-02182 Temporary Service8/8/20148/8/20148/8/2014 1:15:23 PMPPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn t/s u/g n ok
ELE14-02017 Permanent Service8/7/20148/8/20148/8/2014 12:37:53 PMAPASS
Contact - Tod Phone #: ###-#### Inspection requested via web by Harvey Reyna p/s o/h rec ok
ELE14-02183 Permanent Service8/8/20148/8/20148/8/2014 12:04:34 PMPPASS
Barry ###-#### p/s o/h n ok
ELE14-01963 Temporary Service8/7/20148/8/20148/8/2014 11:18:48 AMAPASS
Temporary power pole next to McAlvain''s trailer. Phone #: ###-#### Inspection requested via web by Rafael Castillo Informed contractor of 6x6" minimum required by Idaho Power. 4x6" present short swing. t/s o/h n ok
ELE14-01963 Electrical Rough-In8/7/20148/8/20148/8/2014 11:14:52 AMAPASS
Rough in of boxes and conduit in shear wall in southwest part of building. Phone #: ###-#### Inspection requested via web by Rafael Castillo Under ground and mason boxes marked on contracor print rough in ok cover
ELE14-01978 Rough-In Permanent Service8/7/20148/8/20148/8/2014 10:18:14 AMAFAIL
Phone #: ###-#### Inspection requested via web by Seth Stears 250.53(D)(2)- When rod is used for grounding electrode system for permenant service supplemental rod required.
330.30- MC cable shall be supported at inervals not exceeding 6'
ELE14-01979 Rough-In Permanent Service8/7/20148/8/20148/8/2014 10:16:16 AMAFAIL
Phone #: ###-#### Inspection requested via web by Seth Stears 250.53(D)(2)- When rod is used as grounding electrode system for permenant service supplemental rod required.
330.30- MC cable shall be supported at intervals not exceeding 6'
ELE14-02181 Final8/8/20148/8/20148/8/2014 9:25:13 AMPPASS
Phone #: ###-#### Inspection requested via web by Kotton Corder Final ok
ELE14-02181 Permanent Service8/8/20148/8/20148/8/2014 9:24:21 AMPPASS
Phone #: ###-#### Inspection requested via web by Kotton Corder Replaced broken hub. p/s o/h rec ok
ELE14-01701 Final8/7/20148/8/20148/8/2014 9:14:59 AMAFAIL
Phone #: ###-#### Inspection requested via web by daniel bibikov All units kitchen bar devices shall have covers.
Fire alarm wire shall have box.
MIS14-00162 ELE-Conference7/25/20148/8/20147/25/2014 10:13:37 AMACANC
Reinspect unit for corrections compiance