Inspections for the day of: Thursday, August 9, 2007.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD07-01399 BLD-Footing8/9/20078/9/20078/9/2007 5:22:44 PMPCANC
Scheduled by a contractor via Hello! on 8/9/2007 at 8:16:10 AM. Contact: ###-####.
BLD07-01398 BLD-Footing8/9/20078/9/20078/9/2007 5:22:32 PMPCANC
Scheduled by a contractor via Hello! on 8/9/2007 at 8:17:36 AM. Contact: ###-####.
BLD07-01401 BLD-Footing8/9/20078/9/20078/9/2007 5:22:16 PMPCANC
Scheduled by a contractor via Hello! on 8/9/2007 at 8:13:07 AM. Contact: ###-####.
BLD07-01400 BLD-Footing8/9/20078/9/20078/9/2007 5:21:59 PMPCANC
Scheduled by a contractor via Hello! on 8/9/2007 at 8:14:36 AM. Contact: ###-####.
BLD07-01402 BLD-Footing8/9/20078/9/20078/9/2007 5:21:35 PMPCANC
Scheduled by a contractor via Hello! on 8/9/2007 at 8:11:34 AM. Contact: ###-####.
BLD07-01466 BLD-Other8/9/20078/9/20078/9/2007 4:06:38 PMPPART
matt Note: wall Phone #: ###-####. Interior walls for new tub and master bath. pend. elec.
BLD07-01812 BLD-Framing/Rough-in8/9/20078/9/20078/9/2007 3:48:41 PMPPASS
Scheduled by a contractor via Hello! on 8/9/2007 at 8:20:46 AM. ok to insul. Needs to add strongback to gable end and add straps.
BLD07-01509 BLD-Conference8/9/20078/9/20078/9/2007 2:53:16 PMPDONE
nancy - as soon as possible Phone #: ###-####. Noted to homeowner that a beam would be required to carry gable end truss. Also noted to homeowner to contact truss engineer for correct size applications.
BLD07-01237 BLD-Energy code compliance8/8/20078/9/20078/9/2007 2:24:20 PMPPASS
lee Phone #: ###-####
BLD07-00207 BLD-Final8/9/20078/9/20078/9/2007 2:12:30 PMPPASS
dave Phone #: ###-####
BLD07-00207 DOC - Permit Finaled8/9/20078/9/20078/9/2007 2:12:17 PMPPASS
Final ok. Noted all required signatures.
MIS07-00179 BLD-Conference8/9/20078/9/20078/9/2007 1:51:19 PMPDONE
This is for a home purchase. Please contact Realtor, Larry at least 1/2 hour before arriving so he may give you access.

Thanks! Phone #: ###-#### Internet Inspection Request from: Connie LaFrainer. Provide GFI in kitchen and bathrooms. Provide smoke detectors in all bedrooms.
BLD07-01819 BLD-Framing/Rough-in8/8/20078/9/20078/9/2007 12:15:00 PMAPART
sonny Phone #: ###-####. New interior stell stud wall for conditioned warehouse area. Still need to inspect new pass through. ok to insul.
BLD06-00057 BLD-Other8/8/20078/9/20078/9/2007 12:01:03 PMANR
scott - ceiling grid Phone #: ###-####. Approved plan calls for hardlid, contractor has switched to grid ceiling. Needs to resubmit refected ceiling plan for approval.
BLD07-01858 BLD-Final8/8/20078/9/20078/9/2007 11:28:07 AMAFAIL
John; Phone #: ###-#### Internet Inspection Request from: Darla Downs. Lot not cleaned, still trash and wood debris.
BLD07-01053 BLD-Other8/8/20078/9/20078/9/2007 11:14:01 AMACANC
Scheduled by a contractor via Hello! on 8/8/2007 at 2:22:26 PM. Contact: ###-####.
BLD07-01225 BLD-Framing/Rough-in8/8/20078/9/20078/9/2007 10:53:24 AMAPART
Scheduled by a contractor via Hello! on 8/8/2007 at 2:04:36 PM. Contact: ###-####. Exterior shear nailing and roof diaphragm. Also inspected framing. Needs to complete fireblocking. ok to insul.
BLD07-01226 BLD-Framing/Rough-in8/8/20078/9/20078/9/2007 10:08:51 AMACANC
Scheduled by a contractor via Hello! on 8/8/2007 at 1:50:00 PM. Contact: ###-####.