Inspections for the day of: Thursday, September 13, 2018.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-03396 Rough-in9/12/20189/13/20189/13/2018 4:11:55 PMPPART
Please call Aaron with any questions. Thanks! Phone #: ###-#### Inspection requested via web by john shay
- supply runs ok- dryer vent ok- range hood vent ok- 20lb gas pressure test ok- new flex gas line to range needs an approved termination plate at wall behind range-5lb flue pressure test ok need to see another 5lb test when finished tieing in venting to furnaces- exhaust fan upstairs not finished and I counted more than 3 bath fans need to add two more fans to permit
MEC18-04443 Final9/12/20189/13/20189/13/2018 4:00:45 PMPPASS
PLEASE CALL OUR LEAD INSTALLER BRAD WHEN 30 MINS IN ROUTE. IF POSSIBLE WE WOULD LIKE LATER AFTERNOON APPT 2-4P SO WE CAN HAVE FLUE PRESSURED AND READY WHEN YOU COME.
THANKS Phone #: ###-#### Inspection requested via web by Rick Montgomery
- furnace only co ok- 5lb flue pressure test ok
MEC18-04457 Final9/12/20189/13/20189/13/2018 3:11:35 PMPFAIL
can you please call when you are on the way. Customers name is Maryann and her # is ###-#### Phone #: ###-#### Inspection requested via web by Marisa Hone- furnace ac coil co ok- failed need to add other for duct work installed- once added to permit and fees paid reschedule inspection
MEC18-04406 Final9/10/20189/13/20189/13/2018 2:49:50 PMPFAIL
Please call Bill at ###-#### when in route. Phone #: ###-#### Inspection requested via web by Sabrina DeHority- need to get the condensate line off the ground and turn a 90 elbow down to the ground
MEC18-04437 Final9/13/20189/13/20189/13/2018 2:03:31 PMPPASS
- duct work seal ok- registers secured to ceiling ok- final ok card not onsite
MEC18-04451 Final9/12/20189/13/20189/13/2018 1:39:57 PMPFAIL
Please call Homeowner Matt ###-#### when en-route. Thank you Phone #: ###-#### Inspection requested via web by Nick Drake- penetrations in exterior wall by A/C need sealed- gas line at furnace needs a drip leg installed- need to install co detectors by bedrooms- furnace flue needs 6" clearances from duct insulation or needs b vent installed with a 1" clearances to insulation
MEC18-04409 Pressure Test9/10/20189/13/20189/13/2018 1:11:48 PMPPASS
INSTALLER ANAS ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- 60lb gas pressure test ok
MEC18-04438 Rough-in9/12/20189/13/20189/13/2018 10:59:05 AMAPASS
Phone #: ###-#### Inspection requested via web by Frank Marturello - R/I ok
MEC18-04438 Pressure Test9/12/20189/13/20189/13/2018 10:58:33 AMAPASS
Shaun: ###-#### Phone #: ###-#### Inspection requested via web by Frank Marturello
- 20lb gas pressure test ok- 5lb flue pressure test ok
MEC18-02141 Final9/12/20189/13/20189/13/2018 9:55:26 AMAPASS
NO GAS OR POWER AT TRIM, METER LOCKED
BRETT ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace final ok- gas meter is not locked anymore
MEC18-04437 Final9/12/20189/13/20189/13/2018 9:24:10 AMAFAIL
Phone #: ###-#### Inspection requested via web by Raul Castanon- need to seal duct work and need to screw grilles to ceiling grid- I rescheduled this inspection for this afternoon contractor is going to fix corrections
MEC17-05603 Mec-Aging Inspection9/13/20189/13/20189/13/2018 8:46:13 AM CANC
permit still in a HOLD
MEC18-04452 Final9/12/20189/13/20189/12/2018 2:39:36 PMPCANC
Please call Craig when on way at ###-#### Phone #: ###-#### >> Inspection requested via web by Krista Boss Inspection cancelled from web by: Krista Boss