Inspections for the day of: Monday, September 17, 2012.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-02316 Final9/17/20129/17/20129/17/2012 4:13:00 PMPCANC
Temp pole Phone #: ###-#### >> Inspection requested via web by TOM BICANDI
ELE12-02316 Temporary Service9/17/20129/17/20129/17/2012 4:12:48 PMPPASS
t/s u/g n ok
ELE12-01611 Final9/14/20129/17/20129/17/2012 4:00:58 PMPPASS
Inspect after 3:00pm school in session Phone #: ###-#### >> Inspection requested via web by fred lopez final ok
ELE12-02269 Electrical Rough-In9/17/20129/17/20129/17/2012 2:28:45 PMPFAIL
For wall rough-in only. Phone #: ###-#### >> Inspection requested via web by Chad McKibben Grounding not complete in metal boxes. NEC 330.12(1) where subject to physical damage 1 1/4 MC inside 2x4 stud 330.30(B) support within 12 in. of device or fixture box
ELE12-02297 Electrical Rough-In9/14/20129/17/20129/17/2012 1:52:27 PMPPASS
Phone #: ###-#### >> Inspection requested via web by ERIC CENTERS rough-in ok cover
ELE12-02304 Electrical Rough-In9/17/20129/17/20129/17/2012 1:20:38 PMPPASS
mike Phone #: ###-#### rough-in ok cover cans in covered walkway
ELE12-02220 Temporary Service9/17/20129/17/20129/17/2012 12:58:31 PMPPASS
Temp pole Phone #: ###-#### >> Inspection requested via web by TOM BICANDI t/s o/h n ok
ELE12-02308 Rough-In Permanent Service9/15/20129/17/20129/17/2012 12:30:20 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson rough-in p/s u/g n ok
ELE12-02314 Conference9/14/20129/17/20129/17/2012 10:20:28 AMAPASS
Timothy Phone #: ###-#### Discussed with home owner GFCI W/R receptacles on outside of house.ok
GCE12-00133 GCE-Final9/14/20129/17/20129/17/2012 9:37:11 AMAPASS
Scott @ ###-#### xt. 13 final ok
ELE12-02311 Temporary Service9/14/20129/17/20129/17/2012 8:57:30 AMAPASS
THANKS, BOB Phone #: ###-#### >> Inspection requested via web by Bob Glenn t/s u/g n ok
ELE12-01895 Final9/17/20129/17/20129/17/2012 8:39:52 AMANR
Ryan is on site. Phone #: ###-#### >> Inspection requested via web by Buster Bowen