ELE05-01612
| ELE-Aging Inspection | 9/14/2005 | 9/14/2005 | 9/15/2005 8:48:23 AM | | PART |
|
|
WSUC
|
ELE05-03216
| Temporary Service | 9/14/2005 | 9/14/2005 | 9/14/2005 4:48:22 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 9/14/2005 at 9:30:59 AM. Contact: ###-####. t/s u/g new ok
|
ELE05-03341
| Permanent Service | 9/14/2005 | 9/14/2005 | 9/14/2005 4:11:39 PM | P | FAIL |
|
|
all violations not corrected met with owner he needs to secure electrical contractor , all he wants to do is argue GEC conductors not nterminated to neutral bus, needs to ID neutral needs connectors for GEC, needs to install 2 grd rods he put bond bushings on PVC conduit
|
ELE05-01404
| Electrical Rough-In | 9/14/2005 | 9/14/2005 | 9/14/2005 3:07:21 PM | P | PASS |
|
|
eric///ceiling inspection please; Phone #: ###-#### Internet Inspection Request from: Barbara Moore all grid ceilings ok
|
ELE05-02960
| Electrical Rough-In | 9/13/2005 | 9/14/2005 | 9/14/2005 2:17:51 PM | P | PART |
|
|
dan Note: ceiling roughin; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles grid ceilings ok
|
ELE05-01286
| ELE-Aging Inspection | 9/14/2005 | 9/14/2005 | 9/14/2005 1:16:59 PM | | FAIL |
|
|
no access to sign called could not get hold of anyone for information
|
ELE05-02951
| Final | 9/13/2005 | 9/14/2005 | 9/14/2005 1:04:15 PM | A | FAIL |
|
|
charlene; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles cor. posted called 314.16 box fill, 314.17 needs connectors where romex enters 1/2 KOs, 250.148 shall terminate all equip grds together in boxes, shall IDwhite wire in 10/2 for WH needs light fixtue or switched outlet for liv rm
|
ELE05-01675
| ELE-Aging Inspection | 9/14/2005 | 9/14/2005 | 9/14/2005 12:50:26 PM | | PART |
|
|
no response from contractor
|
ELE05-03356
| Temporary Service | 9/14/2005 | 9/14/2005 | 9/14/2005 12:45:37 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 9/14/2005 at 8:33:06 AM. Contact: ###-####. t/s u/g new ok
|
ELE05-03320
| Electrical Rough-In | 9/14/2005 | 9/14/2005 | 9/14/2005 12:06:12 PM | P | PART |
|
|
tom ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie still needs p/s calculation and inspection for wiring in attic space, also inspection for p/s
|
ELE05-03346
| Rough-In Permanent Service | 9/13/2005 | 9/14/2005 | 9/14/2005 10:57:09 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Joe Thomas r/i ok p/s u/g new ok
|
ELE05-02117
| Final | 9/14/2005 | 9/14/2005 | 9/14/2005 9:49:52 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 9/14/2005 at 6:39:28 AM. Contact: ###-####. ok card signed
|
ELE05-03003
| Final | 9/12/2005 | 9/14/2005 | 9/14/2005 8:53:26 AM | A | CANC |
|
|
wire in folder machine - 30 amp 3-phase circuit. someone is there during the day.; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell
|
ELE05-03171
| Final | 9/12/2005 | 9/14/2005 | 9/14/2005 8:42:08 AM | A | PASS |
|
|
customer is at home in the mornings; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell motion light ok
|
ELE05-03003
| DOC - Permit Finaled | 9/14/2005 | 9/14/2005 | 9/14/2005 12:00:00 AM | P | PASS |
|
|
wire in folder machine - 30 amp 3-phase circuit. someone is there during the day.; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell no work done at address owner said it is in meridian
|