Inspections for the day of: Friday, September 16, 2005.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-02806 Rough-In Permanent Service9/16/20059/16/20059/16/2005 4:25:30 PMPFAIL
Late afternoon if possible; Phone #: ###-#### Internet Inspection Request from: Ryan Christensen talked with contr, left corr notice, NEC 358.30(A) emt shall be secureley fastened within 3' of box, 330.30 mc cable shall be secured within 12" of box, 300.4(D) & (E) mc cable shall be min 1 1/4" from edge of framing member and if in groove protected by minimum 1/16" steel plate. raceways shall not be in c of channel,BCC all make-up shall be done, mud rings attached. Electrician shall get classification of NEC Art. 500.5 for locations using natural gas and oxygen.
ELE05-02250 Final9/16/20059/16/20059/16/2005 4:17:22 PMPPASS
dino; Phone #: ###-#### call for access code Internet Inspection Request from: Cathy Chiles corrections made, ok to final
ELE05-02268 Final9/16/20059/16/20059/16/2005 3:53:34 PMPPASS
###-#### - ron ok to final
ELE05-02914 Final9/16/20059/16/20059/16/2005 3:51:57 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Dana Moyer ok to final
ELE05-03035 Conference8/29/20059/16/20059/16/2005 1:50:35 PMPDONE
beverly at ###-#### office or home -###-#### talked about room add and elect
ELE05-03386 Electrical Rough-In9/16/20059/16/20059/16/2005 1:04:45 PMPCANC
Phone #: ###-#### Internet Inspection Request from: Clyde Logan see rip
ELE05-03021 Electrical Rough-In9/15/20059/16/20059/16/2005 12:14:45 PMAPASS
ceiling insp - olga; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie corr made, ok to cover ceiling only
ELE05-01869 Electrical Rough-In9/16/20059/16/20059/16/2005 9:50:14 AMAPASS
Soffit; Phone #: ###-#### Internet Inspection Request from: Jim Williams ok to cover soffits only
ELE05-00809 Final9/15/20059/16/20059/16/2005 9:42:38 AMAPASS
Scheduled by a contractor via Hello! on 9/15/2005 at 1:48:24 PM. Contact: ###-####. signed struct card, ok to final
ELE04-02203 Electrical Rough-In9/15/20059/16/20059/16/2005 8:39:17 AMACANC
Scheduled by a contractor via Hello! on 9/15/2005 at 7:50:07 AM. Contact: ###-####. nh, temp power pole permit, wrong phone no. in notes, bullet doesn't know about, should be expired
ELE05-03378 Temporary Service9/15/20059/16/20059/16/2005 8:20:37 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Nicole Richardson called contr, left corr notice, re-inspection fee due, BCC job id sticker shall be posted,address shall be posted, 250.52(A)(5) rod gnd electrode shall be 8' long,250.56 shall augment first rod with second gnd rod, 408.7 unused openings shall be closed, 312.5 abrasion protection shall be provided forconductors entering enclosure, 250.24(A)(1) gec shall terminate on same bus as grounded conductor
ELE05-03366 Final9/15/20059/16/20059/16/2005 8:10:09 AMACANC
Temp pole is in back corner of lot near house under construction. Internet Inspection Request from: Cevyn Recla see t/s
ELE05-03366 Temporary Service9/16/20059/16/20059/16/2005 12:00:00 AMAPASS
Temp pole is in back corner of lot near house under construction. Internet Inspection Request from: Cevyn Recla t/s u/g n ok
ELE05-03386 Rough-In Permanent Service9/16/20059/16/20059/16/2005 12:00:00 AMPPASS
Phone #: ###-#### Internet Inspection Request from: Clyde Logan ric ok, p/s u/g n ok