ELE13-02421
| Final | 9/11/2013 | 9/11/2013 | 9/11/2013 2:44:20 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by PAT MILLER ok final
|
ELE13-02500
| Temporary Service | 9/11/2013 | 9/11/2013 | 9/11/2013 2:43:10 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by kevin blackmon t/s u/g n ok
|
ELE13-02486
| Rough-In Permanent Service | 9/11/2013 | 9/11/2013 | 9/11/2013 2:42:15 PM | P | PASS |
|
|
Chris Phone #: ###-#### ri ok, p/s u/g n ok
|
ELE13-01796
| Final | 9/11/2013 | 9/11/2013 | 9/11/2013 2:35:24 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by ron spen cer ok final
|
ELE13-01796
| Final | 9/11/2013 | 9/11/2013 | 9/11/2013 2:00:54 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by ron spen cer ok final
|
ELE13-02454
| Rough-In Permanent Service | 9/10/2013 | 9/11/2013 | 9/11/2013 1:02:53 PM | P | PASS |
|
|
Clay Phone #: ###-#### p/s o/h rec ok
|
ELE13-01978
| Final | 9/11/2013 | 9/11/2013 | 9/11/2013 1:00:55 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Darryn Coburn corrections made, ok final
|
ELE13-02472
| Electrical Rough-In | 9/11/2013 | 9/11/2013 | 9/11/2013 12:26:29 PM | P | PASS |
|
|
please perform electrical rough for new tenant improvement Phone #: ###-#### >> Inspection requested via web by David Mackey walls only ok cover
|
ELE13-02204
| Rough-In Permanent Service | 9/11/2013 | 9/11/2013 | 9/11/2013 12:08:11 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Kurt Carlson ri ok, p/s u/g n ok
|
ELE13-02471
| Electrical Rough-In | 9/9/2013 | 9/11/2013 | 9/11/2013 10:19:57 AM | A | PASS |
|
|
cover inspection for back overhang where cables run through for new patio cover. Thank you! Phone #: ###-#### >> Inspection requested via web by Adam Staigle called, ri ok
|
ELE13-02471
| Final | 9/11/2013 | 9/11/2013 | 9/11/2013 10:19:39 AM | P | PASS |
|
|
cover inspection for back overhang where cables run through for new patio cover. Thank you! Phone #: ###-#### >> Inspection requested via web by Adam Staigle ok final
|
ELE13-02012
| Electrical Rough-In | 9/10/2013 | 9/11/2013 | 9/11/2013 9:40:20 AM | A | PASS |
|
|
Ceiling Cover. Danny on site Phone #: ###-#### >> Inspection requested via web by Buster Bowen ok cover ceiling
|
ELE13-02486
| Rough-In Permanent Service | 9/10/2013 | 9/11/2013 | 9/11/2013 8:54:15 AM | A | FAIL |
|
|
Cj is contact. Thank you. Phone #: ###-#### >> Inspection requested via web by Chris Chesnutcalled, left correction notice, NEC 680.25 feeder to panelboard shall be run in raceway if supplying branch circuits for pool equipment, 314.17(C) shall staple nm cable within 8" of box, 314.20 boxes shall be flush with finished surface in combustible walls, BCC shall change permit to minimum 25 rooms and add for pool
|
ELE13-02426
| Final | 9/10/2013 | 9/11/2013 | 9/11/2013 8:23:07 AM | A | PASS |
|
|
Need a final for the service and new range circuit. Home owner will be there. Phone #: ###-#### >> Inspection requested via web by John Edwards ok final
|
ELE13-02190
| Final | 9/10/2013 | 9/11/2013 | 9/11/2013 8:10:52 AM | A | PASS |
|
|
The key is under a rock by the Man Door, any questions or concerns please give me a call, thx, TW. Phone #: ###-#### >> Inspection requested via web by Stephen Kren ok final
|