BLD07-03206
| BLD-Aging Inspection | 9/17/2008 | 9/17/2008 | 9/18/2008 11:29:57 AM | | NR |
|
|
|
MIS08-00021
| MIS-Aging Inspection | 9/17/2008 | 9/17/2008 | 9/17/2008 5:04:49 PM | | CANC |
|
|
|
MIS08-00021
| DOC - Permit Expired | 9/17/2008 | 9/17/2008 | 9/17/2008 5:04:45 PM | P | PASS |
|
|
Permit has expired. No insp. called in.
|
ESC08-00776
| Random Inspection | 9/17/2008 | 9/17/2008 | 9/17/2008 4:39:17 PM | P | PART |
|
|
ESC permit sign posted. After tree removal, remainder of lot will need to be waddeled. Also noted to excavating contractor that some sort of soil stabelization will need to be done on lot.
|
BLD08-01967
| BLD-Final | 9/17/2008 | 9/17/2008 | 9/17/2008 4:32:02 PM | P | PART |
|
|
phil Phone #: ###-#### Note: please call 1/2 hr prior to inspection. Needs to clean up remaining tree debries. Due to homeowner keeping the same floor plan, the terrain in some places could posibly pose a hazard to bystandards, therfore a fence will be put in front of lot. see esc permit.
|
BLD08-01538
| BLD-Final | 9/17/2008 | 9/17/2008 | 9/17/2008 4:14:01 PM | P | PASS |
|
|
Andy Phone #: ###-####
|
BLD08-01538
| DOC - Permit Finaled | 9/17/2008 | 9/17/2008 | 9/17/2008 4:13:56 PM | P | PASS |
|
|
|
ESC08-00610
| Site Final | 9/17/2008 | 9/17/2008 | 9/17/2008 4:07:59 PM | P | PASS |
|
|
|
ESC08-00349
| Random Inspection | 9/17/2008 | 9/17/2008 | 9/17/2008 3:01:14 PM | P | PASS |
|
|
|
BLD08-00856
| BLD-Framing/Rough-in | 9/17/2008 | 9/17/2008 | 9/17/2008 3:00:49 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Gary Beck
|
ESC08-00084
| Random Inspection | 9/17/2008 | 9/17/2008 | 9/17/2008 2:38:46 PM | P | PASS |
|
|
ESC permit sign was posted. general site conditions looked good.
|
BLD08-00234
| BLD-Wall cover | 9/16/2008 | 9/17/2008 | 9/17/2008 2:14:09 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 9/16/2008 at 5:30:10 PM. Contact: ###-####. Verified vapor barrier at 2nd floor ceiling, north half. ok to cover.
|
BLD08-00515
| BLD-Final | 9/16/2008 | 9/17/2008 | 9/17/2008 1:47:37 PM | P | FAIL |
|
|
Ron Phone #: ###-####. Step from front door and backdoor exceeds te 7.75 inch max from top of thresh hold to conc. patio. Also needs to provide insul. certificate.
|
ESC08-00191
| Site Final | 9/17/2008 | 9/17/2008 | 9/17/2008 1:46:07 PM | P | PASS |
|
|
Site is clean. BMP's removed. entire site has been landscaped. 70% reveg ok.
|
BLD08-01853
| BLD-Framing/Rough-in | 9/16/2008 | 9/17/2008 | 9/17/2008 11:27:54 AM | A | PASS |
|
|
Jack Phone #: ###-####. Intrior framed walls only.
|
ESC08-00512
| BMP Violation | 9/17/2008 | 9/17/2008 | 9/17/2008 10:59:40 AM | A | PART |
|
|
Notified RP via verbal c/n to provide containment for dirt pile in north parking lot.
|
BLD08-01168
| BLD-Framing/Rough-in | 9/16/2008 | 9/17/2008 | 9/17/2008 10:58:46 AM | A | PART |
|
|
jerry Phone #: ###-####. 1st. floor interior framed walls only. No grid or hardlids. Also gave contrctor c/n to have architect provide a listed aproved assembly for 3hr. exterior loading dock wall. Existing wall is hallow core precast conc. wall. Assembly submitted was for a solid conc. wall.
|
BLD08-00847
| BLD-Final | 9/16/2008 | 9/17/2008 | 9/17/2008 10:11:13 AM | A | NR |
|
|
Phone #: ###-####. Needs finals from other trades first.
|
ESC08-00757
| Site Preparation | 9/17/2008 | 9/17/2008 | 9/17/2008 9:58:40 AM | A | PASS |
|
|
ESC permit sign posted. Site was clean. All excavations are being contained in backyard.
|
BLD08-01922
| BLD-Footing | 9/16/2008 | 9/17/2008 | 9/17/2008 9:57:55 AM | A | PASS |
|
|
Mike Phone #: ###-####
|
ESC08-00464
| Random Inspection | 9/17/2008 | 9/17/2008 | 9/17/2008 9:37:10 AM | A | PART |
|
|
Informed RP via verbal c/n that controlled north entry point needs additional top dressing and needs to sweep trackout.
|
BLD08-01127
| BLD-Footing | 9/16/2008 | 9/17/2008 | 9/17/2008 9:36:00 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 9/16/2008 at 5:12:50 PM. Stemwall on gridline G between grids 5 -8.5.
|