Inspections for the day of: Wednesday, September 14, 2005.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-01612 ELE-Aging Inspection9/14/20059/14/20059/15/2005 8:48:23 AM PART
WSUC
ELE05-03216 Temporary Service9/14/20059/14/20059/14/2005 4:48:22 PMPPASS
Scheduled by a contractor via Hello! on 9/14/2005 at 9:30:59 AM. Contact: ###-####. t/s u/g new ok
ELE05-03341 Permanent Service9/14/20059/14/20059/14/2005 4:11:39 PMPFAIL
all violations not corrected met with owner he needs to secure electrical contractor , all he wants to do is argue GEC conductors not nterminated to neutral bus, needs to ID neutral needs connectors for GEC, needs to install 2 grd rods he put bond bushings on PVC conduit
ELE05-01404 Electrical Rough-In9/14/20059/14/20059/14/2005 3:07:21 PMPPASS
eric///ceiling inspection please; Phone #: ###-#### Internet Inspection Request from: Barbara Moore all grid ceilings ok
ELE05-02960 Electrical Rough-In9/13/20059/14/20059/14/2005 2:17:51 PMPPART
dan Note: ceiling roughin; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles grid ceilings ok
ELE05-01286 ELE-Aging Inspection9/14/20059/14/20059/14/2005 1:16:59 PM FAIL
no access to sign called could not get hold of anyone for information
ELE05-02951 Final9/13/20059/14/20059/14/2005 1:04:15 PMAFAIL
charlene; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles cor. posted called 314.16 box fill, 314.17 needs connectors where romex enters 1/2 KOs, 250.148 shall terminate all equip grds together in boxes, shall IDwhite wire in 10/2 for WH needs light fixtue or switched outlet for liv rm
ELE05-01675 ELE-Aging Inspection9/14/20059/14/20059/14/2005 12:50:26 PM PART
no response from contractor
ELE05-03356 Temporary Service9/14/20059/14/20059/14/2005 12:45:37 PMPPASS
Scheduled by a contractor via Hello! on 9/14/2005 at 8:33:06 AM. Contact: ###-####. t/s u/g new ok
ELE05-03320 Electrical Rough-In9/14/20059/14/20059/14/2005 12:06:12 PMPPART
tom ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie still needs p/s calculation and inspection for wiring in attic space, also inspection for p/s
ELE05-03346 Rough-In Permanent Service9/13/20059/14/20059/14/2005 10:57:09 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Joe Thomas r/i ok
p/s u/g new ok
ELE05-02117 Final9/14/20059/14/20059/14/2005 9:49:52 AMAPASS
Scheduled by a contractor via Hello! on 9/14/2005 at 6:39:28 AM. Contact: ###-####. ok card signed
ELE05-03003 Final9/12/20059/14/20059/14/2005 8:53:26 AMACANC
wire in folder machine - 30 amp 3-phase circuit. someone is there during the day.; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell
ELE05-03171 Final9/12/20059/14/20059/14/2005 8:42:08 AMAPASS
customer is at home in the mornings; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell motion light ok
ELE05-03003 DOC - Permit Finaled9/14/20059/14/20059/14/2005 12:00:00 AMPPASS
wire in folder machine - 30 amp 3-phase circuit. someone is there during the day.; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell no work done at address owner said it is in meridian