ELE11-01773
| Final | 9/16/2011 | 9/16/2011 | 9/16/2011 2:58:38 PM | P | PASS |
|
|
Please give me half an hour notice to insure access Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman ok final
|
ELE11-01718
| Final | 9/15/2011 | 9/16/2011 | 9/16/2011 2:57:57 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by steve sellers ok final
|
ELE11-02128
| Rough-In Permanent Service | 9/16/2011 | 9/16/2011 | 9/16/2011 2:56:28 PM | P | PASS |
|
|
>> Inspection requested via mobile web by Kevin corrections made, ri ok, p/s u/g n ok
|
ELE11-01547
| Final | 9/15/2011 | 9/16/2011 | 9/16/2011 2:11:57 PM | P | PASS |
|
|
Please Call Eli Dorsey at ###-#### and he will meet you there! Have a fantastic day! Phone #: ###-#### >> Inspection requested via web by Kevin Perez ok final, signed card
|
ELE11-01383
| Electrical Rough-In | 9/15/2011 | 9/16/2011 | 9/16/2011 1:22:38 PM | P | CANC |
|
|
ceiling inspection for cover. Phone #: ###-#### >> Inspection requested via web by steve sellers met contractor, called wrong day, wanted Monday
|
ELE11-01135
| Electrical Rough-In | 9/16/2011 | 9/16/2011 | 9/16/2011 12:47:33 PM | P | FAIL |
|
|
Ceiling inspection Phone #: ###-#### >> Inspection requested via web by Zane Robertson met contractor, shall remove all lv wiring not used per NEC 725.25
|
ELE11-01868
| Final | 9/16/2011 | 9/16/2011 | 9/16/2011 12:28:18 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson ok final
|
ELE11-02124
| Rough-In Permanent Service | 9/15/2011 | 9/16/2011 | 9/16/2011 11:55:21 AM | A | PASS |
|
|
New home Phone #: ###-#### >> Inspection requested via web by TOM BICAND ri ok, p/s u/g n okI
|
ELE11-01773
| Final | 9/16/2011 | 9/16/2011 | 9/16/2011 11:18:24 AM | P | CANC |
|
|
Please give me half an hour notice to insure access Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman Inspection cancelled from web by: Shaun Kirkman
|
ELE11-02127
| Permanent Service | 9/15/2011 | 9/16/2011 | 9/16/2011 10:43:45 AM | A | CANC |
|
|
Tony (or owner Paul ###-####) Phone #: ###-#### see conference
|
ELE11-02112
| Electrical Rough-In | 9/15/2011 | 9/16/2011 | 9/16/2011 10:32:03 AM | A | PASS |
|
|
Entry way addition rough Phone #: ###-#### >> Inspection requested via web by Barbara Szurgot ri ok
|
ELE11-01752
| Final | 9/15/2011 | 9/16/2011 | 9/16/2011 10:07:17 AM | A | FAIL |
|
|
Rocky or ###-#### Phone #: ###-#### called, NEC 110.16 shall provide workspace about equipment, close openings in panels, correct polarity for receptacle front window
|
ELE08-02423
| Final | 9/15/2011 | 9/16/2011 | 9/16/2011 9:46:21 AM | A | PART |
|
|
Building 3 Floors 1-4 Phone #: ###-#### >> Inspection requested via web by Sean DeLacy common and rooms part finalled, shall see after tenants make modifications, east side
|
ELE11-02127
| Conference | 9/16/2011 | 9/16/2011 | 9/16/2011 8:43:48 AM | A | DONE |
|
|
talked to owner about service, re-wiring parts of inside, must move service as it is about 12" from fence, suggested he may want to get quotes from contractor, add room count to permit
|
ELE11-02080
| Electrical Rough-In | 9/15/2011 | 9/16/2011 | 9/16/2011 8:40:24 AM | A | PASS |
|
|
Warren Phone #: ###-#### corrections made, ri ok walls only
|
ELE11-02128
| Rough-In Permanent Service | 9/15/2011 | 9/16/2011 | 9/16/2011 8:39:05 AM | A | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by kevin blackmon called, left correction notice, NEC 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing member, 334.30 shall secure nm within 12" of panel, 334.23 shall protect cable within 6' of attic access, 210.52(A)(2) shall provide receptacle in 2' wall in dining room, BCC shall provide box for receptacle in bath
|
ELE10-02470
| ELE-Aging Inspection | 9/16/2011 | 9/16/2011 | 9/16/2011 6:10:25 AM | | DONE |
|
|
see final
|
ELE10-02470
| Final | 9/16/2011 | 9/16/2011 | 9/16/2011 6:10:12 AM | A | PASS |
|
|
ok final
|
ESC11-00466
| Aging Inspection | 9/16/2011 | 9/16/2011 | | | |
|
|
|