ESC13-00401
| General Inspection | 9/12/2013 | 9/12/2013 | 9/13/2013 4:58:55 PM | | CANC |
|
|
|
ESC12-00373
| Aging Inspection | 9/12/2013 | 9/12/2013 | 9/13/2013 4:55:37 PM | | PASS |
|
|
|
ESC12-00380
| Aging Inspection | 9/12/2013 | 9/12/2013 | 9/13/2013 4:51:32 PM | | PASS |
|
|
|
PLM13-01998
| Final | 9/11/2013 | 9/12/2013 | 9/12/2013 4:54:18 PM | P | PART |
|
|
Final Inspection Phone #: ###-#### >> Inspection requested via web by Marion Moody need six inches of clearance for single wall pipe on water heater vent contractor to recall when ready
|
PLM13-01792
| Final | 9/12/2013 | 9/12/2013 | 9/12/2013 4:36:03 PM | P | PASS |
|
|
The lav in the bathroom is now installed complete with mixing valves Thanks Phone #: ###-#### >> Inspection requested via web by MICHAEL BYERS
|
PLM13-02342
| Final | 9/12/2013 | 9/12/2013 | 9/12/2013 3:47:48 PM | P | PASS |
|
|
MH Hook up Phone #: ###-#### >> Inspection requested via web by Richard Estes
|
PLM13-02252
| Water and/or Sewer | 9/11/2013 | 9/12/2013 | 9/12/2013 3:06:47 PM | A | PART |
|
|
water line only...will be ready at 10am...Bob will be on site..his number is above..Thank you!! Phone #: ###-#### >> Inspection requested via web by susan love water line test ok ok to cover
|
PLM13-02499
| Water and/or Sewer | 9/12/2013 | 9/12/2013 | 9/12/2013 1:48:50 PM | P | PASS |
|
|
>> Inspection requested via web by James Fife
|
PLM13-02499
| DOC - Permit Finaled | 9/12/2013 | 9/12/2013 | 9/12/2013 1:48:37 PM | P | PASS |
|
|
>> Inspection requested via web by James Fife
|
PLM13-01633
| Final | 9/11/2013 | 9/12/2013 | 9/12/2013 12:52:54 PM | P | PASS |
|
|
JOB # 16928. Phone #: ###-#### >> Inspection requested via web by Ann Marie Reyes
|
PLM13-02529
| Water and/or Sewer | 9/12/2013 | 9/12/2013 | 9/12/2013 12:52:19 PM | P | PART |
|
|
Jody Phone #: ###-#### water line installed as per conversation with inspector 380 and contractor rescheduled inspection for 9-16-13 for Eric to final
|
PLM13-02512
| Plumbing Rough-in | 9/12/2013 | 9/12/2013 | 9/12/2013 12:38:05 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by David Stephenson
|
PLM13-02525
| Plumbing Rough-in | 9/11/2013 | 9/12/2013 | 9/12/2013 12:36:56 PM | A | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Steve Spence test failed on D W V need to retest contractor to recall when ready correction notice on site
|
PLM13-02500
| Plumbing Rough-in | 9/11/2013 | 9/12/2013 | 9/12/2013 12:06:21 PM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Frank Young
|
PLM13-02522
| Water and/or Sewer | 9/11/2013 | 9/12/2013 | 9/12/2013 12:04:30 PM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Darren Wood
|
PLM13-02522
| Water and/or Sewer | 9/12/2013 | 9/12/2013 | 9/12/2013 12:04:11 PM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Darren Wood
|
PLM13-02526
| Plumbing Rough-in | 9/11/2013 | 9/12/2013 | 9/12/2013 10:47:15 AM | A | PASS |
|
|
test is on thanks Phone #: ###-#### >> Inspection requested via web by robert goodson
|
PLM13-02524
| Plumbing Rough-in | 9/11/2013 | 9/12/2013 | 9/12/2013 10:37:38 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by sandy moncarr
|
PLM13-01990
| Final | 9/11/2013 | 9/12/2013 | 9/12/2013 10:13:48 AM | A | PASS |
|
|
Call for lock box code. Thanks Phone #: ###-#### >> Inspection requested via web by Jason Gonzalez
|
PLM13-02487
| Plumbing Rough-in | 9/11/2013 | 9/12/2013 | 9/12/2013 9:51:40 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Todd Walter
|
PLM13-02496
| Plumbing Rough-in | 9/11/2013 | 9/12/2013 | 9/12/2013 8:37:59 AM | A | PASS |
|
|
second floor rest room,s rough-in ok ok to cover
|
PLM13-01768
| Final | 9/11/2013 | 9/12/2013 | 9/12/2013 8:36:53 AM | A | PASS |
|
|
JOB # 16952. Phone #: ###-#### >> Inspection requested via web by Ann Marie Reyes
|
PLM13-02506
| DOC - Permit Finaled | 9/12/2013 | 9/12/2013 | 9/12/2013 7:28:23 AM | A | PASS |
|
|
please call first 941 4484 >> Inspection requested via web by john brown
|