Inspections for the day of: Monday, September 14, 2015.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-02909 Electrical Rough-In9/11/20159/14/20159/14/2015 3:01:17 PMPCANC
We are requesting a wall rough-in inspection for Monday 9/14/15 in the afternoon. Our onsite contact is Rich ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate Building permit has not been purchaced yet contractor will reschedule when building permit exists.
ELE15-02925 Permanent Service9/14/20159/14/20159/14/2015 2:59:43 PMPCANC
Idaho Power could not get out until 10:00am, we are upgrading the service, please call the office before you head over to make sure the technicians are ready. Thank You. Phone #: ###-#### >> Inspection requested via web by Clay Morgan Inspection cancelled from web by: Clay Morgan
ELE15-00796 Final9/14/20159/14/20159/14/2015 2:57:08 PMPPASS
We are requesting a final inspection for today 9/14/15 this afternoon. Our onsite contact is Rich @ ###-####. Thank you,
Phone #: ###-#### Inspection requested via web by Clint Tate Charging stations off building 1 and 4 Final ok
ELE15-02428 Electrical Rough-In9/14/20159/14/20159/14/2015 2:10:45 PMPPASS
underground; Alan Phone #: ###-#### Underground to green house rough in ok cover
ELE15-02923 Temporary Service9/14/20159/14/20159/14/2015 1:49:58 PMPPASS
Phone #: ###-#### Inspection requested via web by Robert Schroder t/s u/g n ok
ELE15-02922 Electrical Rough-In9/14/20159/14/20159/14/2015 1:48:09 PMPFAIL
Complete residential home wiring. Contact Tom Betty @ ###-#### Phone #: ###-#### Inspection requested via web by Cathy Duchek 110.3- Expansion joint in service riser shall be installed to manufacturers instructions. Shall be installed to allow movement in both directions. 210.52(G)(1)- At least 1 receptacle outlet shall be installed for each car bay. These receptacle outlets shall not feed outlets outside garage. 334.12- Check 12-2 NM cable, maybe installed where subfect to physical damage. Down hall under drywall nailer. Upstairs bed driven into staple under cable maybe damaged. 334.80- Where multiple NM cables pass through bored holes with out maintaining spacing allowable ampacity shall be adjusted. Above garage warm wall 12 and 10 current carrying conductors.
ELE15-02502 Final9/13/20159/14/20159/14/2015 10:08:33 AMAFAIL
Dan ###-#### Inspection requested via web by Dan Hobdey 422.30- A means shall be provided to disconnect each appliance from all ungrounded conductors. Micro, oven, cooktop, dishwasher. 408.4- Circuit directory shall legibly identfiy each circuit as to its clear, evident, and specific purpose
ELE15-02354 Final9/13/20159/14/20159/14/2015 9:43:45 AMAPASS
Dan Phone #: ###-#### Inspection requested via web by Dan Hobdey Service final ok
ELE15-02745 Final9/14/20159/14/20159/14/2015 9:15:07 AMAPASS
Phone #: ###-#### Inspection requested via web by Eddy Udry Final ok
ELE15-02696 Electrical Rough-In9/11/20159/14/20159/14/2015 9:01:53 AMAPASS
Bob Thomas Phone #: ###-#### Inspection requested via web by Kerri Hamilton Grid rough in ok cover
ELE15-02695 Electrical Rough-In9/11/20159/14/20159/14/2015 9:01:04 AMAPASS
Bob Thomas Phone #: ###-#### Inspection requested via web by Kerri Hamilton Grid rough in ok cover
ELE14-03133 Final9/11/20159/14/20159/14/2015 12:00:00 AMPCANC
Brad Phone #: ###-####-please call 15 minutes prior for access
ELE15-01111 Electrical Rough-In9/9/20159/14/20159/11/2015 10:19:58 AMPCANC
We need a wall cover inspection for afternoon. Site contact is Mike Poff Phone #: ###-#### >> Inspection requested via web by Stacie Tasker Inspection cancelled from web by: Stacie Tasker