PLM15-00158
| PLM-Aging Inspection | 9/15/2015 | 9/15/2015 | 9/16/2015 1:59:05 PM | | PASS |
|
|
|
PLM15-02365
| Water and/or Sewer | 9/15/2015 | 9/15/2015 | 9/15/2015 4:21:00 PM | P | PEND |
|
|
Phone #: ###-#### Inspection requested via web by Brent Lacy >waiting on material specs
|
PLM15-03156
| Water and/or Sewer | 9/15/2015 | 9/15/2015 | 9/15/2015 3:58:09 PM | P | PASS |
|
|
|
PLM15-03140
| Other | 9/14/2015 | 9/15/2015 | 9/15/2015 3:08:19 PM | P | FAIL |
|
|
Pressure test Phone #: ###-#### Inspection requested via web by Raul Castanon >pressure test failed @ 54psi
|
PLM15-02821
| Plumbing Rough-in | 9/15/2015 | 9/15/2015 | 9/15/2015 2:29:53 PM | P | FAIL |
|
|
STEVE RADY, CONTRACTOR, ###-#### Phone #: ###-#### Inspection requested via web by Chris Field >1 Need permanent glue caps on demoed plumbing. >2 Santee not approved for horizontal use @ wb >3 must be 6" above flood level rim before turning horizontal @ mop sink upc 905.3 >4 leak at nipple on hot side of wh loop. >5 retest and re inspect
|
PLM15-03009
| Groundwork | 9/15/2015 | 9/15/2015 | 9/15/2015 1:52:56 PM | P | FAIL |
|
|
Bill Phone #: ###-#### >1 DWV leak at 3x2 wye for shower, cut out and replace per 310.2 upc, unlawful to conceal hole with solvent cement. >2 3" pipe at 22 does not enter hub square, redo >3" drain is backgraded at santee for wc. >4 2" shower drain needs 1/4" per ft grade >5 make repairs and retest dwv
|
PLM15-01410
| Final | 9/14/2015 | 9/15/2015 | 9/15/2015 1:28:20 PM | P | NR |
|
|
MATT IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER
|
PLM15-03157
| Sprinkler (Final) | 9/15/2015 | 9/15/2015 | 9/15/2015 1:06:41 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darrell Roark
|
MIS15-00239
| PLM-Final | 9/14/2015 | 9/15/2015 | 9/15/2015 11:33:40 AM | A | PART |
|
|
>need to seperate rp feeding coke and coffee and add additional rp to coffee >permit new rp that was installed for coke. >building premise protection needs certified.
|
PLM14-03013
| Final | 9/14/2015 | 9/15/2015 | 9/15/2015 10:39:49 AM | A | PASS |
|
|
Home owner will be home and ready by 9 am. Thanks Troy Phone #: ###-#### Inspection requested via web by Troy Paulin
|
PLM15-02482
| Final | 9/14/2015 | 9/15/2015 | 9/15/2015 10:21:55 AM | A | FAIL |
|
|
Home owners will be home. Thanks you Troy Phone #: ###-#### Inspection requested via web by Troy Paulin >need min 1" airgap at softener drain in washer box
|
PLM15-01723
| Water and/or Sewer | 9/15/2015 | 9/15/2015 | 9/15/2015 9:56:39 AM | A | PART |
|
|
Talk to Bill Vandergriff regarding sample ports. they are not needed Phone #: ###-#### Inspection requested via web by Raul Castanon >incp venting ok >incp inlet and outlet ok >incp 24 test ok
|
PLM15-03142
| Plumbing Rough-in | 9/14/2015 | 9/15/2015 | 9/15/2015 9:30:36 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Tom Maxwell
|
PLM15-03156
| Water and/or Sewer | 9/15/2015 | 9/15/2015 | 9/15/2015 9:14:19 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Brett Simmons >unsuitable material around waterline, need 6" below water line with no rocks.
|
PLM15-03099
| Water Heater Final | 9/9/2015 | 9/15/2015 | 9/14/2015 3:01:39 PM | A | CANC |
|
|
water heater final - Homeowner request am inspection. Please call Brian Neibaur when en route at ###-####. Thank you! Phone #: ###-#### >> Inspection requested via web by TERRY SIDWELL Inspection cancelled from web by: TERRY SIDWELL
|