Inspections for the day of: Wednesday, September 10, 2014.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE14-02438 Electrical Rough-In9/10/20149/10/20149/11/2014 10:01:52 AMPPASS
Justin Phone #: ###-#### Sun room rough in ok cover
ELE12-01786 ELE-Aging Inspection9/10/20149/10/20149/10/2014 5:22:51 PM DONE
Waiting on owner
ELE14-01106 Final9/10/20149/10/20149/10/2014 4:34:26 PMPFAIL
Joe Phone #: ###-#### 430.109 Disconnecting means shall be installed on door openers and pressure washer
ELE14-00993 Electrical Rough-In9/10/20149/10/20149/10/2014 3:32:47 PMPCANC
Phone #: ###-#### Needed final
ELE14-00993 Final9/10/20149/10/20149/10/2014 3:32:06 PMPPASS
Phone #: ###-#### Final ok
ELE13-03285 Rough-In Permanent Service9/9/20149/10/20149/10/2014 2:49:56 PMAFAIL
James Tully Phone #: ###-#### Checked interior breaker for proper type and size.
314.16 Number of Conductors in Outlet, Device, and
Junction Boxes, and Conduit Bodies. Boxes and conduit
bodies shall be of an approved size to provide free space
for all enclosed conductors.
(1) Bored Holes. In both exposed and concealed locations,
where a cable- or raceway-type wiring method is installed
through bored holes in joists, rafters, or wood members,
holes shall be bored so that the edge of the hole is not less
than 32 mm (11/4 in.) from the nearest edge of the wood
member. Where this distance cannot be maintained, the
cable or raceway shall be protected from penetration by
screws or nails by a steel plate(s) or bushing(s), at least
1.6 mm (1/16 in.) thick, and of appropriate length and width
installed to cover the area of the wiring.
All 15- and
20-ampere, 125- and 250-volt nonlocking-type receptacles
shall be listed weather-resistant type.
406.12 Tamper-Resistant Receptacles. Tamper-resistant
receptacles shall be installed as specified in 406.12(A)
through (C).
(A) Dwelling Units. In all areas specified in 210.52, all
nonlocking-type 125-volt, 15- and 20-ampere receptacles
shall be listed tamper-resistant receptacles
ELE14-02491 Final9/10/20149/10/20149/10/2014 2:04:53 PMPPASS
Final ok
ELE14-02491 Permanent Service9/9/20149/10/20149/10/2014 2:04:00 PMAPASS
Permanent service due to power being off for over 12 months Phone #: ###-#### Inspection requested via web by Chris Chesnut p/s o/h rec ok
ELE14-02517 Final9/10/20149/10/20149/10/2014 1:50:19 PMPPASS
Re energize, power off over a year. Call Eric with any questions. Phone #: ###-#### Inspection requested via web by Eric Schroeder p/s o/h rec ok
ELE14-02517 Final9/10/20149/10/20149/10/2014 1:49:49 PMPPASS
Re energize, power off over a year. Call Eric with any questions. Phone #: ###-#### Inspection requested via web by Eric Schroeder Final ok
ELE14-02461 Temporary Service9/9/20149/10/20149/10/2014 1:25:11 PMAPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton t/s o/h n ok
ELE14-02483 Electrical Rough-In9/10/20149/10/20149/10/2014 1:16:25 PMPPASS
Underground to cabinets and island bar Phone #: ###-#### Inspection requested via web by Stan Woodward Rough in ok cover
ELE14-02505 Conference9/9/20149/10/20149/10/2014 1:05:37 PMADONE
Please discuss with Joel the possibility of using NM cable in the conversion of the home to offices. ###-####. Thanks, Sean Phone #: ###-#### Inspection requested via web by Kevin Perez Informed contractor that any new wiring installed for house conversion to office space will have to be in conduit or armored cable as per BCC.
ELE14-02361 Electrical Rough-In9/9/20149/10/20149/10/2014 12:50:39 PMAPASS
pole bases, Steve Hook is contact at ###-####. thank you. Phone #: ###-#### Inspection requested via web by Debby Pierce N.W. 7 pole bases rough in ok cover
ELE14-02073 Final9/9/20149/10/20149/10/2014 12:36:24 PMAPASS
If you have any questions, please call the office. Thank you. Phone #: ###-#### Inspection requested via web by Clay Morgan Final ok
ELE14-01158 Final9/9/20149/10/20149/10/2014 12:10:50 PMANR
We are requesting a final inspection tomorrow morning on the canopy. Our onsite contact Bryant Adams, was hoping for a 1/2 hour notice prior to the inspection and he can be reached @ ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate Ramp not competed, exposed conduits shall be 24" under drive way. In use covers shall be installed on out door recepticals.
ELE14-03247 Permanent Service9/9/20149/10/20149/10/2014 12:00:00 AMPPASS
Dave. Permanent Service HMS2B. Phone #: ###-#### Inspection requested via web by Sean DeLacy Service located in N. E. corner of lot. p/s u/g n ok