ELE06-02332
| Final | 9/12/2006 | 9/12/2006 | 9/12/2006 4:30:19 PM | P | FAIL |
|
|
spencer; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie--call 1st for access called, left corr notice, nec 410.4(D) up bath fixture shall be listed as suitable for damp location by shaower, 314.21 boxes with flush type covers shall have drywall repaired so no gap over 1/8" at edge of box (out front and microwave), 406.5, 404.9 faceplates shall seat against mounting surface,BCC all make-up shall be done - disposal installed tile in bath for recpt?
|
ELE06-02550
| Final | 9/12/2006 | 9/12/2006 | 9/12/2006 3:49:45 PM | P | FAIL |
|
|
spencer; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie--call 1st for access called, left corr notice, nec 250.53(G) electrode shall be flush with or below ground ,406.5&404.9 faceplates shall seat against mounting surface, 406.4 recpts shall be securely fastened in place, 404.4 switch shall not be installed in tub space, BCC tile work shall be done in bath
|
ELE06-02024
| Final | 9/12/2006 | 9/12/2006 | 9/12/2006 3:26:29 PM | P | FAIL |
|
|
spencer; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie--call 1st for access called, left corr notice, nec 406.4(D) recpt faces shall be flush with or project from faceplates(all), 406.4 recpts shall be securely fastened in place(garage), 406.5&404.9 faceplates shall seat against mounting surface,BCC all make-up shall be done(ac)
|
ELE06-01778
| Final | 9/12/2006 | 9/12/2006 | 9/12/2006 2:56:50 PM | A | FAIL |
|
|
solar post light Internet Inspection Request from: Melyne Davis called, left message, left corr notice, nec 406.5 & 404.9 faceplates shall seat against mounting surface,406.4 recpt faces shall be flush with or project from faceplates,Bcc all make-up shall be done-mbr lites shall operate, 3-way switch up hall shall operate, garage gfci to left of panel shall operate
|
ELE06-01866
| Final | 9/11/2006 | 9/12/2006 | 9/12/2006 2:20:44 PM | P | PASS |
|
|
calvin; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok to final
|
ELE06-03301
| Rough-In Permanent Service | 9/12/2006 | 9/12/2006 | 9/12/2006 1:44:56 PM | P | PASS |
|
|
darrin; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ric ok, p/s u/g n ok
|
ELE06-01438
| Permanent Service | 9/11/2006 | 9/12/2006 | 9/12/2006 11:04:11 AM | A | FAIL |
|
|
daniel - call prior to insp for access; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley called, left corr notice, nec 250.24(A)(1) gec shall be connected to terminal or bus to which the grounded service conductor is connected at the service, 310.4 paralled conductors shall be electrically joined at both ends, 110.12(A) unused openings shall be closed, 312.5 abrasion protection shall be provided for all conductors entering enclosure,250.53(G) rods shall be flush with surface, BCC all make-up shall be done, taping for phases done, Note: no access to inside, could determine more corrections
|
ELE06-02887
| Rough-In Permanent Service | 9/11/2006 | 9/12/2006 | 9/12/2006 10:48:46 AM | A | PART |
|
|
Site underground inspection.; Phone #: ###-#### Internet Inspection Request from: Tina Payne north 1/2 u/g for site liting ok to cover
|
ELE06-03241
| Final | 9/11/2006 | 9/12/2006 | 9/12/2006 10:23:30 AM | A | PASS |
|
|
Butch, call 1st b4 going out; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt ok to final
|
ELE06-02741
| Final | 9/11/2006 | 9/12/2006 | 9/12/2006 10:13:55 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 9/11/2006 at 6:36:27 PM. Contact: ###-####. ok to final
|
ELE06-03390
| Final | 9/11/2006 | 9/12/2006 | 9/12/2006 10:00:00 AM | A | PASS |
|
|
Jason; Phone #: ###-#### Internet Inspection Request from: Matt Santacruz ok to final
|
ELE06-02464
| Final | 9/12/2006 | 9/12/2006 | 9/12/2006 9:22:06 AM | A | PART |
|
|
Phone #: ###-#### Internet Inspection Request from: Jim Williams ok to final
|
ELE06-03178
| Electrical Rough-In | 9/11/2006 | 9/12/2006 | 9/12/2006 9:02:18 AM | A | PASS |
|
|
ANY QUESTIONS PLEASE CALL JESSIE COLLINGSWORTH; Phone #: ###-#### Internet Inspection Request from: Jeff Radford walls only ok to cover
|
ELE06-00113
| Electrical Rough-In | 9/11/2006 | 9/12/2006 | 9/12/2006 8:48:41 AM | A | PART |
|
|
This is for a ceiling rough-in inspection. Contact Greg Pack ; Phone #: ###-#### Internet Inspection Request from: Shelli Daylong ok to cover anop
|