ELE17-02482
| Electrical Rough-In | 9/11/2017 | 9/11/2017 | 9/11/2017 3:19:05 PM | P | PASS |
|
|
Garage rough in Phone #: ###-#### Inspection requested via web by John VanZandt Garage only rough in ok to cover
|
ELE17-02220
| Electrical Rough-In | 9/11/2017 | 9/11/2017 | 9/11/2017 2:33:16 PM | P | PART |
|
|
Rough inspection mail box station by office Phone #: ###-#### Inspection requested via web by Kenneth Chapman Disc means needed for seperate structure. 2 East bays of ceiling only. ok to cover.
|
ELE17-02246
| Final | 9/11/2017 | 9/11/2017 | 9/11/2017 2:00:05 PM | P | FAIL |
|
|
Access code is 7575 or 8080. Phone #: ###-#### Inspection requested via web by Paula Gratiot 314.20 Flush mounted Instalations. ( Wheather proof receps) 314.25 All boxes shall have covers or face plates.
|
ELE17-01344
| Final | 9/8/2017 | 9/11/2017 | 9/11/2017 1:25:14 PM | P | PASS |
|
|
garage code 1624 Phone #: ###-#### Inspection requested via web by Darryn Coburn Temp power final ok
|
ELE17-01940
| Final | 9/11/2017 | 9/11/2017 | 9/11/2017 1:24:41 PM | P | FAIL |
|
|
Final only 210.52 C 1 No point measured horizontaly along wall line shall be more than 24in from recep. ( Rt of cook top) Need lamps in Island Pend.
|
ELE17-01507
| Final | 9/8/2017 | 9/11/2017 | 9/11/2017 12:39:34 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Rick Beckman 210.52 A No point measured horizontaly shall be more than 24in from a recep. Rt of countertop back wall. 110.22 A Disc. shall be clearly identified. Both Furnaces and A/C's.
|
ELE17-02713
| Final | 9/11/2017 | 9/11/2017 | 9/11/2017 12:37:48 PM | P | PASS |
|
|
Approved plans onsite, please call homeowner before arrival to gain access, ###-####. Ryan King can answer questions Phone #: ###-#### Inspection requested via web by Ryan King Final ok
|
ELE17-02641
| Final | 9/7/2017 | 9/11/2017 | 9/11/2017 11:10:16 AM | A | PASS |
|
|
Call Ron upon arrival at the 17C lobby. Phone #: ###-#### Inspection requested via web by Ron Pontius Final ok
|
ELE17-02136
| Final | 9/8/2017 | 9/11/2017 | 9/11/2017 10:25:22 AM | A | FAIL |
|
|
Garage Code 3288 Phone #: ###-#### Inspection requested via web by Ben Grundhauser 210.52 A 2 1 Walls 2ft or more with countertop or similar work surfaces shall be considered wall space. (RT & LT of fireplace)
|
ELE17-02975
| Rough-In Permanent Service | 9/10/2017 | 9/11/2017 | 9/11/2017 9:56:25 AM | A | PASS |
|
|
Call with any questions Thank you Phone #: ###-#### Inspection requested via web by kim grundhauser Rough in ok p/s u/g n ok
|
ELE17-02896
| Final | 9/11/2017 | 9/11/2017 | 9/11/2017 9:46:01 AM | P | CANC |
|
|
Rough-in and Final Inspection Today. Call Micah at ###-#### for official meeting time. Thanks, James! Phone #: ###-#### >> Inspection requested via web by Jesse Simpson Inspection cancelled from web by: Jesse Simpson
|
ELE17-02713
| Final | 9/8/2017 | 9/11/2017 | 9/11/2017 9:34:09 AM | A | NH |
|
|
Approved plans onsite, please call homeowner before arrival to gain access, ###-####. Ryan King can answer questions. Phone #: ###-#### Inspection requested via web by Ryan King Wrong contact Number. No answer at alternative number and unable to leave message. Recall inspection
|