ELE11-00558
| ELE-Aging Inspection | 9/10/2014 | 9/10/2014 | 9/11/2014 4:04:24 PM | | DONE |
|
|
shawn says can't get access. suggested going in backyard thru gate
|
ELE12-02449
| ELE-Aging Inspection | 9/10/2014 | 9/10/2014 | 9/11/2014 4:02:50 PM | | DONE |
|
|
final ok did drive by
|
ELE12-01040
| ELE-Aging Inspection | 9/10/2014 | 9/10/2014 | 9/11/2014 4:01:33 PM | | DONE |
|
|
still not ready
|
ELE12-01126
| ELE-Aging Inspection | 9/10/2014 | 9/10/2014 | 9/11/2014 4:00:51 PM | | DONE |
|
|
drove by and inspected final ok
|
ELE14-01620
| Final | 9/9/2014 | 9/10/2014 | 9/10/2014 4:55:10 PM | P | FAIL |
|
|
Chad Phone #: ###-#### 330.12(1) mc cable needs ul listed connectors and anti short bushins for transition to sealtite flex.
|
ELE14-01621
| Final | 9/9/2014 | 9/10/2014 | 9/10/2014 4:30:51 PM | P | FAIL |
|
|
Chad Phone #: ###-#### use correct overcurrent protection for heat pumps...330.12(1)- mc cable shall not be installed where subject to physical damage.. Label loadcenters upst. and dnst.
|
ELE14-02426
| Electrical Rough-In | 9/10/2014 | 9/10/2014 | 9/10/2014 3:44:29 PM | P | PASS |
|
|
Contact Travis Hust Phone #: ###-#### Inspection requested via web by Tom Betty r/i new bathroom ok
|
ELE14-02521
| Conference | 9/10/2014 | 9/10/2014 | 9/10/2014 3:15:23 PM | P | CANC |
|
|
Nate Phone #: ###-####-please call 30 minutes prior to meet requested re schedule with Nate
|
ELE14-02432
| Final | 9/9/2014 | 9/10/2014 | 9/10/2014 3:08:50 PM | A | NH |
|
|
This is for unit #''s 6 and 7, you only need access to unit #7, the tenant will meet you there, please call her Monica ###-#### When you are on your way. Thank You Phone #: ###-#### Inspection requested via web by Clay Morgan re schedule no access
|
ELE14-02432
| Electrical Rough-In | 9/9/2014 | 9/10/2014 | 9/10/2014 3:08:21 PM | A | NH |
|
|
This is for unit #''s 6 and 7, you only need access to unit #7, the tenant will meet you there, please call her Monica ###-#### When you are on your way. Thank You Phone #: ###-#### Inspection requested via web by Clay Morgan re schedule no access
|
ELE14-02507
| Permanent Service | 9/9/2014 | 9/10/2014 | 9/10/2014 3:03:18 PM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by kendall bender 310.15(B)(7)--service entrance conductors need to be rated 83%of service rating
|
ELE14-02507
| Electrical Rough-In | 9/9/2014 | 9/10/2014 | 9/10/2014 3:00:00 PM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by kendall bender 334.30 secure nm cable within 12in. of enclosure. 300.4 1/14in from edge of stud to bored holes or nm cable.
|
ELE14-00157
| Electrical Rough-In | 9/9/2014 | 9/10/2014 | 9/10/2014 2:19:21 PM | A | PASS |
|
|
4th floor Phone #: ###-#### Inspection requested via web by Tom Betty 4th floor north and east apts r/i ok
|
ELE14-02288
| Electrical Rough-In | 9/10/2014 | 9/10/2014 | 9/10/2014 1:22:23 PM | P | PASS |
|
|
New pharmacy in SW corner ceiling cover inspection. Phone #: ###-#### Inspection requested via web by Sean DeLacy r/i ceilings ok to cover
|
ELE14-02512
| Electrical Rough-In | 9/9/2014 | 9/10/2014 | 9/10/2014 1:08:10 PM | P | PASS |
|
|
trench cover inspection for feed from house to new structure Phone #: ###-#### Inspection requested via web by steve sellers u.ground ok to cover
|
ELE14-02510
| Final | 9/9/2014 | 9/10/2014 | 9/10/2014 12:57:48 PM | A | PASS |
|
|
Access code is 4062, Ground rod wire continues into crawl space to bond plumbing, plastic pipe entering house. Panel is in room off of garage. Phone #: ###-#### Inspection requested via web by Troy Cobb final ok
|
ELE14-02510
| Permanent Service | 9/10/2014 | 9/10/2014 | 9/10/2014 12:57:22 PM | P | PASS |
|
|
Access code is 4062, Ground rod wire continues into crawl space to bond plumbing, plastic pipe entering house. Panel is in room off of garage. Phone #: ###-#### Inspection requested via web by Troy Cobb p/s u/g rec ok
|
GCE13-00191
| GCE-Final | 9/9/2014 | 9/10/2014 | 9/10/2014 12:27:59 PM | A | PART |
|
|
Don ###-#### or office ###-#### final for rooms only partial final ok rms 172,174,176 and 178
|
GCE14-00143
| GCE-Temporary Service | 9/9/2014 | 9/10/2014 | 9/10/2014 12:00:00 AM | A | CANC |
|
|
Jim ###-#### temp service for burn demo
|
ELE14-02325
| Electrical Rough-In | 9/9/2014 | 9/10/2014 | 9/9/2014 11:52:01 AM | P | PASS |
|
|
UFER Phone #: ###-#### Inspection requested via web by steve ragan r/i ufer ok
|