ELE06-04686
| ELE-Aging Inspection | 9/12/2008 | 9/12/2008 | 9/18/2008 10:29:13 AM | | DONE |
|
|
contractor still needs to call
|
ELE08-02514
| Electrical Rough-In | 9/11/2008 | 9/12/2008 | 9/12/2008 4:12:04 PM | P | NR |
|
|
hume Phone #: ###-#### met electrician, his work was ready, except homeowner wants to change kitchen overhead lighting, which will force open more sheetrock. Will inspect all at once , no esc this project
|
ELE07-03307
| Permanent Service | 9/11/2008 | 9/12/2008 | 9/12/2008 3:37:53 PM | A | PASS |
|
|
CONTACT: NEIL RAMSEY Phone #: ###-#### Internet Inspection Request from: Deb Gooden p/s u/g n ok, 1 meter only, could not add esc response
|
ESC07-01189
| General Inspection | 9/12/2008 | 9/12/2008 | 9/12/2008 3:36:35 PM | P | PART |
|
|
looked ok
|
ESC08-00175
| General Inspection | 9/12/2008 | 9/12/2008 | 9/12/2008 3:35:37 PM | P | PART |
|
|
looked ok
|
ESC08-00365
| General Inspection | 9/12/2008 | 9/12/2008 | 9/12/2008 3:33:34 PM | P | PART |
|
|
looked ok
|
ELE08-00246
| Final | 9/12/2008 | 9/12/2008 | 9/12/2008 3:13:27 PM | P | FAIL |
|
|
Lars Phone #: ###-#### called, left correction notice, NEC 408.4 circuit directory shall be fully explanatory for each circuit, 410.16(C) edge of closet luninaire shall be minimum 6" from front of shelf, 406.4 laundry room receptacle shall be securely mounted, 110.3(B) listed equipment shall be installed per manufacturers instructions-upper bath receptacle show reverse polarity, other bath gfci won't set, 422.32 shall provide dishwasher circuit i.d. and disconnecting means, rest ok
|
ELE08-01956
| Electrical Rough-In | 9/12/2008 | 9/12/2008 | 9/12/2008 2:18:27 PM | P | PART |
|
|
todd - underground Phone #: ###-#### ok to cover u/g north side building, and about 30' going to south on east side, need to see depth going to planter area east side
|
ELE08-02468
| Final | 9/12/2008 | 9/12/2008 | 9/12/2008 1:23:34 PM | P | PASS |
|
|
I''ll be there at noon. Phone #: ###-#### Internet Inspection Request from: Andy Derrick ok to final
|
ELE08-02373
| Final | 9/12/2008 | 9/12/2008 | 9/12/2008 12:45:34 PM | P | PASS |
|
|
Any questions please contact Mark Kinch. Phone #: ###-#### Internet Inspection Request from: Vicki Moore ok to final, no card to sign, called contractor about card, no esc this project
|
ELE08-01956
| Electrical Rough-In | 9/11/2008 | 9/12/2008 | 9/12/2008 8:58:07 AM | A | CANC |
|
|
todd - underground Phone #: ###-#### called contractor, he needs pm inspection since not far enough along for am
|
ELE08-02439
| Permanent Service | 9/11/2008 | 9/12/2008 | 9/12/2008 8:46:01 AM | A | PASS |
|
|
del - first call Phone #: ###-#### p/s o/h rec (new) ok, no esc this project
|
ELE08-02380
| Final | 9/11/2008 | 9/12/2008 | 9/12/2008 8:11:39 AM | A | NR |
|
|
Scheduled by a contractor via Hello! on 9/11/2008 at 9:54:04 PM. Contact: ###-####. see failed ri, fee due
|
ELE08-02380
| Electrical Rough-In | 9/11/2008 | 9/12/2008 | 9/12/2008 8:04:12 AM | A | FAIL |
|
|
Stu- ceiling Phone #: ###-#### met electrician, left correction notice, NEC 725.25 abandoned class 2,3,PLTC cables shall be removed, 300.11(A) shall securely support raceways and cable assemblies, 348.30(A) shall securely support fmc within 12" of termination,358.30(A) shall securely support emt within 3' of termination, BCC no violations shall be retained, no cables or raceways shall be supported by grid or tiles, no esc this project
|