ELE19-03397
| Final | 9/15/2019 | 9/16/2019 | 9/16/2019 3:22:44 PM | P | PASS |
|
|
please call half hour ahead Tamera ###-#### code south door 6066# Phone #: ###-#### Inspection requested via web by Barbara Szurgot No changes to walls, just refinishing, all wiring associated items noted fished in. Final ok
|
ELE19-00602
| Electrical Rough-In | 9/16/2019 | 9/16/2019 | 9/16/2019 3:00:14 PM | P | PASS |
|
|
Garage stairwell. Danny is the contact Phone #: ###-#### Inspection requested via web by Buster Bowen Levels 3 to 4 South East stair wall rough in ok cover
|
ELE19-00601
| Electrical Rough-In | 9/16/2019 | 9/16/2019 | 9/16/2019 2:58:55 PM | P | PASS |
|
|
Podium deck hotel side. Danny is the contact. Phone #: ###-#### Inspection requested via web by Buster Bowen Area noted over pool. pour noted rough in ok cover.
|
ELE19-03174
| Conference | 9/16/2019 | 9/16/2019 | 9/16/2019 2:12:41 PM | P | DONE |
|
|
Phone #: ###-#### Inspection requested via web by Jeremy Cloud Discussed if a GFCI device is allowed behind an appliance with wheels. If appliance is easily moved GFCI device is ok behind appliance. Also width of work space required for a panel board. As per 110.26(A)(2) a minimum of 30" or width of equipment is required. Lighting control panel mounted of left wall does not affect work space width of panel in question.
|
ELE19-03479
| Electrical Rough-In | 9/16/2019 | 9/16/2019 | 9/16/2019 1:30:13 PM | P | PASS |
|
|
listing inspection for solar equipment
Please call the installer on your way out - We want to make sure we are there ya!!
Call Logan 208.761.4280 We are doing service calls all day and won''t go to that site to finish the install until you''ve seen it.
Thanks guys Phone #: ###-#### Inspection requested via web by Ryan King 20 amp over current required per drawing. listing confirmed. Rough in ok
|
ELE19-03348
| Final | 9/13/2019 | 9/16/2019 | 9/16/2019 10:14:34 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Kevin Perez 422.31- A disconnecting means shall be provided for all appliances. 110.25 lockouts acceptable. Brkr 32 right panel.
|
ELE19-03424
| Rough-In Permanent Service | 9/13/2019 | 9/16/2019 | 9/16/2019 9:32:22 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Tyler Ridley Service only.... p/s o/h n ok
|
ELE19-02836
| Permanent Service | 9/13/2019 | 9/16/2019 | 9/16/2019 9:08:42 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Angela Stears p/s u/g rec ok
|
ELE19-02836
| Electrical Rough-In | 9/16/2019 | 9/16/2019 | 9/16/2019 9:08:20 AM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Angela Stears 300.5- Underground from pedistal to under mobile home shall be 18" deep to top of conduit minimum. Chasis bond complete.
|
ELE19-03475
| Temporary Service | 9/15/2019 | 9/16/2019 | 9/16/2019 9:01:06 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Dylan Pierce t/s u/g n ok
|
ELE19-02529
| Final | 9/13/2019 | 9/16/2019 | 9/16/2019 8:22:32 AM | A | PASS |
|
|
Replace two wall signs with new signs reading Extra Mile. All Primary power to remain as is. Phone #: ###-#### Inspection requested via web by Ken Olsen Final ok
|