Inspections for the day of: Tuesday, August 9, 2016.
Number of inspections: 7
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE16-01838 Electrical Rough-In8/8/20168/9/20168/9/2016 3:02:30 PMPPASS
ceiling level 4 annex and walls on level 5 annex Phone #: ###-#### Inspection requested via web by Brandon Robinson
Areas as noted will check access 4th HVAC junction box walls and ceilings rough in ok cover
ELE16-00089 Electrical Rough-In8/9/20168/9/20168/9/2016 2:56:29 PMPPASS
R/I inspection of walls, different areas. Call Bob for inspection. Phone #: ###-#### Inspection requested via web by Rafael Castillo
Ballroom pocket walls, prefunction door walls, prefunction soffits and droplids as noted on prints rough in ok cover
ELE15-02740 Final8/8/20168/9/20168/9/2016 1:01:52 PMAFAIL
Seth Phone #: ###-####
110.3- Furniture with electrical installed as part of furniture shall be listed.
110.27(A)- Switches operating at 50 volts or more shall be guarded against accidental contact by approved enclosures. Light switches for lights mounted in furniture.
314.20- Boxes mounted in a combustible material shall be flush or have extension ring installed.
314.29- Boxes located behind furniture fixed in place shall be accessible. Behind TV panel.
400.9- Flexible cords shall be installed in continuous lengths without a splice or tap.
ELE16-02491 Final8/6/20168/9/20168/9/2016 11:42:46 AMAPASS
We are replacing an OH mast on an existing service and have the power co. sheduled to disconnect at 9 am. We are hoping to have it ready for inspection and reconnect around 11 am. Phone #: ###-#### Inspection requested via web by Jonathan Poot Final ok
ELE16-02491 Permanent Service8/9/20168/9/20168/9/2016 11:42:14 AMPPASS
We are replacing an OH mast on an existing service and have the power co. sheduled to disconnect at 9 am. We are hoping to have it ready for inspection and reconnect around 11 am. Phone #: ###-#### Inspection requested via web by Jonathan Poot
p/s o/h rec ok
ELE16-02576 Permanent Service8/8/20168/9/20168/9/2016 9:28:26 AMAPASS
Inspection requested via web by CHRIS CARMINE
BCC 4-05-32- Code violations not to be retained.
Electrical contractor stated house to be completely remodelled.
-Remove exposed live ends.
-Check for splices not in boxes.
-Remove MN cable on front for flood lights.
-Check overcurrent protection, 30 amp on 30 amp max circuits.
p/s o/h rec ok
ELE16-01799 Final8/8/20168/9/20168/8/2016 4:34:46 PMPCANC
Phone #: ###-#### >> Inspection requested via web by kendall bender Inspection cancelled from web by: kendall bender