Inspections for the day of: Friday, September 16, 2016.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE16-02857 Electrical Rough-In9/16/20169/16/20169/16/2016 2:12:09 PMPPART
Partial wall cover rough in Phone #: ###-#### Inspection requested via web by Ryan Wake Walls only OK to cover. NO PANEL WALL
ELE16-02987 Permanent Service9/16/20169/16/20169/16/2016 2:05:39 PMPPASS
JR-office Phone #: ###-#### p/s o/h rec ok
ELE16-02106 Final9/15/20169/16/20169/16/2016 1:29:08 PMPPASS
Call when in route if possible; obtain visitors badge from front desk. Phone #: ###-#### Inspection requested via web by Steve McCloy Final ok
ELE16-02648 Electrical Rough-In9/16/20169/16/20169/16/2016 12:47:04 PMPPASS
Jeramie Phone #: ###-#### up beds and back patio ok to cover
ELE16-01009 Final9/15/20169/16/20169/16/2016 12:29:54 PMPPASS
builder mentioned to me that he was able to talk to the building inspector about the can lights in the soffit, he was suppose to contact you about this. If he has not please let me know Phone #: ###-#### Inspection requested via web by Neal Rumsey Correction made final ok
ELE16-01009 Electrical Rough-In9/16/20169/16/20169/16/2016 12:29:32 PMPPASS
builder mentioned to me that he was able to talk to the building inspector about the can lights in the soffit, he was suppose to contact you about this. If he has not please let me know Phone #: ###-#### Inspection requested via web by Neal Rumsey Soffit ok to cover as per Phil Shearer
ELE16-02144 Final9/16/20169/16/20169/16/2016 11:49:18 AMPFAIL
Phone #: ###-#### Inspection requested via web by Darryn Coburn 210.8 A all receps within 6ft of sink shall have GFCI protection.Washer recep 210.12 A Dwelling unit bedrooms shall have afci protectiion. Bonus rm
ELE16-02846 Rough-In Permanent Service9/16/20169/16/20169/16/2016 11:43:24 AMPFAIL
Phone #: ###-#### Inspection requested via web by Barbara Szurgot 314.16 Box fill. 3 single gang Kitchen, cook top and family rm. 320.23 A Cable ran in accessable attic with in 6ft of scuttle hole shall be protected by gaurd strips
ELE16-02968 Temporary Service9/16/20169/16/20169/16/2016 11:10:58 AMPPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk t/s u/g n ok
ELE16-02565 Temporary Service9/16/20169/16/20169/16/2016 11:08:17 AMPPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk t/s u/g n ok
ELE16-02898 Rough-In Permanent Service9/15/20169/16/20169/16/2016 10:56:12 AMAPASS
Phone #: ###-#### Inspection requested via web by David Nelson Corrections made rough in ok p/s u/g n ok
ELE16-03004 Temporary Service9/15/20169/16/20169/16/2016 10:50:31 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
ELE16-03003 Temporary Service9/15/20169/16/20169/16/2016 10:50:05 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
ELE16-03002 Temporary Service9/15/20169/16/20169/16/2016 10:49:41 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
ELE16-02900 Rough-In Permanent Service9/16/20169/16/20169/16/2016 10:41:44 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn rough in ok p/s u/g n ok