Inspections for the day of: Friday, September 16, 2011.
Number of inspections: 19
Percentage of inspections complete: 95 %
Percentage of inspections not complete: 5 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-01773 Final9/16/20119/16/20119/16/2011 2:58:38 PMPPASS
Please give me half an hour notice to insure access Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman ok final
ELE11-01718 Final9/15/20119/16/20119/16/2011 2:57:57 PMPPASS
Phone #: ###-#### >> Inspection requested via web by steve sellers ok final
ELE11-02128 Rough-In Permanent Service9/16/20119/16/20119/16/2011 2:56:28 PMPPASS
>> Inspection requested via mobile web by Kevin corrections made, ri ok, p/s u/g n ok
ELE11-01547 Final9/15/20119/16/20119/16/2011 2:11:57 PMPPASS
Please Call Eli Dorsey at ###-#### and he will meet you there! Have a fantastic day! Phone #: ###-#### >> Inspection requested via web by Kevin Perez ok final, signed card
ELE11-01383 Electrical Rough-In9/15/20119/16/20119/16/2011 1:22:38 PMPCANC
ceiling inspection for cover. Phone #: ###-#### >> Inspection requested via web by steve sellers met contractor, called wrong day, wanted Monday
ELE11-01135 Electrical Rough-In9/16/20119/16/20119/16/2011 12:47:33 PMPFAIL
Ceiling inspection Phone #: ###-#### >> Inspection requested via web by Zane Robertson met contractor, shall remove all lv wiring not used per NEC 725.25
ELE11-01868 Final9/16/20119/16/20119/16/2011 12:28:18 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson ok final
ELE11-02124 Rough-In Permanent Service9/15/20119/16/20119/16/2011 11:55:21 AMAPASS
New home Phone #: ###-#### >> Inspection requested via web by TOM BICAND ri ok, p/s u/g n okI
ELE11-01773 Final9/16/20119/16/20119/16/2011 11:18:24 AMPCANC
Please give me half an hour notice to insure access Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman Inspection cancelled from web by: Shaun Kirkman
ELE11-02127 Permanent Service9/15/20119/16/20119/16/2011 10:43:45 AMACANC
Tony (or owner Paul ###-####) Phone #: ###-#### see conference
ELE11-02112 Electrical Rough-In9/15/20119/16/20119/16/2011 10:32:03 AMAPASS
Entry way addition rough Phone #: ###-#### >> Inspection requested via web by Barbara Szurgot ri ok
ELE11-01752 Final9/15/20119/16/20119/16/2011 10:07:17 AMAFAIL
Rocky or ###-#### Phone #: ###-#### called, NEC 110.16 shall provide workspace about equipment, close openings in panels, correct polarity for receptacle front window
ELE08-02423 Final9/15/20119/16/20119/16/2011 9:46:21 AMAPART
Building 3 Floors 1-4 Phone #: ###-#### >> Inspection requested via web by Sean DeLacy common and rooms part finalled, shall see after tenants make modifications, east side
ELE11-02127 Conference9/16/20119/16/20119/16/2011 8:43:48 AMADONE
talked to owner about service, re-wiring parts of inside, must move service as it is about 12" from fence, suggested he may want to get quotes from contractor, add room count to permit
ELE11-02080 Electrical Rough-In9/15/20119/16/20119/16/2011 8:40:24 AMAPASS
Warren Phone #: ###-#### corrections made, ri ok walls only
ELE11-02128 Rough-In Permanent Service9/15/20119/16/20119/16/2011 8:39:05 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by kevin blackmon called, left correction notice, NEC 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing member, 334.30 shall secure nm within 12" of panel, 334.23 shall protect cable within 6' of attic access, 210.52(A)(2) shall provide receptacle in 2' wall in dining room, BCC shall provide box for receptacle in bath
ELE10-02470 ELE-Aging Inspection9/16/20119/16/20119/16/2011 6:10:25 AM DONE
see final
ELE10-02470 Final9/16/20119/16/20119/16/2011 6:10:12 AMAPASS
ok final
ESC11-00466 Aging Inspection9/16/20119/16/2011