Inspections for the day of: Friday, September 17, 2004.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Johnson
TitlePLM-INSPECTOR
Phone #794-9476
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM04-02071 Plumbing Rough-in9/16/20049/17/20049/17/2004 12:00:00 AMAPASS
mike; Phone #: ###-#### Internet Inspection Request from: Barbara Moore in wall rough-in test ok ok to cover 9/17/2004 10:06:35 AM
PLM04-02716 Water and/or Sewer9/16/20049/17/20049/17/2004 12:00:00 AMAFAIL
###-####- shannon water line need to provide test on both water lines 9/17/2004 10:09:52 AM
PLM04-02716 Sprinkler (Final)9/16/20049/17/20049/17/2004 12:00:00 AMAFAIL
shannon ###-#### need to remove stop and waste valve and repipe with approved shut off and drain valve 9/17/2004 10:08:47 AM
PLM04-02717 Plumbing Rough-in9/16/20049/17/20049/17/2004 12:00:00 AMAPASS
late am please////###-#### mike
PLM04-02683 Water and/or Sewer9/16/20049/17/20049/17/2004 12:00:00 AMAFAIL
Scheduled by a contractor via Hello! on 9/16/2004 at 4:03:27 PM. Contact: ###-####. need to repipe interceptor with pvc and provide first chamber vent and down stream vent to be done by licensed plumber also need to pull sewer tap permit and have inspection by public works will also need to camera sewer line from interceptor to manhole will need to provid backflow pervention for water out to building talked to excavator from big bite excavation on job site will recall when ready 9/17/2004 12:21:58 PM
PLM04-02665 Water and/or Sewer9/17/20049/17/20049/17/2004 12:00:00 AMAPASS
PLM04-01976 Sprinkler (Final)9/17/20049/17/20049/17/2004 12:00:00 AMPFAIL
karen; Phone #: ###-#### Internet Inspection Request from: Darla Downs need to removeall 100 psi piping and repipe with approved material talked to home owner will recall when ready 9/17/2004 1:53:12 PM
PLM04-02437 Final9/17/20049/17/20049/17/2004 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 9/17/2004 at 8:55:59 AM. Contact: ###-####.
PLM04-02488 Plumbing Rough-in9/17/20049/17/20049/17/2004 12:00:00 AMPPASS
Randy --as late as possible.; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
PLM04-01574 Water and/or Sewer9/17/20049/17/20049/17/2004 12:00:00 AMPNR
not ready 9/17/2004 3:40:51 PM
PLM04-02609 Plumbing Rough-in9/17/20049/17/20049/17/2004 12:00:00 AMPPART
main building rough-in complete 9/17/2004 3:48:56 PM
PLM04-02469 Water and/or Sewer9/16/20049/17/20049/17/2004 12:00:00 AMPPASS
mike; Phone #: ###-#### Internet Inspection Request from: Barbara Moore water line to building 10 test ok note water line to building 11 test ok 9/17/2004 3:15:17 PM
PLM04-02348 Water and/or Sewer9/16/20049/17/20049/17/2004 12:00:00 AMPPASS
mike\\water only; Phone #: ###-#### Internet Inspection Request from: Barbara Moore water line test ok 9/17/2004 3:15:41 PM