BLD15-00669
| BLD-Ceiling Grid Inspection | 9/15/2015 | 9/15/2015 | 9/15/2015 4:42:14 PM | P | CANC |
|
|
Kevin// the later the better Phone #: ###-####
|
BLD15-03237
| BLD-Final | 9/14/2015 | 9/15/2015 | 9/15/2015 4:18:39 PM | P | FAIL |
|
|
Please call 30min for access - Manuel Phone #: ###-####. Provide key locking hardware at main exit, provide lever type hardware at new shop door and additional exit. remove all deadbolts and associated hardware. patch sheetrock to maintain 1hr. seperation. repair broken light fixture in janitors closet.
|
BLD14-03300
| BLD-Other | 9/15/2015 | 9/15/2015 | 9/15/2015 3:54:54 PM | P | PASS |
|
|
Sheet rock // Rocko Phone #: ###-####
|
BLD13-03601
| BLD-Final | 9/15/2015 | 9/15/2015 | 9/15/2015 3:54:28 PM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Tyler Hildebrand
|
BLD15-00492
| BLD-Final | 9/15/2015 | 9/15/2015 | 9/15/2015 3:45:56 PM | P | PASS |
|
|
Jeremy Phone #: ###-####. Ok for perm occ.
|
BLD15-00669
| BLD-Other | 9/15/2015 | 9/15/2015 | 9/15/2015 3:29:34 PM | P | PART |
|
|
Kevin// the later the better Phone #: ###-####. Work in progress for welded wire mesh at slab on grade, pend. special inspection.
|
BLD15-00240
| BLD-Foundation | 9/14/2015 | 9/15/2015 | 9/15/2015 3:28:19 PM | P | PASS |
|
|
John Phone #: ###-####
|
BLD15-03269
| BLD-Footing | 9/15/2015 | 9/15/2015 | 9/15/2015 2:59:21 PM | P | PASS |
|
|
|
BLD13-03601
| BLD-Final | 9/15/2015 | 9/15/2015 | 9/15/2015 2:36:30 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Tyler Hildebrand. ok for temp occ. Will be ok for perm occ. once zoning and signs perm.
|
BLD15-02055
| BLD-Footing | 9/14/2015 | 9/15/2015 | 9/15/2015 2:34:57 PM | P | NR |
|
|
Dane Phone #: ###-####. No one on site, no concrete forms built or on site.
|
GCB15-00123
| GCB-Energy | 9/14/2015 | 9/15/2015 | 9/15/2015 2:28:00 PM | P | PASS |
|
|
Steve ###-#### - front door unlocked *DO NOT RING DOORBELL* - requests insp. after 2p.m.
|
BLD15-02105
| BLD-Energy code compliance | 9/15/2015 | 9/15/2015 | 9/15/2015 2:27:21 PM | P | PASS |
|
|
Robert Phone #: ###-####
|
BLD15-01424
| BLD-Final | 9/15/2015 | 9/15/2015 | 9/15/2015 2:26:53 PM | P | PASS |
|
|
Colby Phone #: ###-####
|
BLD15-01424
| DOC - Permit Finaled | 9/15/2015 | 9/15/2015 | 9/15/2015 2:26:35 PM | P | PASS |
|
|
|
BLD15-02471
| BLD-Energy code compliance | 9/15/2015 | 9/15/2015 | 9/15/2015 2:26:06 PM | P | PASS |
|
|
Tom Phone #: ###-####
|
BLD15-02362
| BLD-Framing/Rough-in | 9/15/2015 | 9/15/2015 | 9/15/2015 2:25:07 PM | P | FAIL |
|
|
Tom// please call prior Phone #: ###-####. Fire block barrell vault, Seal abs pipe penetrations at top plates. Nail off simpson hangars on T26 trusses, Nail the 2 ply t03,t06 and tg01 per the truss engineering. ok to insulate, correction notice posted.
|
BLD15-02207
| BLD-Wall Bracing | 9/14/2015 | 9/15/2015 | 9/15/2015 12:01:45 PM | A | PASS |
|
|
Coco Phone #: ###-####
|
BLD15-01496
| BLD-Energy code compliance | 9/14/2015 | 9/15/2015 | 9/15/2015 11:38:40 AM | A | PASS |
|
|
Colby Phone #: ###-####
|
GCB15-00123
| GCB-Framing | 9/14/2015 | 9/15/2015 | 9/15/2015 11:23:43 AM | A | PASS |
|
|
Steve ###-#### - front door unlocked *DO NOT RING DOORBELL*
|
GCB15-00015
| GCB-Final | 9/14/2015 | 9/15/2015 | 9/15/2015 11:04:01 AM | A | PASS |
|
|
Dallas ###-#### - ADA sidewalk and Fishing Dock at Riverside Pond (Riverside and Glenwood). Accesible walk way to salvaged gangway ok.
|
BLD15-02357
| BLD-Framing/Rough-in | 9/15/2015 | 9/15/2015 | 9/15/2015 10:17:28 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Robert Snow. Interior steel stud wall in fitting room area ok.
|
BLD15-03269
| BLD-Footing | 9/14/2015 | 9/15/2015 | 9/15/2015 9:57:58 AM | A | NR |
|
|
Bill-please call with a meet time Phone #: ###-####. Moved to pm. inspection.
|
BLD15-02550
| BLD-Final | 9/14/2015 | 9/15/2015 | 9/15/2015 9:55:51 AM | A | PASS |
|
|
Tony Phone #: ###-####. Ok for perm occ.
|
ESC15-00925
| General Inspection | 9/15/2015 | 9/15/2015 | 9/15/2015 9:47:51 AM | A | PASS |
|
|
|
BLD15-02479
| BLD-Framing/Rough-in | 9/14/2015 | 9/15/2015 | 9/15/2015 9:41:32 AM | A | FAIL |
|
|
Joe Phone #: ###-####. Complete lateral bracing on T2,T6,T7 and T10 trusses. The interior bearing points on T6,T7,T8,T9 and T10 trusses have been missed. Provide fix from truss engineer.(Trusses backwards?) Foam all top plate penetrations at 1/2 inch gas line penetrations and at exterior wall. A mech permit and inspection is required for the gas fireplace prior to energy code inspection.
|
BLD13-03601
| BLD-Final | 9/14/2015 | 9/15/2015 | 9/15/2015 9:00:17 AM | A | NR |
|
|
Phone #: ###-#### Inspection requested via web by Tyler Hildebrand. Move to pm inspection.
|
BLD15-00278
| BLD-Framing/Rough-in | 9/14/2015 | 9/15/2015 | 9/14/2015 3:24:27 PM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Paul Thompson Inspection cancelled from web by: Paul Thompson
|
BLD15-00278
| BLD-Wall cover | 9/14/2015 | 9/15/2015 | 9/14/2015 9:06:04 AM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Paul Thompson Inspection cancelled from web by: Paul Thompson
|