ELE11-01935
| Electrical Rough-In | 9/12/2011 | 9/13/2011 | 9/13/2011 3:32:42 PM | P | PASS |
|
|
rod - after 3:00 please Phone #: ###-#### rough-in ok cover garage/family room addition
|
ESC11-00003
| Aging Inspection | 9/13/2011 | 9/13/2011 | 9/13/2011 2:29:16 PM | | PASS |
|
|
see final
|
ESC11-00003
| Site Final | 9/13/2011 | 9/13/2011 | 9/13/2011 2:28:53 PM | P | PASS |
|
|
Landscaping in siteclean, construction completed final ok
|
ELE11-01986
| Final | 9/13/2011 | 9/13/2011 | 9/13/2011 2:06:07 PM | P | PASS |
|
|
Lockbox code on storage container for front door. 1345 Phone #: ###-#### >> Inspection requested via web by Lynn Cable final ok
|
ELE11-02073
| Final | 9/12/2011 | 9/13/2011 | 9/13/2011 1:29:24 PM | P | PASS |
|
|
All I did here was move a two gang switch box from wall where dressing room is now. Owner or employees of Idaho Running Company can show you where the newly relocated switches are in back. Thanks, Mark Phone #: ###-#### >> Inspection requested via web by Mark Hennequin final ok
|
ELE11-01702
| Electrical Rough-In | 9/13/2011 | 9/13/2011 | 9/13/2011 1:06:29 PM | P | FAIL |
|
|
Installed wiring for new furnace and heat pump. Any questions call Jake @ ###-#### Call Melissa @###-#### to meet to be let in. Phone #: ###-#### >> Inspection requested via web by Andy Rose Shall provide GFCI protected service receptacle for outdoor unit, strap sealtite at heatpump, strap flex at furnace
|
ELE11-02088
| Temporary Service | 9/13/2011 | 9/13/2011 | 9/13/2011 12:28:03 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Tracy Robertson t/s u/g n ok 100 ampere power to job trailor
|
ELE11-01960
| Final | 9/13/2011 | 9/13/2011 | 9/13/2011 12:04:55 PM | P | PASS |
|
|
trent Phone #: ###-#### final ok
|
ELE11-01968
| Final | 9/12/2011 | 9/13/2011 | 9/13/2011 10:28:06 AM | A | PASS |
|
|
Salon should be open Tuesday from 9 am to 5 pm. Phone #: ###-#### >> Inspection requested via web by Pete Campbell final ok
|
ELE11-02099
| Electrical Rough-In | 9/12/2011 | 9/13/2011 | 9/13/2011 9:39:09 AM | A | PASS |
|
|
Richard Phone #: ###-#### rough-in ok ok cover garage addition- storage area
|
ELE10-02132
| Permanent Service | 9/12/2011 | 9/13/2011 | 9/13/2011 9:21:11 AM | A | PASS |
|
|
Call Troy with questions ###-#### Phone #: ###-#### >> Inspection requested via web by Don Conley p/s o/h rec ok
|
GCE11-00053
| GCE-Final | 9/12/2011 | 9/13/2011 | 9/13/2011 9:07:08 AM | A | PASS |
|
|
Aaron @ ###-#### final ok
|
GCE11-00081
| GCE-Final | 9/12/2011 | 9/13/2011 | 9/13/2011 8:45:50 AM | A | PASS |
|
|
Toby @ ###-#### final ok
|
GCE11-00067
| GCE-Final | 9/12/2011 | 9/13/2011 | 9/13/2011 8:15:01 AM | A | PASS |
|
|
Terry @ ###-#### low voltage puck lighting final ok
|