Inspections for the day of: Tuesday, September 11, 2018.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-04400 Final9/10/20189/11/20189/11/2018 4:09:20 PMPPASS
Inspection requested via web by Margie Rowe
MEC18-04361 Rough-in9/10/20189/11/20189/11/2018 3:35:43 PMPFAIL
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- crawl needs completed- b vent insulation shield on water heater needs to go all the way to roof- missing firecaulk on fireplace flue big hole on bottom- 6" fresh air can not come from roof- dryer vent needs supported every 4 feet and seal where penetrates into dryer box in wall- need to fix all rips and tears on arma flex on lineset- reinspection fee issued-( same ongoing correction on house R/I inspections)
MEC18-04361 Pressure Test9/10/20189/11/20189/11/2018 3:29:29 PMPPASS
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass
MEC18-04360 Pressure Test9/10/20189/11/20189/11/2018 3:28:41 PMPPASS
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass
MEC18-04360 Rough-in9/10/20189/11/20189/11/2018 3:28:13 PMPFAIL
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- fix all rips and tears on lineset- water heater b vent insulation shield needs to go to roof to short- fireplace flue does not have clearances per manufactures install at thimble to exterior, framing not big enough- need to seal fresh air seams on damper- need to support dryer vent every 4 feet- left correction notice front of furnace- reinspection fee issued (same ongoing corrections on house R/I inspections)
MEC18-04386 Final9/7/20189/11/20189/11/2018 2:59:21 PMPPASS
installer Archie ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil cok ok
MEC18-04412 Final9/10/20189/11/20189/11/2018 2:09:01 PMPPASS
Phone #: ###-#### Inspection requested via web by Konrad Swartz- heat pump ok
MEC18-04398 Card not on site to sign9/11/20189/11/20189/11/2018 1:19:21 PMPPASS
no card to sign
MEC18-04398 Final9/10/20189/11/20189/11/2018 1:18:51 PMPPASS
Please call technician 30 minutes ahead for access: ###-#### Phone #: ###-#### Inspection requested via web by Melissa Skinner- seal on duct ok- exhaust duct ok- registers and flex ok
MEC18-04212 Rough-in9/11/20189/11/20189/11/2018 11:34:35 AMPCANC
need inspection for cover for new ductwork Phone #: ###-#### Inspection requested via web by Brett Shannon- per phone call with Brett- will reschedule when man J is issued
MEC18-00840 Final9/11/20189/11/20189/11/2018 11:06:35 AMPPASS
Field Super Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney- final ok
MEC18-04405 Pressure Test9/11/20189/11/20189/11/2018 10:29:08 AMANR
pool person onsite saying riser in wrong location at pump house- recall in inspection and retest system when issue resolved
MEC18-03409 Final9/10/20189/11/20189/11/2018 9:55:00 AMAPASS
Final
Gas Fireplace Final Also
Garage Code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart- final ok
MEC18-03410 Final9/11/20189/11/20189/11/2018 9:54:39 AMAPASS
fireplace final ok
MEC18-04410 Final9/10/20189/11/20189/11/2018 9:05:01 AMAPASS
customer would like 9:00 Phone #: ###-#### Inspection requested via web by Kim Lithander- furnace a/c coil co ok- no gas test at this address was for flue test
MEC18-04410 Pressure Test9/11/20189/11/20189/11/2018 9:04:03 AMAPASS
Kim Phone #: ###-####- 5lb flue test pass
MEC16-04975 Mec-Aging Inspection9/11/20189/11/20189/11/2018 8:26:08 AM CANC
no calls
MEC16-04976 Mec-Aging Inspection9/11/20189/11/20189/11/2018 8:25:54 AM CANC
no calls
MEC17-05556 Mec-Aging Inspection9/11/20189/11/20189/11/2018 8:21:33 AM FAIL
needs called in for final inspection
MEC18-04212 Rough-in9/8/20189/11/20189/10/2018 6:14:17 PMACANC
Need approve to cover for ductwork, call me, Brett with any questions 2089066928 Phone #: ###-#### >> Inspection requested via web by Brett Shannon Inspection cancelled from web by: Brett Shannon