ELE16-01838
| Electrical Rough-In | 8/8/2016 | 8/9/2016 | 8/9/2016 3:02:30 PM | P | PASS |
|
|
ceiling level 4 annex and walls on level 5 annex Phone #: ###-#### Inspection requested via web by Brandon Robinson Areas as noted will check access 4th HVAC junction box walls and ceilings rough in ok cover
|
ELE16-00089
| Electrical Rough-In | 8/9/2016 | 8/9/2016 | 8/9/2016 2:56:29 PM | P | PASS |
|
|
R/I inspection of walls, different areas. Call Bob for inspection. Phone #: ###-#### Inspection requested via web by Rafael Castillo Ballroom pocket walls, prefunction door walls, prefunction soffits and droplids as noted on prints rough in ok cover
|
ELE15-02740
| Final | 8/8/2016 | 8/9/2016 | 8/9/2016 1:01:52 PM | A | FAIL |
|
|
Seth Phone #: ###-#### 110.3- Furniture with electrical installed as part of furniture shall be listed. 110.27(A)- Switches operating at 50 volts or more shall be guarded against accidental contact by approved enclosures. Light switches for lights mounted in furniture. 314.20- Boxes mounted in a combustible material shall be flush or have extension ring installed. 314.29- Boxes located behind furniture fixed in place shall be accessible. Behind TV panel. 400.9- Flexible cords shall be installed in continuous lengths without a splice or tap.
|
ELE16-02491
| Final | 8/6/2016 | 8/9/2016 | 8/9/2016 11:42:46 AM | A | PASS |
|
|
We are replacing an OH mast on an existing service and have the power co. sheduled to disconnect at 9 am. We are hoping to have it ready for inspection and reconnect around 11 am. Phone #: ###-#### Inspection requested via web by Jonathan Poot Final ok
|
ELE16-02491
| Permanent Service | 8/9/2016 | 8/9/2016 | 8/9/2016 11:42:14 AM | P | PASS |
|
|
We are replacing an OH mast on an existing service and have the power co. sheduled to disconnect at 9 am. We are hoping to have it ready for inspection and reconnect around 11 am. Phone #: ###-#### Inspection requested via web by Jonathan Poot p/s o/h rec ok
|
ELE16-02576
| Permanent Service | 8/8/2016 | 8/9/2016 | 8/9/2016 9:28:26 AM | A | PASS |
|
|
Inspection requested via web by CHRIS CARMINE BCC 4-05-32- Code violations not to be retained. Electrical contractor stated house to be completely remodelled. -Remove exposed live ends. -Check for splices not in boxes. -Remove MN cable on front for flood lights. -Check overcurrent protection, 30 amp on 30 amp max circuits. p/s o/h rec ok
|
ELE16-01799
| Final | 8/8/2016 | 8/9/2016 | 8/8/2016 4:34:46 PM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by kendall bender Inspection cancelled from web by: kendall bender
|