ELE06-02111
| ELE-Aging Inspection | 9/18/2006 | 9/18/2006 | 9/20/2006 7:51:42 AM | | DONE |
|
|
|
ELE06-03473
| Electrical Rough-In | 9/18/2006 | 9/18/2006 | 9/19/2006 1:06:46 PM | P | PASS |
|
|
Work performed by Aaron White.; Phone #: ###-#### Internet Inspection Request from: Matt Santacruz ok
|
ELE06-00460
| Electrical Rough-In | 9/18/2006 | 9/18/2006 | 9/19/2006 10:48:26 AM | P | PART |
|
|
duke; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley walls front entry elevator equip rm
|
ELE06-03477
| Conference | 9/18/2006 | 9/18/2006 | 9/18/2006 4:35:22 PM | P | DONE |
|
|
HANS ###-#### ok
|
ELE06-03382
| Conference | 9/18/2006 | 9/18/2006 | 9/18/2006 3:29:23 PM | P | DONE |
|
|
ok
|
ELE06-03393
| Permanent Service | 9/18/2006 | 9/18/2006 | 9/18/2006 2:50:45 PM | P | PASS |
|
|
p/s o/h new ok
|
ELE06-03393
| Rough-In Permanent Service | 9/18/2006 | 9/18/2006 | 9/18/2006 2:50:01 PM | P | FAIL |
|
|
jack ; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corr. called 300.4 (A)(1) still needs nail plates for holes where holes are less than 11/4" from edges of framing members as code noted states see added p/s
|
ELE06-03194
| Rough-In Permanent Service | 9/18/2006 | 9/18/2006 | 9/18/2006 2:06:03 PM | P | PART |
|
|
Scheduled by a contractor via Hello! on 9/18/2006 at 7:53:01 AM. Contact: ###-####. makeup ok
|
ELE06-02207
| Final | 9/18/2006 | 9/18/2006 | 9/18/2006 1:53:42 PM | P | FAIL |
|
|
ted; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley corr. not made, 410.8 (A) needs clearence from storage space MB closet
|
ELE06-03439
| Permanent Service | 9/18/2006 | 9/18/2006 | 9/18/2006 1:35:24 PM | P | PASS |
|
|
stu; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley p/s o/h rec. ok
|
ELE06-02491
| Final | 9/15/2006 | 9/18/2006 | 9/18/2006 9:54:49 AM | A | FAIL |
|
|
terry; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corr. fee due called left message, 110.3)B) shall follow manufactures instructions , p/s disconnect olny service rated if manufactures neutral kit is used, xformer shall be grd as 250.30 states, 250.52(A)(1) shall bond all piping together so it is electrically continuous, BCC shall not use romex for commercial work
|
ELE06-02976
| Electrical Rough-In | 9/15/2006 | 9/18/2006 | 9/18/2006 9:21:20 AM | A | FAIL |
|
|
sergey; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles all violations not corrected and new one created, also not ready, 300.4 nail plates, 314.16 box fill, still needs calculations for circuits for new addition and service, 110.14(B) shall use approved tool for crimps loose equip grds told owner if corrections not made we will have to secure contractor
|
ELE06-03453
| Temporary Service | 9/16/2006 | 9/18/2006 | 9/18/2006 8:38:59 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: kendall bender t/s u/g new ok
|
ELE06-01930
| Final | 9/15/2006 | 9/18/2006 | 9/18/2006 8:14:36 AM | A | PASS |
|
|
bill; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok
|