PDS Online
Making
Boise
the most livable city in the country.
Home
Permits
Search by Permit Number
How to search by permit number
Search by Address
Search by Customer Number
Search by Current Planning Number
Search in Project by Permit Number
Search by Project Name
Inspections
Search by Permit Number
Search by Request Date
Search by Company Name
Fees
Impact Fees Estimate Calculator
Other Searches
Search for Licensed Contractors
Search Parcel by Address
Search Historical Surveys
Reports
Daily Reports
Weekly Reports
Monthly Reports
Home
/
Inspections
/
Inspector Activity
Inspections for the day of:
Monday, September 14, 2009
.
Number of inspections:
7
Percentage of inspections complete:
86 %
Percentage of inspections not complete:
14 %
Contact Information
Inspector
Clint A Smith
Title
EROSION CONTROL INSPECTOR
Phone #
794-8996
Permit Number
Description
Received
Requested
Completed
AM/PM
Disposition
ESC09-00501
Site Preparation
9/7/2009
9/7/2009
ESC07-00757
Aging Inspection
9/14/2009
9/14/2009
9/15/2009 3:50:48 PM
PASS
ESC09-00404
Site Preparation
9/11/2009
9/14/2009
9/14/2009 4:10:16 PM
A
FAIL
Verbal message via phone and e-mail:
1. Extend the construction exit to the south at least a min. of 50ft.
2. Stabilize of block off access point to the north.
3. Install silt fence per manufactures specifications. (Pocket silt fence must have ths stakes on the inside of what you are trying to stop from siltation).
4. Extend sediment barrier to protect the south for total protection of the canal. (Gap between silt fence and the wattle.)
Must be completed by 9/17/09PM. Will re-inspect on 9/18/09AM.
ESC09-00507
Site Preparation
9/14/2009
9/14/2009
9/14/2009 3:13:18 PM
P
FAIL
Given to RP:
Correction Notice:
1. Install sediment barriers along the North east and south east side of disturbed areas.
2.At or prior to the end of the day, excavate out sediment traps along the slope of depths of at least 2-4ft deep.
3. At the bottom of slope recommend using pastic sheeting over the slope of the last swale of the west side of the slope. Make sure it is keyed in at the back of slope and weighed down.
Will re-inspect on 9/15/09 Pm.
ESC08-00457
Tracking Control
9/10/2009
9/14/2009
9/14/2009 9:44:39 AM
A
PART
Verbal to RP:
Prior to any activity when utilizing the exit onto Overland road, a top dressing is required of 2 inch or great of some type of washed rock. Also include street sweeping and a laborer to clean up any tracking of any material at the time that it occurs. Will follow up with isssue on 10/01/09 AM.
ESC08-00480
General Inspection
9/14/2009
9/14/2009
9/14/2009 9:01:05 AM
PASS
ESC08-00585
General Inspection
9/14/2009
9/14/2009
9/14/2009 8:53:12 AM
PASS
No activity bu t all permits still open.