MEC18-03396
| Rough-in | 9/12/2018 | 9/13/2018 | 9/13/2018 4:11:55 PM | P | PART |
|
|
Please call Aaron with any questions. Thanks! Phone #: ###-#### Inspection requested via web by john shay - supply runs ok- dryer vent ok- range hood vent ok- 20lb gas pressure test ok- new flex gas line to range needs an approved termination plate at wall behind range-5lb flue pressure test ok need to see another 5lb test when finished tieing in venting to furnaces- exhaust fan upstairs not finished and I counted more than 3 bath fans need to add two more fans to permit
|
MEC18-04443
| Final | 9/12/2018 | 9/13/2018 | 9/13/2018 4:00:45 PM | P | PASS |
|
|
PLEASE CALL OUR LEAD INSTALLER BRAD WHEN 30 MINS IN ROUTE. IF POSSIBLE WE WOULD LIKE LATER AFTERNOON APPT 2-4P SO WE CAN HAVE FLUE PRESSURED AND READY WHEN YOU COME. THANKS Phone #: ###-#### Inspection requested via web by Rick Montgomery - furnace only co ok- 5lb flue pressure test ok
|
MEC18-04457
| Final | 9/12/2018 | 9/13/2018 | 9/13/2018 3:11:35 PM | P | FAIL |
|
|
can you please call when you are on the way. Customers name is Maryann and her # is ###-#### Phone #: ###-#### Inspection requested via web by Marisa Hone- furnace ac coil co ok- failed need to add other for duct work installed- once added to permit and fees paid reschedule inspection
|
MEC18-04406
| Final | 9/10/2018 | 9/13/2018 | 9/13/2018 2:49:50 PM | P | FAIL |
|
|
Please call Bill at ###-#### when in route. Phone #: ###-#### Inspection requested via web by Sabrina DeHority- need to get the condensate line off the ground and turn a 90 elbow down to the ground
|
MEC18-04437
| Final | 9/13/2018 | 9/13/2018 | 9/13/2018 2:03:31 PM | P | PASS |
|
|
- duct work seal ok- registers secured to ceiling ok- final ok card not onsite
|
MEC18-04451
| Final | 9/12/2018 | 9/13/2018 | 9/13/2018 1:39:57 PM | P | FAIL |
|
|
Please call Homeowner Matt ###-#### when en-route. Thank you Phone #: ###-#### Inspection requested via web by Nick Drake- penetrations in exterior wall by A/C need sealed- gas line at furnace needs a drip leg installed- need to install co detectors by bedrooms- furnace flue needs 6" clearances from duct insulation or needs b vent installed with a 1" clearances to insulation
|
MEC18-04409
| Pressure Test | 9/10/2018 | 9/13/2018 | 9/13/2018 1:11:48 PM | P | PASS |
|
|
INSTALLER ANAS ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- 60lb gas pressure test ok
|
MEC18-04438
| Rough-in | 9/12/2018 | 9/13/2018 | 9/13/2018 10:59:05 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Frank Marturello - R/I ok
|
MEC18-04438
| Pressure Test | 9/12/2018 | 9/13/2018 | 9/13/2018 10:58:33 AM | A | PASS |
|
|
Shaun: ###-#### Phone #: ###-#### Inspection requested via web by Frank Marturello - 20lb gas pressure test ok- 5lb flue pressure test ok
|
MEC18-02141
| Final | 9/12/2018 | 9/13/2018 | 9/13/2018 9:55:26 AM | A | PASS |
|
|
NO GAS OR POWER AT TRIM, METER LOCKED BRETT ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace final ok- gas meter is not locked anymore
|
MEC18-04437
| Final | 9/12/2018 | 9/13/2018 | 9/13/2018 9:24:10 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Raul Castanon- need to seal duct work and need to screw grilles to ceiling grid- I rescheduled this inspection for this afternoon contractor is going to fix corrections
|
MEC17-05603
| Mec-Aging Inspection | 9/13/2018 | 9/13/2018 | 9/13/2018 8:46:13 AM | | CANC |
|
|
permit still in a HOLD
|
MEC18-04452
| Final | 9/12/2018 | 9/13/2018 | 9/12/2018 2:39:36 PM | P | CANC |
|
|
Please call Craig when on way at ###-#### Phone #: ###-#### >> Inspection requested via web by Krista Boss Inspection cancelled from web by: Krista Boss
|