ELE12-02460
| ELE-Aging Inspection | 9/12/2014 | 9/12/2014 | 9/18/2014 4:25:50 PM | | DONE |
|
|
Waiting on owner
|
ELE14-02365
| Rough-In Permanent Service | 9/12/2014 | 9/12/2014 | 9/12/2014 3:31:18 PM | P | PASS |
|
|
Daryl knows about this one, any questions please let me know, thx, TW. Phone #: ###-#### Inspection requested via web by Stephen Kren Service available fault current 18k rough in ok p/s u/g n ok
|
ELE14-01194
| Final | 9/12/2014 | 9/12/2014 | 9/12/2014 3:05:27 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI Laundry area left GFCI line/ load reversed, 3 GFI to right shall be tamper resistant type. AC #2 20 amp max fuse. Fix post light cover and photo cell
|
ELE14-02501
| Final | 9/12/2014 | 9/12/2014 | 9/12/2014 2:11:47 PM | P | PASS |
|
|
AJ Phone #: ###-#### Final ok
|
ELE14-02544
| Conference | 9/11/2014 | 9/12/2014 | 9/12/2014 11:21:57 AM | P | DONE |
|
|
Phone #: ###-#### Inspection requested via web by Jim Williams Discussed code requirement for service change. Overhead swing not passing over more than 3' of roof 3' clearance is all that should be needed, replace range and dryer circiut to 4-wire, relocate service from existing location to provide flat work space.
|
ELE14-02544
| Final | 9/12/2014 | 9/12/2014 | 9/12/2014 11:21:37 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jim Williams Permit created for conference only Final ok
|
ELE14-02444
| Electrical Rough-In | 9/11/2014 | 9/12/2014 | 9/12/2014 10:45:21 AM | P | CANC |
|
|
Please call before arriving to confirm site is ready for inspection. Phone #: ###-#### >> Inspection requested via web by Todd Sellman Inspection cancelled from web by: Kristal Soland
|
ELE14-02542
| Final | 9/11/2014 | 9/12/2014 | 9/12/2014 10:41:09 AM | A | PASS |
|
|
Jason Gaythwaite is our contact ###-#### Phone #: ###-#### Inspection requested via web by Kelly Felin Final ok
|
ELE14-02542
| Electrical Rough-In | 9/12/2014 | 9/12/2014 | 9/12/2014 10:26:42 AM | P | PASS |
|
|
Jason Gaythwaite is our contact ###-#### Phone #: ###-#### Inspection requested via web by Kelly Felin AC rough in ok
|
ELE14-02280
| Permanent Service | 9/11/2014 | 9/12/2014 | 9/12/2014 10:12:42 AM | A | PASS |
|
|
inspection for permanent service for Idaho power connection. contact ####-#### andy. Phone #: ###-#### Inspection requested via web by andrew dopieralski Storage facillity, service in south east corner of lot. p/s u/g n ok
|
ELE14-01963
| Electrical Rough-In | 9/12/2014 | 9/12/2014 | 9/12/2014 9:36:34 AM | A | PASS |
|
|
Underground feeders on the utility side. Phone #: ###-#### Inspection requested via web by Rafael Castillo Rough in ok cover
|
ELE14-02177
| Electrical Rough-In | 9/10/2014 | 9/12/2014 | 9/12/2014 9:13:45 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton 2 bathrooms and dividing wall by electrical room rough in ok cover
|
ELE14-02003
| Final | 9/11/2014 | 9/12/2014 | 9/12/2014 8:57:53 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Thomas Jenkins Final ok
|