ESC09-00445
| General Inspection | 9/10/2009 | 9/10/2009 | 9/10/2009 4:41:17 PM | P | PART |
|
|
see 380 comments
|
ESC09-00461
| General Inspection | 9/10/2009 | 9/10/2009 | 9/10/2009 4:40:23 PM | P | PASS |
|
|
looked ok
|
ELE09-01704
| Electrical Rough-In | 9/10/2009 | 9/10/2009 | 9/10/2009 3:34:49 PM | P | PASS |
|
|
neil Phone #: ###-#### called contractor, ric ok
|
ELE09-01704
| Permanent Service | 9/10/2009 | 9/10/2009 | 9/10/2009 3:29:37 PM | P | PASS |
|
|
neil Phone #: ###-#### called contractor, p/s u/g n ok
|
ELE09-01373
| Electrical Rough-In | 9/10/2009 | 9/10/2009 | 9/10/2009 3:25:07 PM | P | PASS |
|
|
this is for ceiling cover the data guy said everything is tyed up and plenum rated ready to go. thanks Phone #: ###-#### Internet Inspection Request from: Don Lustig corrections made, ok to cover ceiing only, no esc this project
|
ELE09-00946
| Final | 9/10/2009 | 9/10/2009 | 9/10/2009 3:13:28 PM | P | PART |
|
|
This will be for a final inspection. Contact is Rey. Thank you and have a great day! Phone #: ###-#### Internet Inspection Request from: Laura Longshaw truck wash areas not done, rest ok to final, done by 412 and 370, no esc this project
|
ELE09-00827
| Final | 9/10/2009 | 9/10/2009 | 9/10/2009 2:13:29 PM | P | PASS |
|
|
This will be for a final inspection. Contact is Rey. Thank you and have a great day! Phone #: ###-#### Internet Inspection Request from: Laura Longshaw ok to final, signed occupancy card, no esc this project, done by 412 and 370
|
ELE09-01343
| Rough-In Permanent Service | 9/9/2009 | 9/10/2009 | 9/10/2009 11:42:49 AM | A | CANC |
|
|
Rough in inspection needed for the basement only, any questions please call, thx, Terry. Phone #: ###-#### Internet Inspection Request from: Stephen Kren called, contractor asked to cancel
|
ELE09-01703
| Electrical Rough-In | 9/10/2009 | 9/10/2009 | 9/10/2009 11:05:35 AM | A | PASS |
|
|
call for access Phone #: ###-#### Internet Inspection Request from: PAT MILLER ric ok, no esc this project
|
ELE09-00829
| Final | 9/9/2009 | 9/10/2009 | 9/10/2009 10:12:16 AM | A | PASS |
|
|
This will be for a final inspection. Contact is Rey. Thank you and please have a great day. Phone #: ###-#### Internet Inspection Request from: Laura Longshaw 412 and 370 did inspection, ok to final, signed occupancy card, no esc this project
|
ELE09-01705
| Final | 9/10/2009 | 9/10/2009 | 9/10/2009 9:00:19 AM | P | CANC |
|
|
Please call 20 min prior to arrival. Phone #: ###-#### Internet Inspection Request from: John Edwards Inspection cancelled from web by: John Edwards
|
ELE09-01685
| Rough-In Permanent Service | 9/9/2009 | 9/10/2009 | 9/10/2009 8:31:57 AM | A | CANC |
|
|
Phone #: ###-#### Internet Inspection Request from: Stephen Kren see p/s and ri
|
ELE09-01685
| Permanent Service | 9/10/2009 | 9/10/2009 | 9/10/2009 8:31:34 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Stephen Kren p/s u/g n ok
|
ELE09-01685
| Electrical Rough-In | 9/10/2009 | 9/10/2009 | 9/10/2009 8:30:13 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Stephen Kren called, left correction notice, NEC 110.3(A)(B) and BCC 4-05-33(A)(B) shall use listed or labelled equipment- #14 nm cable, NEC 210.52(A)(1)(2) shall install receptacles such that no point is over 6' along wall line from an outlet and also in 2' walls
|