Inspections for the day of: Thursday, September 14, 2006.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-03277 Permanent Service9/14/20069/14/20069/14/2006 4:47:07 PMPCANC
My cell phne # is ###-#### if you have any questions. Thanks, Randy; Phone #: ###-#### Internet Inspection Request from: Randy Fletcher wrong address needs sealing locknut top of p/s and ID white wire in romex used for 220v circuits different color called
ELE05-04071 Final9/13/20069/14/20069/14/2006 4:16:42 PMAPART
###-#### temp occupancy ok card signed
ELE06-03432 Rough-In Permanent Service9/14/20069/14/20069/14/2006 4:16:08 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Shaun Kirkman r/i p/s u/g new ok all 4 units
ELE06-03439 Conference9/14/20069/14/20069/14/2006 4:15:37 PMPCANC
stu; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called contr wanted me to tell him how to wire house
ELE06-03403 Rough-In Permanent Service9/14/20069/14/20069/14/2006 2:10:41 PMPCANC
Scheduled by a contractor via Hello! on 9/14/2006 at 7:46:33 AM. Contact: ###-####. contr called in wrong permit number called
ELE06-03413 Electrical Rough-In9/14/20069/14/20069/14/2006 2:06:43 PMPPART
PAUL UNDERGROUND INSPECTION; Phone #: ###-#### Internet Inspection Request from: Sean DeLacy ok
ELE06-03397 Permanent Service9/14/20069/14/20069/14/2006 12:56:28 PMPFAIL
Seth; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt corr. 250.52(A)(1) or 104(A)(1) grd or bond water system at service not subpanel, 250.53 grd rods shall be 6ft apart, 110.12(A) seal all KOs, conn. for GEC, install backfeed clip
ELE06-01022 Final9/14/20069/14/20069/14/2006 12:03:30 PMPFAIL
jeff; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley needs gfci for all SABC
ELE06-03431 Permanent Service9/13/20069/14/20069/14/2006 10:21:02 AMAPASS
shawn; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
p/s u/g new ok
ELE06-03430 Permanent Service9/13/20069/14/20069/14/2006 10:20:28 AMAPASS
shawn; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
p/s u/g new ok
ELE06-03358 Temporary Service9/13/20069/14/20069/14/2006 8:20:40 AMAPASS
glen; Phone #: ###-#### Internet Inspection Request from: Cathy Chile t/s o/h new ok
ELE06-03432 Rough-In Permanent Service9/13/20069/14/20069/14/2006 7:58:05 AMANR
Jack please call me before you come to inspect I have a couple of questions Internet Inspection Request from: Shaun Kirkman called