ELE05-02806
| Rough-In Permanent Service | 9/16/2005 | 9/16/2005 | 9/16/2005 4:25:30 PM | P | FAIL |
|
|
Late afternoon if possible; Phone #: ###-#### Internet Inspection Request from: Ryan Christensen talked with contr, left corr notice, NEC 358.30(A) emt shall be secureley fastened within 3' of box, 330.30 mc cable shall be secured within 12" of box, 300.4(D) & (E) mc cable shall be min 1 1/4" from edge of framing member and if in groove protected by minimum 1/16" steel plate. raceways shall not be in c of channel,BCC all make-up shall be done, mud rings attached. Electrician shall get classification of NEC Art. 500.5 for locations using natural gas and oxygen.
|
ELE05-02250
| Final | 9/16/2005 | 9/16/2005 | 9/16/2005 4:17:22 PM | P | PASS |
|
|
dino; Phone #: ###-#### call for access code Internet Inspection Request from: Cathy Chiles corrections made, ok to final
|
ELE05-02268
| Final | 9/16/2005 | 9/16/2005 | 9/16/2005 3:53:34 PM | P | PASS |
|
|
###-#### - ron ok to final
|
ELE05-02914
| Final | 9/16/2005 | 9/16/2005 | 9/16/2005 3:51:57 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Dana Moyer ok to final
|
ELE05-03035
| Conference | 8/29/2005 | 9/16/2005 | 9/16/2005 1:50:35 PM | P | DONE |
|
|
beverly at ###-#### office or home -###-#### talked about room add and elect
|
ELE05-03386
| Electrical Rough-In | 9/16/2005 | 9/16/2005 | 9/16/2005 1:04:45 PM | P | CANC |
|
|
Phone #: ###-#### Internet Inspection Request from: Clyde Logan see rip
|
ELE05-03021
| Electrical Rough-In | 9/15/2005 | 9/16/2005 | 9/16/2005 12:14:45 PM | A | PASS |
|
|
ceiling insp - olga; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie corr made, ok to cover ceiling only
|
ELE05-01869
| Electrical Rough-In | 9/16/2005 | 9/16/2005 | 9/16/2005 9:50:14 AM | A | PASS |
|
|
Soffit; Phone #: ###-#### Internet Inspection Request from: Jim Williams ok to cover soffits only
|
ELE05-00809
| Final | 9/15/2005 | 9/16/2005 | 9/16/2005 9:42:38 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 9/15/2005 at 1:48:24 PM. Contact: ###-####. signed struct card, ok to final
|
ELE04-02203
| Electrical Rough-In | 9/15/2005 | 9/16/2005 | 9/16/2005 8:39:17 AM | A | CANC |
|
|
Scheduled by a contractor via Hello! on 9/15/2005 at 7:50:07 AM. Contact: ###-####. nh, temp power pole permit, wrong phone no. in notes, bullet doesn't know about, should be expired
|
ELE05-03378
| Temporary Service | 9/15/2005 | 9/16/2005 | 9/16/2005 8:20:37 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Nicole Richardson called contr, left corr notice, re-inspection fee due, BCC job id sticker shall be posted,address shall be posted, 250.52(A)(5) rod gnd electrode shall be 8' long,250.56 shall augment first rod with second gnd rod, 408.7 unused openings shall be closed, 312.5 abrasion protection shall be provided forconductors entering enclosure, 250.24(A)(1) gec shall terminate on same bus as grounded conductor
|
ELE05-03366
| Final | 9/15/2005 | 9/16/2005 | 9/16/2005 8:10:09 AM | A | CANC |
|
|
Temp pole is in back corner of lot near house under construction. Internet Inspection Request from: Cevyn Recla see t/s
|
ELE05-03366
| Temporary Service | 9/16/2005 | 9/16/2005 | 9/16/2005 12:00:00 AM | A | PASS |
|
|
Temp pole is in back corner of lot near house under construction. Internet Inspection Request from: Cevyn Recla t/s u/g n ok
|
ELE05-03386
| Rough-In Permanent Service | 9/16/2005 | 9/16/2005 | 9/16/2005 12:00:00 AM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Clyde Logan ric ok, p/s u/g n ok
|