ELE19-03395
| Temporary Service | 9/10/2019 | 9/10/2019 | 9/10/2019 4:44:50 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Cevyn Recla t/s u/g n ok
|
ELE19-03050
| Electrical Rough-In | 9/10/2019 | 9/10/2019 | 9/10/2019 4:12:13 PM | P | PASS |
|
|
We should be on site however please call in advance to just make sure we are there and can walk you through. Phone #: ###-#### Inspection requested via web by Casey Fouts Master floor heat rough in ok cover
|
ELE19-03380
| Conference | 9/9/2019 | 9/10/2019 | 9/10/2019 3:25:19 PM | P | DONE |
|
|
call for access- Justin Phone #: ###-#### Due to city ordinance and complaint 240 volt circuit located in basement must be removed and rendered unusable. Informed owner wire must be cut off where enters and panel and range box in basement. Call for inspection to verify and issue will be done.
|
ELE19-03312
| Final | 9/5/2019 | 9/10/2019 | 9/10/2019 3:00:09 PM | P | FAIL |
|
|
Apartment 201, top left. Compressor is on the north side of the building, right behind the Left Hand garage. The breaker panel is inside the apartment on an interior wall, so we ran 12/2 NM up into the attic and over to a j-box that''s on the end of EMT stubbed in from outside, and #12 wires from there down the outside of the bldg to the local disconnect. Phone #: ###-#### Inspection requested via web by Dan Hilke 300.10-This is for HVAC coated MC termination. MC shall terminate in KO with an approved connector listed for cable used. No answer at door to confirm 20 amp overcurrent device.
|
ELE19-03174
| Electrical Rough-In | 9/10/2019 | 9/10/2019 | 9/10/2019 2:36:19 PM | P | PASS |
|
|
Please call Mike Phone #: ###-#### Inspection requested via web by Kevin Perez Back kitchen wall, office and closet to right walls and hardlid, S.W. corner lid rough in ok cover.
|
ELE19-02151
| Final | 9/10/2019 | 9/10/2019 | 9/10/2019 2:02:41 PM | P | NH |
|
|
Phone #: ###-#### Inspection requested via web by John VanZandt Unit locked, contractor will call in when accessible.
|
ELE19-02492
| Electrical Rough-In | 9/10/2019 | 9/10/2019 | 9/10/2019 1:46:07 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Nick Smith Discussed GFCI protection, Tamper resistant, NM supports not to exceed 4 1/2', 60 amp minimum feed to garage with more than 2 circuits. Wiring ran on surface of upper plates and down side of studs to boxes. Explained all below 8' needs guard strips to protect from physical damage. Rough in ok.
|
ELE19-00991
| Final | 9/10/2019 | 9/10/2019 | 9/10/2019 1:16:29 PM | P | FAIL |
|
|
2010 Phone #: ###-#### Inspection requested via web by danny perrine 110.3- Devices shall be wired as per manufacturers instructions. Dine, island, master hall 3-ways mis-wire. One switch locks out other. Kitchen GFCI near sink will not hold. Dining receptacle to left of kitchen sink counter show hot gr. reversed. 410.16- Luminaires located in closet shall not have open bulbs. master closet.
|
ELE18-01935
| Final | 9/9/2019 | 9/10/2019 | 9/10/2019 11:45:26 AM | A | PART |
|
|
Final for Units 311, 312, 313, 314, and 315. Contact John (Homey) McElroy. Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek Units noted signed off in offce. TCO ok
|
ELE19-03260
| Final | 9/9/2019 | 9/10/2019 | 9/10/2019 10:43:13 AM | A | PASS |
|
|
The homeowner will be notified to have garage access. Phone #: ###-#### Inspection requested via web by Ashley Lanham Final ok
|
ELE19-01973
| Final | 9/9/2019 | 9/10/2019 | 9/10/2019 10:12:01 AM | A | FAIL |
|
|
IF it is locked there is a lock box in the 4 plex 9351 lock on the hand rail the code is 3600 Phone #: ###-#### Inspection requested via web by Neal Rumsey 300.10- Metellic raceways shall terminate in a box. Exposed conductors from flex connector to box with out sheathing in islands. * Access being added to each side. At time of inspection wiring visible from hole open. Wiring shall be protected from damage as per 320.23.
|
ELE19-01427
| Final | 9/9/2019 | 9/10/2019 | 9/10/2019 9:35:22 AM | A | NH |
|
|
Please contact when in route as no one is on site. Phone #: ###-#### Inspection requested via web by Cortney Hopper Called contact, no answer, left message. Due to being very short handed unable to wait around. Must recall.
|
ELE19-00689
| ELE-Request for Extension | 9/9/2019 | 9/10/2019 | 9/10/2019 9:15:08 AM | A | PASS |
|
|
Call ahead // Tim Phone #: ###-#### Just slow moving job. Extension ok.
|
ELE19-02176
| Final | 9/9/2019 | 9/10/2019 | 9/10/2019 9:12:19 AM | A | PASS |
|
|
electrical final at idaho Power. 9AM please call Phil 1 hour before so he can have a escort set up. Phone #: ###-#### Inspection requested via web by Deb Ipsen Occupancy card signed. Final ok
|
ELE19-03358
| Rough-In Permanent Service | 9/9/2019 | 9/10/2019 | 9/10/2019 8:34:29 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by David Nelson Rough in ok cover p/s u/g n ok
|