Inspections for the day of: Wednesday, September 12, 2018.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-03332 Final9/11/20189/12/20189/12/2018 3:51:16 PMPFAIL
Please call Charene prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- A/C fuse size too large
MEC18-03811 Rough-in9/12/20189/12/20189/12/2018 2:56:36 PMPPART
105,106,205,206,305,306 Phone #: ###-#### Inspection requested via web by Gary Reeves
-R/I ok
MEC18-04433 Final9/11/20189/12/20189/12/2018 2:53:54 PMPNH
PLEASE CALL OUR LEAD INSTALLER JOHNNY WHEN 30 MINS IN ROUTE, END OF DAY WOULD BE PREFERABLE IF AT ALL POSSIBLE. THANKS SO MUCH Phone #: ###-#### Inspection requested via web by Rick Montgomery
- no access to home
MEC18-04229 Rough-in9/12/20189/12/20189/12/2018 2:14:30 PMPPASS
Cas Lawler point of contact. Please call 30 min prior to inspection Phone #: ###-#### Inspection requested via web by Sheldon Lebow- vent piping clearances ok- framing around vent pipe ok- R/I ok
MEC18-04394 Rough-in9/12/20189/12/20189/12/2018 1:45:27 PMPFAIL
CLINT ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- horizantal vent piping running in the attic is covered by cardboard box looks like its being used as a insulation sheild- need to see piping for clearances to combustibles and a different type of sheild used
MEC18-04366 Final9/11/20189/12/20189/12/2018 1:12:16 PMPPASS
The customer would prefer early afternoon sometime between 12:00 PM and 3:00 PM. Please call her when on way: Betty ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss
- furnace ac coil co ok
MEC17-05578 Mec-Aging Inspection9/12/20189/12/20189/12/2018 12:54:59 PM FAIL
need to reschedule inspection with homeowner
MEC18-04164 Final9/11/20189/12/20189/12/2018 11:41:31 AMAPASS
customer would like 8:00 Phone #: ###-#### Inspection requested via web by Kim Lithander- A/C coil co ok
MEC18-04423 Rough-in9/11/20189/12/20189/12/2018 11:20:35 AMAPART
Anytime is fine. Thanks! Inspection requested via web by Floyd Floyd Peek- there is still alot of work left for a full R/I- dryer vent piping ok still need to see backdraft damper- exhaust fan ok- call in inspection when the rest of the R/I is finished
(office space on south side duct work, ductless split)
MEC18-04425 Final9/11/20189/12/20189/12/2018 10:40:00 AMAPASS
PLEASE CALL ZACH THE PROJECT MANAGER WHEN 30 MINS IN ROUTE Phone #: ###-#### Inspection requested via web by Rick Montgomery- all fusible link dampers ok- 2 smoke detectors ok- ok for cover