Inspections for the day of: Monday, September 16, 2013.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-02207 Electrical Rough-In9/16/20139/16/20139/16/2013 2:41:23 PMPPART
Partial underground Phone #: ###-#### >> Inspection requested via web by Lars Johnson u/g from transformer to building only looked ok
ELE13-02555 Rough-In Permanent Service9/16/20139/16/20139/16/2013 2:21:05 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Neal Rumsey ri ok, p/s u/g n ok
ELE13-02556 Electrical Rough-In9/16/20139/16/20139/16/2013 1:44:24 PMPPASS
Need an ok to cover underground raceways. Call John for questions. ###-#### Phone #: ###-#### >> Inspection requested via web by John Edwards ok cover u/g ony
ELE13-01476 Electrical Rough-In9/16/20139/16/20139/16/2013 12:55:37 PMPPASS
Max Phone #: ###-#### 1st floor walls only ok cover
ELE13-02016 Rough-In Permanent Service9/16/20139/16/20139/16/2013 12:07:40 PMPNR
rough-in inspection and permanent service inspection.
Electricians will be at job-site until mid afternoon. Call Carlos for any questions at ###-#### Phone #: ###-#### >> Inspection requested via web by David Mackey met electrician, asked to recall for am, still wiring switches and receptacles, needs nailplates, strapping
ELE13-02424 Rough-In Permanent Service9/13/20139/16/20139/16/2013 10:26:27 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Bob Glenn ri ok, p/s u/g n ok
ELE13-02531 Temporary Service9/13/20139/16/20139/16/2013 10:05:14 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Bob Glenn t/s u/g n ok
ELE13-02532 Temporary Service9/13/20139/16/20139/16/2013 9:53:08 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Bob Glenn t/s u/g n ok
ELE13-02539 Electrical Rough-In9/13/20139/16/20139/16/2013 9:32:37 AMAPASS
Please call for access Phone #: ###-#### >> Inspection requested via web by Dan Rohl ri ok
ELE13-02539 Final9/16/20139/16/20139/16/2013 9:32:12 AMAPASS
Please call for access Phone #: ###-#### >> Inspection requested via web by Dan Rohl ok final
ELE13-02545 Final9/15/20139/16/20139/16/2013 9:10:51 AMAPASS
Everything is on the outside of the house home owner should be there Phone #: ###-#### >> Inspection requested via web by Jay Symonds ok final
ELE13-02545 Electrical Rough-In9/16/20139/16/20139/16/2013 9:10:35 AMAPASS
Everything is on the outside of the house home owner should be there Phone #: ###-#### >> Inspection requested via web by Jay Symonds ri ok under tub
ELE13-02541 Electrical Rough-In9/13/20139/16/20139/16/2013 8:49:29 AMAPASS
Lock box #2244 Phone #: ###-#### >> Inspection requested via web by Matthew White ri ok
ELE13-02070 Rough-In Permanent Service9/13/20139/16/20139/16/2013 8:33:42 AMAFAIL
Mucho Phone #: ###-#### called contractor, shall staple nm over panel, use proper tool to crimp ground wires, protect cable within 6' of attic access, provide floor boxes for sliding window