MEC18-04400
| Final | 9/10/2018 | 9/11/2018 | 9/11/2018 4:09:20 PM | P | PASS |
|
|
Inspection requested via web by Margie Rowe
|
MEC18-04361
| Rough-in | 9/10/2018 | 9/11/2018 | 9/11/2018 3:35:43 PM | P | FAIL |
|
|
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- crawl needs completed- b vent insulation shield on water heater needs to go all the way to roof- missing firecaulk on fireplace flue big hole on bottom- 6" fresh air can not come from roof- dryer vent needs supported every 4 feet and seal where penetrates into dryer box in wall- need to fix all rips and tears on arma flex on lineset- reinspection fee issued-( same ongoing correction on house R/I inspections)
|
MEC18-04361
| Pressure Test | 9/10/2018 | 9/11/2018 | 9/11/2018 3:29:29 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass
|
MEC18-04360
| Pressure Test | 9/10/2018 | 9/11/2018 | 9/11/2018 3:28:41 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass
|
MEC18-04360
| Rough-in | 9/10/2018 | 9/11/2018 | 9/11/2018 3:28:13 PM | P | FAIL |
|
|
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- fix all rips and tears on lineset- water heater b vent insulation shield needs to go to roof to short- fireplace flue does not have clearances per manufactures install at thimble to exterior, framing not big enough- need to seal fresh air seams on damper- need to support dryer vent every 4 feet- left correction notice front of furnace- reinspection fee issued (same ongoing corrections on house R/I inspections)
|
MEC18-04386
| Final | 9/7/2018 | 9/11/2018 | 9/11/2018 2:59:21 PM | P | PASS |
|
|
installer Archie ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace a/c coil cok ok
|
MEC18-04412
| Final | 9/10/2018 | 9/11/2018 | 9/11/2018 2:09:01 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Konrad Swartz- heat pump ok
|
MEC18-04398
| Card not on site to sign | 9/11/2018 | 9/11/2018 | 9/11/2018 1:19:21 PM | P | PASS |
|
|
no card to sign
|
MEC18-04398
| Final | 9/10/2018 | 9/11/2018 | 9/11/2018 1:18:51 PM | P | PASS |
|
|
Please call technician 30 minutes ahead for access: ###-#### Phone #: ###-#### Inspection requested via web by Melissa Skinner- seal on duct ok- exhaust duct ok- registers and flex ok
|
MEC18-04212
| Rough-in | 9/11/2018 | 9/11/2018 | 9/11/2018 11:34:35 AM | P | CANC |
|
|
need inspection for cover for new ductwork Phone #: ###-#### Inspection requested via web by Brett Shannon- per phone call with Brett- will reschedule when man J is issued
|
MEC18-00840
| Final | 9/11/2018 | 9/11/2018 | 9/11/2018 11:06:35 AM | P | PASS |
|
|
Field Super Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney- final ok
|
MEC18-04405
| Pressure Test | 9/11/2018 | 9/11/2018 | 9/11/2018 10:29:08 AM | A | NR |
|
|
pool person onsite saying riser in wrong location at pump house- recall in inspection and retest system when issue resolved
|
MEC18-03409
| Final | 9/10/2018 | 9/11/2018 | 9/11/2018 9:55:00 AM | A | PASS |
|
|
Final Gas Fireplace Final Also Garage Code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart- final ok
|
MEC18-03410
| Final | 9/11/2018 | 9/11/2018 | 9/11/2018 9:54:39 AM | A | PASS |
|
|
fireplace final ok
|
MEC18-04410
| Final | 9/10/2018 | 9/11/2018 | 9/11/2018 9:05:01 AM | A | PASS |
|
|
customer would like 9:00 Phone #: ###-#### Inspection requested via web by Kim Lithander- furnace a/c coil co ok- no gas test at this address was for flue test
|
MEC18-04410
| Pressure Test | 9/11/2018 | 9/11/2018 | 9/11/2018 9:04:03 AM | A | PASS |
|
|
Kim Phone #: ###-####- 5lb flue test pass
|
MEC16-04975
| Mec-Aging Inspection | 9/11/2018 | 9/11/2018 | 9/11/2018 8:26:08 AM | | CANC |
|
|
no calls
|
MEC16-04976
| Mec-Aging Inspection | 9/11/2018 | 9/11/2018 | 9/11/2018 8:25:54 AM | | CANC |
|
|
no calls
|
MEC17-05556
| Mec-Aging Inspection | 9/11/2018 | 9/11/2018 | 9/11/2018 8:21:33 AM | | FAIL |
|
|
needs called in for final inspection
|
MEC18-04212
| Rough-in | 9/8/2018 | 9/11/2018 | 9/10/2018 6:14:17 PM | A | CANC |
|
|
Need approve to cover for ductwork, call me, Brett with any questions 2089066928 Phone #: ###-#### >> Inspection requested via web by Brett Shannon Inspection cancelled from web by: Brett Shannon
|