MEC18-01830
| Final | 9/12/2018 | 9/12/2018 | 9/12/2018 2:14:39 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Kim Evans- lineset needs 6" clearance to single wall wye branch or replace with b vent wye- need to seal gas line penetration at exterior of house
|
MEC18-01831
| Final | 9/12/2018 | 9/12/2018 | 9/12/2018 2:12:58 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Kim Evans- lineset and gas piping need sealed at exterior of house
|
MEC18-04360
| Rough-in | 9/12/2018 | 9/12/2018 | 9/12/2018 1:43:10 PM | P | FAIL |
|
|
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- corrections not made- reinspection fee issued for ongoing corrections on house R/Is
|
MEC18-04361
| Rough-in | 9/12/2018 | 9/12/2018 | 9/12/2018 1:42:14 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- R/I ok- need to seal dryer duct where penetrstes dryer box by final
|
MEC18-03460
| Rough-in | 9/12/2018 | 9/12/2018 | 9/12/2018 11:36:47 AM | A | PASS |
|
|
We will be ready by 10:00 Phone #: ###-#### Inspection requested via web by Drew Tverdy- light test pass on smoker- ok fir fire wrap
|
MEC18-04198
| Final | 9/6/2018 | 9/12/2018 | 9/12/2018 11:11:43 AM | A | PASS |
|
|
Homeowner gave Brian permission to enter property to look at electrical box Phone #: ###-#### Inspection requested via web by Mary LaFayette-
|
MEC18-04434
| Pressure Test | 9/11/2018 | 9/12/2018 | 9/12/2018 10:36:46 AM | A | PASS |
|
|
LINE IS PRESSURED AND READY- PLEASE CALL TENANT RAIN WHEN 30 MINS IN ROUTE, IF GAS PRESSURES PLEASE TAG FOR INTERMOUNTAIN GAS AND FINAL OUT Phone #: ###-#### Inspection requested via web by Rick Montgomery- 20lb gas pass existing system- tagged meter
|
MEC18-04419
| Rough-in | 9/11/2018 | 9/12/2018 | 9/12/2018 10:25:20 AM | A | PART |
|
|
please call Kirk prior to going over so I can meet you there is a lock box on the door 2769 code also there is a gate around the building but not locked a bungee cord is holding it closed Phone #: ###-#### Inspection requested via web by Kirk Johns- seal on duct ok- ok to insulate- missing 2 supplies to bsthrooms and hallway- missing a few transfer grills- need 1 inch clearance on insulation shields on flue- Kirk checking with engineer about these items-
|
MEC18-04419
| Pressure Test | 9/11/2018 | 9/12/2018 | 9/12/2018 10:23:25 AM | A | PASS |
|
|
please call Kirk prior to going over so I can meet you there is a lock box on the door 2769 code also there is a gate around the building but not locked a bungee cord is holding it closed Phone #: ###-#### Inspection requested via web by Kirk Johns- 20lb gas pass
|