ELE06-03454
| Electrical Rough-In | 9/15/2006 | 9/15/2006 | 9/15/2006 4:35:26 PM | P | FAIL |
|
|
cal - call prior for access; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley called, left corr notice, nec 210.52(A)(1) recpts shall be installed in mud room and top of stairs for 6'-12' spacing, 210.52(E) at least 1 recpt shall be at back of dwelling, 210.52(D) recpt shall be installed within 3' of each basin in bath, 210.11(C)(3) bath circuits shall be dedicated 20a branch circuits, 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing member, or covered with steel plates, 250.86 metal enclosure in hall for light shall be grounded, 210.12(B) bedrooms shall be afci protected, BCC all make-up shall be done, smoke detectors shall be installed in required areas, no violations shall be retained Note, later told contr that if no work done in room recpt would not have to be installed (bath)
|
ELE06-02921
| Electrical Rough-In | 9/15/2006 | 9/15/2006 | 9/15/2006 4:15:37 PM | P | NR |
|
|
mike Note: ceiling; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles met contr, left corr notice, fee due, nec 300.11 (A) support wires shall be secured at both ends, 330.30(A) cable shall be secured within12" of termination and not over 6', BCC work shall be ready for inspection and no remaining work to follow inspection
|
ELE06-02416
| Electrical Rough-In | 9/15/2006 | 9/15/2006 | 9/15/2006 3:18:10 PM | P | PASS |
|
|
ceiling inspection for Lees candies; Phone #: ###-#### Internet Inspection Request from: Jim Williams clg ok to cover, signed green card for part final and t/o, bldr not ready to sign regular t/o card, they will put in tunnel for customer access
|
ELE06-02555
| Final | 9/15/2006 | 9/15/2006 | 9/15/2006 2:55:38 PM | P | PASS |
|
|
joe; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called, left survey, nec 210.63 125v recpt shall be within 25' of ac for servicing,404.9(A) sw plate shall seat against finished surface, ok to final
|
ELE06-02057
| Final | 9/14/2006 | 9/15/2006 | 9/15/2006 12:18:39 PM | A | PASS |
|
|
WE ARE READY FOR FINAL INSPECTION OF THE THEATER ROOM. THERE WILL BE AN EMPLOYEE OF THE STORE THERE ANY TIME AFTER 9:00 AM. BREN WOULD BE THE BEST CONTACT AT THE STORE AND IF YOU HAVE ANY OTHER QUESTIONS, PLEASE FEEL FREE TO CONTACT BRIAN KEITH AT THE OFFICE AT ###-####. THANK YOU.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH ok to final
|
ELE06-02712
| Final | 9/14/2006 | 9/15/2006 | 9/15/2006 11:56:15 AM | A | PASS |
|
|
Daryl; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt called contr about outside recpts, ok to final
|
ELE06-03444
| Permanent Service | 9/14/2006 | 9/15/2006 | 9/15/2006 9:58:16 AM | A | NR |
|
|
robert ; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley called contr, left corr notice, BCC no address, no job id sticker,no power or inspection shall be done without above
|
ELE06-02497
| Final | 9/15/2006 | 9/15/2006 | 9/15/2006 9:43:11 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 9/15/2006 at 7:01:12 AM. Contact: ###-####. ok to final
|
ELE06-03281
| Electrical Rough-In | 9/14/2006 | 9/15/2006 | 9/15/2006 9:34:13 AM | P | CANC |
|
|
Please inspect partial B-wing underground in PM. Thanks; Phone #: ###-#### Internet Inspection Request from: Jim Friend Inspection cancelled from web by: Jim Friend
|
ELE06-02613
| Electrical Rough-In | 9/14/2006 | 9/15/2006 | 9/15/2006 9:02:56 AM | A | PART |
|
|
this is for a ceiling inspection, any questions please call James Lingelbaugh; Phone #: ###-#### Internet Inspection Request from: Jeff Radford ok to cover 6 office clgs only, 1st fl, left corr notice about rest of fixtures, nec 400.8 flexible cord and cables shall not be used as a substitue for the fixed wiring of a structure, talked to contr
|
ELE06-02309
| Final | 9/14/2006 | 9/15/2006 | 9/15/2006 8:45:38 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Sean DeLacy ok to final
|
ELE06-02750
| Final | 9/15/2006 | 9/15/2006 | 9/15/2006 12:00:00 AM | P | CANC |
|
|
joe; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles per joe cancelled
|